Skip to main content

Archive

Show more

How to Choose and Test Cooling Water for Diesel Genset





When the diesel engine is working, the water level in the radiator will gradually decrease due to the evaporation of the water. Therefore, the water level in the radiator should be checked before starting and when the starting time is long. If it is lower than the drain pipe, Replenish clean soft water. If it is hard water, it should be softened first.







When the diesel engine is used under the environmental conditions below 0 °C, the cooling water should be prevented from freezing to avoid being freezing and cracking of the parts. Therefore, the cooling water should be drained whenever the diesel engine is finished running. For models with closed-loop cooling system, anti-freeze coolant with appropriate freezing point can be used according to the local minimum ambient temperature. Commonly used coolants include ethylene glycol plus water and alcohol, and glycerin plus water. The corresponding formula is shown in the table below for your reference.

 When using flammable antifreeze coolant, it is flammable due to ethylene glycol, alcohol and glycerin. Before using the antifreeze coolant, the diesel engine should clean the dirt in the cooling system to avoid new chemical deposits and affect the cooling effect. For diesel engines that use antifreeze coolant, it is not necessary to release the coolant after each stop, but it is necessary to periodically replenish and check the composition. Never use 100% antifreeze as a coolant.

If there is too much scale and dirt in the diesel engine cooling system, it can be cleaned with a cleaning solution. The cleaning solution can be prepared from water, soda (Na2CO3) and water glass (Na2SiO3) by adding 40 g of soda and 10 g of water glass per liter of water. When cleaning, the cleaning liquid is poured into the cooling water chamber of the diesel engine, and the running water reaches the outlet water temperature greater than 60 ° C, and the operation continues for about 2 hours to stop, and then the cleaning liquid is discharged. After the diesel engine is cooled, rinse it twice with clean fresh water, drain it and then pour it into the cooling water to start the operation, so that the outlet water temperature reaches 75 °C or more, stop the sewage, and finally fill in the new cooling water.

How to use the diesel cooling water test kit

For diesel engine cooling water, you must choose soft water instead of hard water. 40% antifreeze and 3~5% rust inhibitor (DCA4) can be added to the cooling water. The concentration of the additive must be checked every 500 hours to keep it within the correct range.

 How to use the cooling water test kit

1. When the temperature of the cooling water in the diesel engine is (10-55) °C, unscrew the blockage to discharge the cooling water and fill the semi-plastic cup.

2. Dip the test paper into the collected water sample, stir the water sample, and after 3 to 5 seconds, remove the test paper and shake off the water drops on the paper.

3. Wait 45 seconds until the color of the test strip changes.

4. The test paper of the changed color is compared with the color list label on the storage bottle to calculate the value.

5. The color tone that has become yellowish green is compared with the green indication of the test paper storage bottle to determine the concentration. (The concentration display must be between 33% and 50% in the tonal range).

6. The brown color in the middle of the test strip and the pink color in the lower position represent the concentration of the rust preventive. The appropriate range is to satisfy the values of brown (vertical) and pink (horizontal), and is located in the range of 0.3 to 0.8 in the color list label on the test paper storage bottle. .

7. If it is lower than 0.3, a rust inhibitor (DCA4) should be added; if it is higher than 0.8, 50% of the cooling water should be poured out and fresh cooling water should be refilled. Then adjust to the appropriate concentration.

The coolant must generally be replaced every 6 months, otherwise lime and corrosive deposits will occur, affecting the diesel engine cooling system.

How to soften hard water into cooling water suitable for diesel generator sets

The cooling water used in the diesel generator set should be clean soft water. Soft water refers to water with little minerals, such as rain and snow. Most of the water is commonly used in river water, well water, etc. Before it is softened, it contains a lot of minerals in addition to sediment and other impurities. This water is usually hard water. After the salt water is heated in the cylinder, the mineral will form scale on the water jacket wall. The heat transfer capacity of scale is very poor, its thermal conductivity is 50 times lower than that of brass, and 20 to 30 times lower than that of cast iron. Therefore, the heat of the cylinder and the cylinder head cannot be smoothly transmitted to the cooling water, which easily causes the machine to overheat, even burns the lubricating oil, accelerates the wear of the components such as the cylinder and the piston connecting rod group, thereby reducing the power of the diesel engine. In addition, too much scale can not block the water pipe and the cylinder water channel, making the cooling water circulation difficult.







Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...