Shangchai generator manufacture teach you how to store diesel oil

When you use generator set, whether you worry about storage of diesel oil or not? Do you want to store diesel oil by yourself, but do not know how to store with a right way?
 With the progress of social development, a lot of equipment needs electricity to operate. If the power is cut off, it is bound to have a great impact on many enterprises. So people’s requirement for emergency power and standby power is more and more extensive, but diesel generator set is as a complex and large generator equipment, it is a difficult problem to maintain for many unprofessional persons. Here Shangchai generator manufacture will teach you how to store oil.

Shangchai diesel generator set

Firstly, introducing the merits and demerits of diesel generator set oil storage tank:

1. Iron oil storage tank:
This kind of oil storage tank generally is made by 3mm steel plate. Not easily deformed for a long time, but it will rust about 3 years after used.

2. Stainless steel oil storage tank
It is made by 1.2mm 304 stainless steel. It is not rust, but easily deformed.
So how to store diesel oil storage tank that can increasing utilization of diesel oil storage. It is very strict when choose place to put diesel oil storage tank. Recently, many cases because of diesel tank, all because placing many inflammables and explosives. That increasing the harm of  diesel tank. Need to consider many aspects for the place of diesel tank. Firstly, warehouse address need to quantified through risk analysis, can not affect the surrounding enterprises, mines and residential areas. Should ensure the impact of safety distance and risk on surrounding area within the required standard

3. Storage place and requirement of diesel tank.
Diesel oil is flammable and explosive articles, it is not better to store on place where high temperature or intense light is directly irradiate. Avoid irradiation from high temperature in summer. The last, can not have tinder around, and can not have fire and other fire source.

4. Attentions
Fire caused by diesel oil, explosion accident, that happens from time to time, and it is harmful to human body. To avoid accidents, when use and store diesel oil, must use 4 preventive measures.
To avoid deterioration, during store diesel tank, it is easy to evaporate, oxidize or mix in impurities, gum level is increased. Startup performance of diesel oil becoming poor can accelerate mechanical wear, reduce service life of diesel oil.
Measures:
a. Storage containers and diesel oil barrel should keep clean;
b. To reduce diesel oil contact with fresh air, should hermetically store, reduce unnecessary inversion;
c. Pay attention to sunscreen, cooling and temperature changes.

5. Prevention of fire and explosion
Diesel oil is a combustible material, its vapor will burn and blast when it meets an open fire at 60 degrees Celsius, when store, should pay attention to prevention of fire and explosion.
Measures:
a. No combustibles around the oil tank;
b. Cut off fire source, when loading, unloading and refueling, the flow of fire source and opening fire operation should be controlled, and the barrel lid should not be knocked with iron tools.

6.Electrostatic prevention: 
When storing diesel oil, we should pay attention to anti-static electricity. Diesel oil is also a bad conductor. Therefore, static electricity may be generated by friction during transportation and storage. The increase of static electricity may also lead to spark. Therefore, anti-static electricity and timely static electricity generation are necessary for the storage of diesel oil. Relevant anti-static and static electricity conduction measures must be taken.
Measures:
a. When filling oil into the tank, the pipeline must be inserted into the bottom of the barrel. Static electricity is easily accumulated in the dry air and high temperature season, and the filling speed should be slowed down properly.
b. Do not use plastic barrels to store diesel oil as far as possible, but use iron barrels to store diesel generator oil. 
c. In high temperature and dry season, when engaging in diesel filling operation, try not to wear chemical fiber clothing.
 

7. Regular inspection
Must assign management personnel to supervise diesel oil and inspect the safety of diesel oil, and inspect regularly.


Shangchai diesel generator set
 

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...