Skip to main content

Archive

Show more

Why Diesel Generator Can Be Used As Backup Power Source

According to the experience of various countries in the world on diesel generator sets, the emergence of such market demand peaks is inevitable. This is not only a question of regulating the power supply capacity, but also a possible reason for the safety of the power grid, such as the United States, which appeared in the past few years. Canada's massive blackouts and last year's European blackouts, India's biggest blackout this year, left its 600 million people without electricity. The main reason is not that the power supply is insufficient, but that the power grid cannot bear too much load over the years, causing the power grid to be paralyzed. And after the power outages in the United States and Europe, both stimulated the market to form peak demand for backup generators. This may be a modern version of the diesel generator's alternative power supply.

The reasons why diesel generators can be used as backup power are:

1. The diesel generator set is started as a backup power

The start-up speed of the diesel generator is rapid, generally only takes a few seconds, with full load within 1min of emergency download, and full load within about 5-10min of normal working state, and the steam power unit is generally required from start to full load. 3-4h.

2. Short start-up time

Diesel engine shutdown process is also very short, can frequently start and stop.
So diesel generator sets are very suitable for use as emergency or backup power, and many real estate, schools, hospitals, hotels and hotels are very suitable for using diesel generators as backup power sources.

Nowadays, the application field of the generator is becoming more and more extensive, and its performance is also improved. We all know that the fuel injection nozzle is one of the main equipment of the diesel generator and, after a period of time, there is sometimes a burn-in failure. The following is a brief analysis of the reason why the fuel injection nozzle of the diesel generator is burned.

1. Long idle operation

When the diesel engine runs at idle speed for a long time, because of the low temperature in the cylinder and the insufficient combustion of fuel, it is easy to form carbon deposit on the combustion chamber and the fuel injection nozzle, which makes the working conditions of the fuel injection nozzle deteriorate. Especially in the cold winter climate conditions are more serious. Because of the carbon deposition in the combustion chamber, the heat dissipation is slow, which may cause the nozzle to block or drop oil.
  
2. Fuel injection time is too late

If the fuel injection advance angle is too small, the fuel injection time will be too late and the fuel combustion situation will worsen. If the fuel is not adjusted for a long time, the local high temperature will make the fuel injection nozzle and heat insulation sheath burn and melt.

3. Fuel is not clean

Small particles of impurity in the fuel will wear the needle valve and needle valve body at the fuel injection nozzle, and the severe needle valve will be stuck in the needle valve body. Needle valve lag, fuel can not be fixed, quantitative, rapid injection into the combustion chamber, there will be oil dripping or oil ejection phenomenon. The fuel atomization is not good, the burning speed is decreased, and the combustion time at the fuel injection nozzle is prolonged, which leads to the fuel injection nozzle and the heat insulation sheath burning and melting.
  
4. Improper assembly

If the nozzle insulation sheath is not cleaned and installed, the nozzle head and the insulation sheath have a gap, so that the gas into the gap, resulting in reduced heat insulation and heat dissipation, fuel injector and heat insulation sheath burning melt. If the heat insulation sheath is installed too tight, the injector will produce additional stress. Under the joint action of thermal alternating load and fuel injection high pressure load, the nozzle head will break and the needle valve will get stuck and dripping oil.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...