Reasons and Solutions of Common Faults of Cummins Diesel Engine



As we know, diesel engine is very important for diesel generator set. In generally, engine is not easy to damage or have faults, but when it has faults, this will be a serious problem. When the self-diagnosis system does not output fault codes, it is particularly necessary to rely on operator;s inspection and judgment, to determine the nature of fault and the location of the fault. In this article, Starlight Power will tell you some reasons and solutions of common faults of Cummins diesel engine.

1.Diesel engine starts difficultly or can not start up, a lot of white smoke is discharged from the exhaust pipe.

When the engine starts, the exhaust pipe discharges a lot of white smoke, in generally it is not a fault of the fuel supply system.

The reason:
A.There is water in diesel oil. Water evaporates into steam in cylinder and is discharged from exhaust pipe.
B.Cylinder head bolt becomes less crowded or air cylinder gasket washout, so that cooling water gets into the cylinder
C.There is trachoma or crack somewhere in the cylinder block or cylinder head. Water enters the cylinder and evaporates and discharges.

Methods of resolution:

A.Approaching the outlet of exhaust muffler by hand, if there are droplets of water in the wet hands, it is confirmed that water enters the cylinder.
B.Check whether there is water in diesel fuel or not. Check whether there is a large amount of water in the oil-water separator or not, if there is a large amount of water, the fuel quality is poor. First of all, the water in the high and low pressure oil pipeline should be removed; then, the discharging screw plug of the tank should be opened to discharge the water in the tank; finally, the tank should be washed with clean diesel oil.

C.Open the water tank cover, press the starter button while observing whether there is bubbles on the water surface of the nozzle. If there is water in the oil or bubbles on the water surface of the nozzle, the cooling water enters the cylinder.
D.Further look for the specific leak location, can aerate into the tank, pressure is not more than 200 kPa, open the oil pan, inspect the leak at the bottom of the engine; then open the cylinder head to inspect the bottom of the cylinder head and the cylinder gasket and inspect the fault location. For the parts leaking in the directional cylinder, the method of replacement repair or replacement of new assembly is adopted.

2.Diesel engine is difficult to start up in hot tart
The engine is good in cool tart, but after starting a while, the temperature rises, then quenching, it is difficult to start again.

The reason:
It is mainly caused by serious wear and tear of plunger pair and needle valve pair of fuel injection pump. When the engine starts in hot tart, because the temperature of the fuel injection pump and fuel filter is higher, the fuel viscosity decreases, and the starting speed is lower, most of the diesel oil leaks from the wear gap, resulting the starting oil is insufficient to start.

Methods of resolution:
When the plunger pair or needle valve pair is seriously worn out, should replace new product after checking and debugging of the injection pump test bench.

3.There is crackle on cylinder block and cover or the cover leaks water

This will seriously affect the service life of the engine, so should check clearly for this fault.
The reason:
A.Causing seep through because of unsuitable operating. For example, adds cooling water into the engine when in high temperature, or when the engine starts in severe winter, suddenly adds high temperature water into it, or does not use antifreeze and rust-proof fluid according to the regulations, which causes cylinder block and cylinder head to burst, or causes cracks in expansion and extrusion water plug, resulting in corrosion of water plug cover and leakage of cavitation corrosion.

B.Insufficient disassembly and repair. Having not tight cylinder head bolts in the prescribed order, method and moment, causing uneven force or cracks in cylinder block and cylinder head caused by impact; or inadequate installation and deflection when replacing water plug cap.
C.If sand holes and aging treatment is solved unsuitable, concentration of thermal stress or large residual stress in casting, will cause leakage of cylinder block and head.

Methods of resolution:
A.Check whether there are cracks in the cylinder block or head, or the leaking part of a water plug cap. The pressure test of cooling system can be carried out by using the water pressure of 280kPa to 390kPa, found out the crack location. Different repair methods are adopted for different parts.

B.Welding repair can be used when the crack is located near the combustion chamber and valve seat where the temperature is high and the stress is large.

C.Can use epoxy resin bonding to repair the cracks when the temperature is not high and the stress is not high.

D.If there are many small cracks clustered together or small loopholes in the parts with little stress, can use patching method to repair them.

E.When find water blocking cover is corrosion and leakage, it is better to change all water blocking cover as new one. When replacing, pay attention to check whether there are cracks in the fold corner of the water plug cap. If there are cracks, it should not be installed.

After any of the above repairs, should check again to confirm that no leakage, then can install. If there is no repair condition and technical level, new parts should be replaced.

4.Maintenance method of screw hole slide wire of cylinder block
The reason:
The fastening bolt is too hard.
Torque is too large.
Repeated disassembly and assembly resulted in excessive wear and tear.
Improper operation during installation.

Methods of resolution:
If there is much excessive slippage or wear on screw hole of cylinder block, can be repaired by inlay method: expand the damaged screw hole appropriately, then tap out the thread according to the requirement and load the bolt with the outer thread sleeve.

Starlight Power Cummins diesel generator set power range is 26KW to 2400KW

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...