Skip to main content

Archive

Show more

The Engine Power for 90kw-120kw Marine Diesel Generator Set


People who work and live at sea, electricity for their life and equipment on board all is powered by marine generator set , while the power of generator set comes from engine. It can be said that a good engine for power generation guarantees the logistics work at sea.
At the same time, about working environment of engine, there is some difference between engine of marine power generator set and engine of genset for land use. At sea, in working environment with high salt and humidity, not only needs to test the strength and corrosion resistance of the engine block, but also the assembly technology level of the engine. Any defect will lead to the engine can not work properly, which will bring economic losses to users. In addition, because mariners live on board for a long time, they need a silent and low noise engine to guarantee mariners’ work and rest. To guarantee a natural daily life of people at sea, marine generator set will work for a long time, so it is very necessary to have a reliable engine power for generator set. 


The harsh working environment and people's actual needs are all difficult problems for marine generator sets. They are also the test for engines, while Yuchai engine YC6A series can solve all problems once.
YC6A series diesel engines are developed by Yuchai, which using German technology and Japanese marine engine technology.
Yuchai YC6A series engine through long-term market trial, is a mature product with excellent performance and high reliability. The market quantity of YC6A series engine is more than one million. Such model is developed for characteristics of generator set, which is characterized by high cost performance, easy use and maintenance, and superior NVH performance. 

 Technical parameters


 Main characteristics of YC6A series engine:

1. The cylinder block and cylinder head are made of alloy cast iron with high strengthening degree, using integral crankshaft and sliding bearing, small size, light weight and high reliability, and the overhaul period is more than 10,000 hours. Ensure high reliability after years of full verification by market.
2. Use unitary iron casting flesh water cooling jacket exhaust pipe (optional), the cabin temperature is lower and the use is safer.
3. Use necking combustion technology, AD type high pressure oil pump, low inertia small orifice injector, combustion more fully, the fuel consumption index is much better than that of the same power block products in China, and the advantages of supercharger type are more obvious.
4. With Yuchai's exclusive piston ring sealing technology and valve oil sealing technology, the consumption of lubricating oil is 50% lower than that of domestic products of the same power grade. Effectively reduces pistion temperature and ensures the long service life.
5. Advanced and mature electronically-control common rail(BOSCH) and high-efficient turbocharged inter-cooled technologies are equipped with, which ensure precise control of fuel-injection quantity and sufficient air intake; and the full combustion, low fuel consumption and less emission of diesel engine under different load conditions are ensured.
6. Requirements for Grade G3 generator set performance is satisfied.


Yuchai YC6A series engine has excellent quality and technology, it can meet requirement of  working environment with high salt and humidity and guarantee supply electricity for people and equipment at board for a long time, Yuchai YC6A series engine is the ideal power 90-120 kW marine generator set. So that 90-120kw Yuchai marine diesel generator set is suitable for small  fishing vessels and other small vessels. If you are interested Yuchai power generator set for marine use, please contact us directly by sales@dieselgeneratortech.com.

As we know, diesel engine of marine generator set is powered by diesel oil, so when use marine power generator set to create benefits, should also pay attention to the use of diesel oil skills, reasonable use of diesel oil is to protect your beloved diesel generator set
Here Starlight also share some attentions as follows:

1.Guarantee cleaning of diesel oil, before the addition of diesel oil, to go through the full precipitation, sedimentation time preferably more than three days. When refueling, it should also be carefully filtered to prevent mechanical impurities from mixing into diesel oil. In actual operation, it is also necessary to ensure the cleanliness of oil storage containers and refueling tools. This principle is well known to all.
2.Diesel oil with different labels should be mixed properly. Diesel oil with different labels can be blended and used. It can be properly distributed according to different temperature conditions to make full use of fuel resources. It should be noted that the pour point of blended diesel is not the uniform value of the two kinds of labeled diesel oil, but slightly higher than the uniform value of the two kinds of labeled diesel oil.
3.Gasoline must not be mixed into diesel oil , which used in diesel engine of marine generating set. If gasoline exists in diesel oil, the extinguishing performance will be significantly worse, resulting in difficult start-up, so that the diesel generator set can not be started. When gasoline enters the cylinder, it will also wash the smooth oil film of the cylinder and accelerate the wear of the cylinder.
4.Should select diesel oil as well as possible, when choosing diesel oil, we should try our best to select high-grade or first-grade products with sulfur content less than 0.2% and 0.5% , respectively to reduce the corrosiveness of diesel oil.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...