Introduction of Full Copper Brushless Generator

There are many brands of generators on the market. Because the materials are different, the price difference of generators is very large. When customers choose diesel generator sets as backup power, should choose full copper brushless generator, some bad manufacturers use semi-copper semi-aluminum or aluminum wire generators to directly sell to the customer. Before purchasing, the customer must ask supplier the material of the generator. Why should we choose a full copper brushless generator?

Briefly, the movement of the generator is mainly used for electrical conduction, and the conductivity of the metal material is better. Let's take a look at the reference value of metal conductivity:

Silver: 100%; copper: 99%; gold: 76%; iron 74%

From these values we can conclude that silver and copper are more suitable for electrical conduction. But the price of silver is relatively high, so copper is the perfect movement for the generator. Therefore, in selecting the alternator, Starlight Power recommends that customers choose a full copper alternator.

Conductive materials used as wires and cables are usually copper and aluminum (rich in the earth's crust, low price, good electrical conductivity, good metallability). The conductivity of copper is high and the resistivity of 50°C: 0.0206Ω·mm2/m for copper and 0.035Ω·mm2/m for aluminum. When the current-carrying capacity is the same, the cross section of the aluminum wire is about 1.5 times that of copper. The copper core loss is relatively low, the mechanical properties of the copper material are better than that of the aluminum material, and the ductility is good, which is convenient for processing and installation. The fatigue resistance is about 1.7 times that of aluminum.


full copper brushless generator

How to detect if the generator is all copper or half copper?

1. The most accurate and direct way is to dismantle the generator to see the stator coil. After disassembling, divide the alternator into several points. Use a sharp blade to scrape off the insulating paint on the surface of the enameled wire. Look at the color of the metal: the purple color is the copper wire, the silvery white is an aluminum wire. After testing, it is best to cover with insulating paint to enhance insulation.
2. Another method is to measure the DC resistance of the stator coil with a bridge. The resistivity of copper is less than that of aluminum. The copper winding of the generator of the same power is smaller than that of aluminum winding.
3. The physical properties of aluminum are not easy to pull as thin as copper wire, so the aluminum wire of the same power is slightly thicker; because the resistance of aluminum wire of the same cross-sectional area is higher than that of copper wire, to obtain the same current, it is bound to increase the cross-sectional area of aluminum wire, that is, the diameter is large.
Common generators are full copper brushless generators, semi-copper semi-aluminum generators, and aluminum wire generators.

The difference between the copper wire generator and the aluminum wire generator

1. The all-copper generator is more durable. Aluminum has a greater resistant than copper, and the heat generated during use is relatively high, so it is easy to burn out the generator. Moreover, the welding of aluminum and copper can not be naturally integrated, and the connection point of the power line is also easily burned out, resulting in the whole life of aluminum wire generator being much lower than that of pure copper wire generator.
2. Pure copper wire generators are more energy efficient. The resistance of circuit component is proportional to the amount of heat generated, and the resistance is large and the heat is large.
3. The pure copper core generator is quieter. For every 3 dB increase in noise, the noise energy is doubled. The aluminum wire generator is 7 dB higher than that of copper wire generator, so the aluminum wire generator noise is more than twice that of the copper wire alternator.
In addition, the factors affecting the price of diesel generator sets are also related to whether the generator is brushless or brushed. The  full copper brushless generator is significantly more expensive than brush generator.

So what is the difference between a brushless generator and a brush generator in a diesel generator set?


Disadvantage of brushless generator:
1. large friction, large loss;
2. large heating, short life;
3. low efficiency, low output power.
Advantage of brushless generator
1. no brush, low interference;
2. low noise, smooth operation;
3. long life, low maintenance cost.
It is decided that the price of the diesel generator set is not only the brand, but also the material of the generator. The cost of the copper wire generator is higher than that of the aluminum wire generator. The quality of the brushless generator is better than that of the brush generator. Therefore, for the same configuration, the unit price of full copper brushless generator is relatively high.

All Starlight generators adopt all-copper brushless generators. We provide Stamford, Marathon, CSIC Siemens, ENGGA, Leroy-Somer, and Shanghai KEPU brushless generators matching for diesel generator sets.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...