What Is Circuit Breaker of Diesel Generators

Circuit breaker is a switching device, under its action, diesel generator set can turn on, load and break the current which is under normal and abnormal circuit conditions within a specified time.

Circuit breakers are divided into high-voltage circuit breakers and low-voltage circuit breakers according to their scope of use. But the demarcation line between high and low voltage is relatively vague. Generally speaking, the voltage more than 3kV is called high-voltage electrical appliances. Low voltage circuit breaker is also called automatic switch, commonly known as "air circuit switch". It is a kind of electric appliance that can not only switch manually, but also protect electricical equipment. 

Ricardo generators

Diesel generator automatic air circuit breaker is a low-voltage automatic switching device, which is usually used in circuits with AC voltage below 500V. In normal operation, it is used to turn on or break the main circuit; in abnormal operation, it is used to protect the main circuit from overload, short circuit and undervoltage, and automatically cut off the circuit. And after breaking the fault current, there is no need to change parts.

Distribution output of diesel generator set is through circuit breaker. Circuit breaker can protect the alternator of generating unit from being damaged by overload current or other abnormal impact. Circuit breaker has high breaking ability and automatic tripping ability. Users can directly draw power cable from the lower end of the circuit breaker to load when conducting power connection.

In a word, the function of a circuit breaker is control action and protective action.

Control function: input or remove part of power equipment or lines according to operation requirements.
Protective action: when the power equipment or line fails, the breaker is acted on by relay protection and automatic device, and the fault part is removed quickly from the power grid to ensure the normal operation of the non-fault part of the power grid.

There are some requirements for circuit breakers:
1.Circuit Breakers should be able to work reliably for a long time under rated conditions.
2.Sufficient short circuit capability should be included.
Since the grid voltage is relatively reliable and the current is large, when the circuit breaker is disconnected, a strong arc is generated between the contacts, and the circuit can be opened only when the arc is completely extinguished. Therefore, circuit breakers are required to have sufficient short-circuit capacity, especially in the case of short-circuit faults, they should be able to reliably cut off short-circuit current, and ensure sufficient thermal stability and dynamic stability.
3.The shortest possible start time should be included.
When a short-circuit fault occurs in the power grid, the circuit breaker is required to quickly cut off the fault circuit, which can shorten the fault time of the power grid and reduce the short-circuit current damage to short-term equipment.
4.Simple structure and low price.
When safety and reliability are required, economics should also be considered. Therefore, the circuit breaker should be simple in structure, small in size, light in weight, and low in price.

The types of circuit breaker:
China air circuit breakers have device type, universal type, fast type and current limit type, etc., commonly used device type is DZ10 series automatic air circuit breaker, universal type DW94, DW95, DW98 and other models, as well as DZ10 automatic air circuit breaker.

Besides, maybe circuit breaker has faults during working. There are two kinds of common faults in circuit breaker of diesel generators:
1.Circuit breaker automatic trip.
Solution: the diesel generator set overload or short circuit trips. If the circuit breaker occurs fault, we need to maintain or replace it.
2.The circuit breaker cannot be closed.
Solution: the breaker handle can only be closed after it has been disconnected. For parallel control, not synchronized, cannot be closed. It is the fault of circuit breaker, we need to maintain and replace it.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...