The Ways to Maintain Lubricating system of Emergency Diesel Generator

We know Lubricating system is very important for emergency diesel generator. But few people know how to maintain it. Today Starlight Power summarize the methods for you.

How to maintain lubricating oil system of emergency diesel generator set?
1.Select suitable engine oil for emergency diesel generator.
Generally speaking, the instruction manual of each generator set specifies the type of lubricating oil used for the unit. If there is no lubricating oil specified in the manual, the lubricating oil of similar brand can be used. Never mix different brands of engine oil.
2.During the use of emergency generator set, often check the quality of lubricating oil.
Check the mechanical admixture in the engine oil when the engine is hot, and pull out the engine oil scale to check.

emergency diesel generator

Why should the oil level be suitable?
The oil level of the diesel generator set shall be checked before starting each time to ensure that the oil level is within the specified range.
1.Low oil level will causes over wear, tile burning and cylinder pulling.
2.High oil level will cause oil leaking into cylinder, combustion chamber carbon deposit, piston ring binding and blue smoke from exhaust.
Therefore, when the oil in crankcase is insufficient, add it to the specified oil level and find out the reason for the lack of oil. When the oil level is too high, check whether there is water and fuel in the engine oil, find out the cause and solve it. When adding oil, use a cleaning funnel with a filter screen to prevent impurities from entering the crankcase and affecting the normal operation of the generator set.

Why should oil pressure of diesel generator be suitable?
When starting the unit to rated speed or middle speed, the oil pressure should rise to the specific value within 1min. If oil pressure can not reach to the specific value, we should find out the reason to adjust pressure to the specific value.

Check engine oil quality during the use of emergency diesel generator
1.Inspection of mechanical admixture. Check the mechanical impurities in the engine oil of the generator set when the engine is hot (at this time,impurities floating in the engine oil). When checking, draw out the oil scale and observe at the bright place. If small particles is found on the oil scale or the scribe on the oil scale can’t be seen clearly, it indicates there are many impurities in engine oil. Besides, we also can twist engine oil to check whether there are particles, to confirm if the oil can be used. If the oil appears black or there are too many impurities, change the oil and clean the oil filter.

2.Inspection of oil viscosity. The accurate method is to use viscometer to measure. But the more commonly used method is: put the engine oil on the finger and twist it, if there is viscosity feeling, and there is drawstring phenomenon, it indicates that the engine oil viscosity is suitable. If not, it indicates that the engine oil viscosity is poor. We should find out the reason and replace engine oil.

Clean lubricating system and change oil regularly
1.The engine oil filter shall be cleaned regularly; the engine oil basin and oil passage shall be cleaned when the engine oil is changed.
2.Cleaning method:
Drain the oil when the engine is hot, so as to remove the impurities in the oil basin, oil passage and oil filter as much as possible. Replay the mixed oil in the oil basin (15% ~ 20% kerosene, or mix according to the proportion of diesel oil: oil = 9:1), the quantity is 60% ~ 70% of the capacity of the lubrication system. Run the diesel engine at low speed for 5 to 8 minutes (oil pressure above 0.5kgf/cm2), then shut down, drain the mixed oil, clean the oil filter, filter screen, oil radiator and crankcase, and add new oil.

Starlight Power not only provides genset technical support, but also supplies 20-3000kw prime/emergency/standby electric generators. Contact us by email sales@dieselgeneratortech.com directly, we will answer your question and guide you to choose the suitable genset.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...