What Causes Fuel Atomization of 200kw Generator Poor

When the fuel injector of 200kw generator set works, it must have a good atomization function, so as to ensure the fuel combustion of the genset is good, the smoke color of the unit is normal, and the power of the generator is normal.

But maybe we meet fuel atomization of the injector is poor, why? Today Starlight tells you the reasons.

The process of dispersing fuel into fine particles is called fuel spray (or atomization). That can greatly increase the surface area of fuel evaporation and the chance of fuel and oxygen contact to achieve rapid mixing. There are many factors that affect the characteristics of the fuel spray, mainly is structure and size of fuel injector, injection pressure, back pressure of compressed air in cylinder, fuel pump cam contour and speed, fuel viscosity etc.

1.Back pressure of compressed air in cylinder
When Back pressure of compressed air in cylinder of 200kw generator set increasing, density of compressed air will increase, which can increase air resistance acting on fuel spray. Therefore, fuel atomization can be improved, spray cone angle is increased, and range is reduced. In the non supercharged diesel generator, the reverse pressure of the compressed air in the cylinder does not change much, so it has no significant effect on the characteristics of the oil spray.

200kw generator set

2.Fuel pump cam contour and speed
When the cam contour is steep or the camshaft speed is high, the speed of fuel supply in plunger of injection pump will increase. Because injector orifice reduces expenditure, fuel can not folw out directly. Which causes fuel pressure in fuel pipe increased and the speed at which fuel flows out of the orifice increased. Therefore, fuel spray and spray cone angle increases.
3.Fuel viscosity
When the viscosity of the fuel increases, the fuel particles are not easy to disperse into fine drops, resulting in poor atomization. Therefore, for high-speed diesel generators, we generally select light diesel oil with low viscosity as fuel oil.
4.Structure and size of fuel injector
Different structure of injector, the internal perturbation of oil spray will be different, which produce different types of oil spray. The fuel bunches should be closely matched with the combustion system. Different combustion modes require different oil spray, so the fuel injectors with different structures are used.
Under the conditions of unchanged injection pressure, back pressure of compressed air in cylinder and the total size of injector hole, to increase the quantity of injector hole, as the diameter of each orifice decreases, fuel will be throttled more when it flows out of the orifice. So the disturbance increases in the orifice. Therefore, the quality of atomization is improved. If diameter of each orifice increases, the core of the oil spray is dense and the range is increased.
5.Injection pressure
The bigger injection pressure, the bigger initial speed of fuel outflow. Degree of fuel disturbance in the injector hole is bigger, and resistance of compressed air after fuel flow out injector hole, so that the fineness and uniformity of atomization are improved, that is a good quality  atomization. When injection pressure increases, range of oil spray will increase.

How to maintain injector of 200kw diesel generator set?
In order to make the fuel injected into the cylinder by the injector burn completely in time, the oil supply time of the oil pump must be checked regularly. If the fuel supply time is too early, the unit will have difficulties in starting and knocking fault. If fuel supply time is too late, it will lead to black smoke from exhaust, high temperature and increased fuel consumption. The fitting accuracy of the injector needle valve is very high, and the orifice diameter is very small, so we must select specific diesel oil by seasonal variation. Otherwise, the fuel injector can not operate normally.

Do not collide with other hard objects or drop them to the ground when cleaning the needle valve parts of the fuel injector to avoid damaged. When replace the needle valve parts of the fuel injector, should immerse the new coupling in 80℃ hot diesel oil for about 10s. After antirust oil is fully dissolved, spasm the needle valve back and forth in the valve body in clean diesel oil, and thoroughly clean it. In this way, the failure of sticking needle valve due to the dissolving of antirust oil can be avoided.

Above information is about the reasons of fuel atomization poor in 200kw diesel generator set, hope it is helpful to you. When you meet the problem, you can check and remove faults by above reasons.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),