Skip to main content

Archive

Show more

The Correct Use Skills of Wrench for Perkins Generator Set Maintenance

Maybe we are relatively familiar with wrench. It is an indispensable tool for maintenance of Perkins diesel generator set. For the maintenance of diesel generator set, wrench is also needed when necessary, but for the maintenance of generator set, how to use it correctly, Starlight Power generator manufacturer will answer for you.

There are four kinds of wrenches in common use: open wrench, ring wrench, adjustable wrench and socket wrench.

1.Open wrench.
Open wrenches are often used on bolts with narrow mechanical range of motion. Because its handle and head keep a certain angle (15 ° ~ 45 °), which increasing the distance of machining activity. Therefore, the turning speed can be increased, and the contact with the nut is also convenient. It can be sleeved up and down or inserted directly.

The commonly used open wrench is double end open. Its specification is indicated by the opening of the head. Wrench with different opening width is used for turning hexagon nuts or bolts of different specifications. The specifications of commonly used open-end wrenches (mm × mm) are 6 x 7, 8 x 10, 9 x 11, 10 x 12, 11 x 13, 12 x 14, 13 x 15, 14 x 17, 17 x 19, 19 x 22, 22 x 24, 24 x 27, 27 x 30 and 30 x 32, etc.

 Perkins generator set

2.Double offset ring wrench.
Double offset ring wrench is characterized by a large change angle, which is used for disassembling some screws with a small rotation angle at one time. The handle part of the wrench is longer, and the wrench is more convenient. Its specification is the same as the open wrench, and it is also divided according to the opening of the head. The common specifications are the same as those of the open wrench.

The advantages of open wrench and ring wrench are reliable use and can bear large torque. Its disadvantage is that a wrench can only be used on two specifications of nuts or bolts, and its versatility is poor.

3.Adjustable wrench.
The adjustable wrench is composed of a moving plate lip, a plate mouth, a fixed plate lip, a worm gear, a handle and a shaft pin. Adjustable wrench is the most widely used spanner. When it is used, its opening can be adjusted according to the size of nut. It does not need to change spanner frequently, so it has strong adaptability. When encountering irregular nut, it can play a more important role.

Its specifications are divided according to its full length. The commonly used specifications (mm) are 100, 150, 200, 250, 300, 375, 400 and 600, etc., and its largest opening width is 14mm, 19mm, 24mm, 30mm, 36mm, 46mm, 55mm and 65mm, etc. Mechanical repairmen usually use adjustable spanners below 300 mm.

When using the adjustable wrench, use the worm gear 4 to adjust the size of the spanner opening, so that the spanner can tightly clamp the nut, not too loose, otherwise the outer edge of the nut will be damaged. When screwing the larger nut, hold it close to the end of handle. When tightening the smaller nut, hold the handle. Because the required torque is not big, the hand is reliable, and the worm gear can be adjusted at any time, so that the pull lip shrinks to prevent slipping. 

Adjustable wrench can not be used by reversed way. That is to say, the pull lip shall not be used as the force bearing surface, the steel pipe extension handle shall not be used to exert a larger torque, or the adjustable wrench shall not be used as a hammer. In addition, hold the spanner correctly, and make sure that the arm is at a right angle to the wrench body (this angle is the effective angle for turning the spanner).

4.Socket wrench.
Socket wrenches are also commonly used in screws with narrow mechanical range or special concealment, and can be adjusted freely. The utility model is composed of a variety of sockets of different sizes and a spanner handle (movable spanner handle, joint, universal joint head, ratchet handle, torque wrench, etc.) suitable for assembling and disassembling screws at different parts.

Socket wrench is usually installed in a special iron box, each part has its own fixed position, easy to use. Among them, the torque wrench is an indispensable tool in the generator repair work.

Hope the article is helpful to you. More details can be read on the Perkins diesel generator maintenance manual.

Starlight Power manufacturer is the OEM supplier of Perkins diesel engine for generator set in China, Perkins generator set power range is from 25kva to 3125kva, if you have purchase plan, please contact us by sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...