The way to use cut file for generator set maintenance

When we maintain diesel generator set, need many tools, such as cut file. So how to correctly use the cut file? And what should we pay attention to? Today Starlight manufacturer analyze it for you.

When the user repairs the diesel generator set, he uses a file to cut the workpiece surface, to make the workpiece reach the required size, shape and surface roughness, this processing is called file cutting. The highest filing accuracy is 0.01Mmm, and the finest surface roughness is about Ra0.8μm. File cutting has a wide range of work. It can file the inner and outer surfaces of workpieces, and repair individual parts during assembly, etc. 

How to use cut file tool for generator set maintenance correctly?
Firstly, learn to choose a suitable cut file. 
The choice of cut file thickness depends on the size of machining allowance, machining accuracy, surface roughness and material properties. Rough cut file is suitable for filing workpieces with large machining allowance, rough surface and low machining accuracy requirements. A fine cut file is the opposite. The choice of the fine cut file shape depends on the shape of the workpiece surface.

Secondly, learn how to use the file correctly, as follows:
1.File cutting on flat surface.
a.Forward file cutting method. It is a method of filing the workpiece in the same direction. After filing, you can get straight file marks, which are neat and beautiful. It is suitable for final filing and flat surface with small filing size.

b.Cross file cutting method. It files the workpiece from two cross directions. When filing, the contact surface between the file and the workpiece increases, and the file is easy to grasp and stable. The height of the filing surface can also be judged from the filing mark, so it is easy to file the flat surface. However, before finishing the filing on the plane, it is necessary to use the forward filing method to make the filing marks become straight.

c.Push file cutting method. It holds the file horizontally symmetrically with two hands and pushes the file with the thumb, file cut along the length of the workpiece. This method is only suitable for filing long and narrow plane and correcting size.

When filing plane, it is often necessary to check its flatness. It can be checked with steel ruler or knife edge ruler by light transmission method. The degree of unevenness can be judged from the light, shade and strength of light transmission at the gap in the longitudinal, transverse and diagonal directions.

 Cummins diesel generator set

2.Filing method of curved surface.
a.Filing method of outer arc surface. When the margin is not large, the method of filing along the arc is generally adopted. When the file moves forward, it should also swing around the center of the workpiece arc. This method is suitable for rough machining of circular arc surface. However, when the machining allowance is large, the method of cross arc file can be used. According to the requirements of the arc, first file it into a polygon, and then file it into an arc by following the arc.

b.Filing method of inner arc. When filing, the file should complete three movements at the same time :forward movement; Move left and right, about half to one file diameter (half to one file width for half round files); Rotate around the center line of the file. Only when these three movements are carried out at the same time can the internal arc surface be filed well.

The correct use of the file will help users to improve the efficiency of the maintenance of diesel generator set. Have you learned how to use the above files?

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...