We are OEM supplier of Shangchai diesel engine of generator set in China. Prime power capacity 50kw diesel generator set is produced by Starlight Power.

50KW Shangchai Diesel Generator Set technical specifications
Genset model: XG-50GF
Prime power: 50KW
Standby power: 55KW
Rated current:
Voltage: 230/400V
Speed: 50Hz
Frequency:1500rpm
Power factor: 0.8lag
Diesel engine specification
Model: SC4H95D2
Prime power:62kw
Standby power:68kw
The engine performance is as per GB/T2820.
Ratings are based on GB/T1147.1.
Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power output over 24 hours of operation shall not exceed 80% of the prime power rating.
Standby power is available in the event of a utility power outage or under test conditions for up to 200 hours of operation per year.
The permissible average power output over 24 hours of operation shall not exceed 80% of the standby power rating.
Engine Type: In-line,4 strokes, water-cooled, 4 valves, Turbo charged
Combustion type: Direct injection
Cylinder Type: Dry liner  
Number of cylinders: 4  
Bore × stroke: 105(4.14) × 124(4.89) mm(in.)
Displacement 4.3(262.4) lit.(in3)
Compression ratio: 17.3 : 1
Firing order 1-3-4-2
Injection timing 13.5°BTDC
Dry weight: Approx. 450kg (992.1 lb)
Injection pump Beiyou in-line “AD” type
Dimension 1012×723×1102 mm  (L×W×H) (39.9×28.5×43.4in.)
Rotation Counter clockwise viewed from Flywheel
Fly wheel housing SAE NO.3
Fly wheel SAE NO.11.5
FUEL SYSTEM
Governor Electric type
Feed pump Mechanical type
Injection nozzle Multi hole type
Opening pressure 250 kg/cm2 (3556 psi)
Fuel filter Full flow, cartridge type
Used fuel Diesel fuel oil
LUBRICATION SYSTEM
Lub. Method: Fully forced pressure feed type
Oil pump Gear type driven by crankshaft
Oil filter Full flow, cartridge type
Oil pan capacity High level 13 liters ( 3.4 gal.)
Low level 11 liters ( 2.9 gal.)
Angularity limit: Front down 25 deg.
Alternator technical specification
Model: Shanghai Kepu TFW2-50 (Brushless self-exciting and single bearing).
Capacity: 62.5KVA
Speed: 50Hz
Connecting Type: Y type connection
Alternator Efficiency: 95%
Protection Level: IP22
Insulation Class, Temperature Rise:H/H
Voltage Regulation, Steady State: ≤±1%
Controller technical specifications
Protection level of control box: IP55
Manufacturer: SmartGen(Zhengzhou) Technology Co.,Ltd.
More details of diesel generator, please contact us by email sherly@dieselgeneratortech.com or WhatsApp: +8613471123683.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz