Skip to main content

Archive

Show more

2000kw 2500kva Yuchai Genset Technical Specifications

We are Starlight Power, a manufacturer of diesel generators in China, founded in 1974. We are not only authorized as diesel engine OEM partner of genset by Cummins, Volvo, Perkins, Deutz, Shangchai, Weichai, Ricardo, but also Yuchai. Starlight series Yuchai generators power range is from 20kw to 3000kw which is with stronger power and good performance. Today we mainly introduce 2000KW generator set powered by Yuchai diesel engine YC16VC3300-D31.


Feature of 2000KW diesel generator set powered by Yuchai engine

The genset has low noise.

High horsepower, low fuel consumption, large torque.

Easy maintenance and low price.


YC16VC series engine is a high-power V-type product independently developed by Yuchai.

Advantages:

1.Compact structure and excellent performance.

2.Energy conservation and environmental protection, reliability and durability.

3.The emission pollutants, power performance, economy and reliability indexes have reached the international advanced level.

Yuchai YC16VC series diesel engine

Type characteristics

1. The engine body is made of high-strength material, arc stiffener grid structure, four bolt main bearing structure, with high rigidity, small vibration and low noise.

2. The crankshaft is made of high-quality alloy steel with all fiber extrusion forging, shaft diameter and fillet quenching heat treatment, anti-wear and long service life.

3. It adopts electronic control single pump, four valve, high efficiency supercharging and intercooling, Yuchai combustion chamber technology, with low fuel consumption, less emissions, excellent speed regulation performance, fast and powerful loading.

4. One cylinder and one cover structure, the side of the engine body is equipped with maintenance window, which is convenient for maintenance.

5. Adopting world-class equipment and production technology, the quality is stable and reliable.

6. Meet the requirements of G3 level of generator set performance.


Genset Controller

Model: SmartGen HGM6120N

 SmartGen HGM6120N

HGM6120N series automatic controller, integrating digital, intelligent and network techniques, is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and three “remote” (remote control, remote measure and remote communication). The controller uses LCD display, optional display interface including Chinese, English, Spanish, Russian, Portuguese, Turkey, Polish and French with easy and reliable operation.

 

Every electric generator of Starlight is strictly tested before delivery, we can provide factory test report. And you do not need to worry about the maintenance, we can provide operation manual, maintenance and repair manual and we can provide guidance. If you want to buy electric generators, welcome to call us +8613481024441.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...