What should we do when using diesel generator controller

Genset controller is mainly used to distribute the electric energy output by the generator to the user's load or electrical equipment, and to indicate the working condition of the diesel generator and to maintain the voltage stability of the generator under the condition of load change.

 

Genset control panel is usually equipped with voltmeter, frequency meter, ammeter, power meter, three-phase current conversion switch, three-phase voltage conversion switch, voltage setting knob and various indicator lights. About oil pressure gauge, oil temperature gauge, battery charging ammeter, water temperature gauge, start button and start electric lock and other components. Some devices are directly installed on the control panel according to the description requirements, and some devices are installed on the external panel of diesel engine. The components of the internal device of the control panel are mainly related to the excitation method of the generator and the active control of the diesel engine.

 

The internal structure of diesel generator set control panel.

The simple control panel is usually equipped with voltage regulator, silicon rectifier diode, rheostat, active air switch and current transformer and other components, while the disordered control panel is equipped with overload and short circuit protection device, electronic governor, silicon controlled rectifier, relay, various safety devices and small transformer and other electrical equipment.

 

diesel genset


The use of diesel generator sets will vary according to the regional differences. The main reason is that the power of the generator has decreased, and the fuel consumption of diesel oil is still increasing, and the heat load is constantly rising. Therefore, we start from the theoretical point of view, and analyze the impact of high original environment on the performance of the generator set according to examples.

 

In plateau area, the air pressure is low, the air is thin, and the air volume containing oxygen is less. For the diesel generator with natural suction, the combustion condition will become worse due to insufficient air intake, so the diesel generator will not send out the original specified rated power. Diesel generators are basically the same, so it can be seen that their working capacity has declined in plateau environment.

 

The output current of generator set will change with the change of altitude, and decrease with the increase of altitude. Besides, fuel consumption index and electrical performance index will be added.

In plateau area, the air pressure is low, the air is thin, and the air volume containing oxygen is less. For the diesel generator with natural suction, the combustion condition will become worse due to insufficient air intake, so the diesel generator will not send out the original specified rated power. Diesel generators are basically the same, so it can be seen that their working capacity has declined in plateau environment.

 

The output current of generator set will change with the change of altitude, and decrease with the increase of altitude. Besides, fuel consumption index and electrical performance index will be added.

 

Due to the high altitude of the plateau, the temperature of the environment is lower than that of the plain, and the air in the plateau is thin, so the starting performance of the diesel engine is relatively poor in the plateau area. Therefore, it is suggested that the user should take corresponding temperature assisted measures when using it.

 

The boiling point of water decreases with the increase of altitude, and the air pressure and quality of cooling air decrease, which increases the increase of heat dissipation. However, since the cooling system is worse than the plain environment, it should be noted that the open cooling cycle should not be used in the plateau altitude area, and the pressurized closed cooling system can be used.

 

After all, there is a great gap between the plateau and the flat land. We must pay attention to it when purchasing and using control panel of diesel generator, otherwise it will have a great impact on the work efficiency and cause certain economic losses.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Silent Cummins 640kw Diesel Generating Sets

Technical data of 800KVA AC diesel generator set The DG Set is skid mounted, directly coupled with Cummins water cooled engine with built in shock absorber for anti vibration. The alternator is Stamford brand with brushless and self excited, with control panel and protection system complete set. Prime power: 640KW/800KVA Standby power:704KW/880KVA Rated voltage: 230/400V Rated current: 1152A Speed/frequency:1500rpm/50Hz ( or 1800rpm/60Hz) Power factory:0.8lag Size: open type genset: 4.2 x1.82x2.25m, silent genset: 6.5 x2.6 x2.78m Net wight: open type genset: 7800kg,   silent genset : 12000kg Technical Data of Diesel Engine Diesel engine brand/model: Chongqing Cummins/ KTA38-G2B( full new) Prime/standby power: 790KW/920KW 4 Stroke Cycle , 60° Vee , 12 Cylinder, Turbocharged &Aftercooled, 1500rpm, 50Hz, bore/stroke: 159/159mm. The Cummins diesel engine is equipped with electronic type governor, over speed shutdown devices to protect against runaway when electronic governor or con...

Guides to Clean VOLVO Diesel Generator Cooling System

VOLVO Engine Cooling System Volvo engine's internal cooling system makes sure the engine works at the right temperature. It is a closed system that must always be filled with a mixture of concentrated coolant and water in order to protect the engine against internal corrosion, cavitation and bursting due to freezing. Coolant of a suitable chemical composition must be used all year round. This also applies in areas where there is never any risk of freezing, to provide the engine of  diesel generator set   with full corrosion protection. The use of anti-corrosion agents alone is not permitted in Volvo Penta engines. Never use water alone as a substitute for coolant. The corrosion protection additives become less effective over time, which means that the coolant must be changed at regular intervals; refer to Maintenance Schedule. The cooling system must be flushed whenever the coolant is changed; Volvo Penta coolants have been prepared to work best ...