Single Generator and Paralleling Generator, Which is Better


Today Starlight Power tells you which is better for  Single Generator and Paralleling Generator.

If your power needs are large enough, you may wonder whether it’s better to go with a single, huge diesel generator, or split the burden between two or more smaller generators. For example, instead of a 1200kW generator, you could install three 400kW generators. This is called paralleling, and it can be a great option in the right circumstances. Here’s why:

#1. Greater flexibility. It’s very likely the reason you’re buying a generator at all is the additional reliability, a hedge against an interrupted power supply causing a slowdown or halt to your business’s operations. With multiple generators, you don’t have to worry if one has to be shut down for maintenance. You simply shift the burden to the others and keep right on working.


With just one generator, if it has to stop, so do you.

2. Can be more cost-effective. Obviously the economics will vary widely depending on brands, new vs. used generators, prices in your geographic location, etc. But all things being equal, once you breach a certain generator size, it becomes more economical to parallel than use a single unit. Specifically, once you go over the sizes of gas or diesel engines mass-produced for use in cars, as well, those engines are harder to come by and are thus more expensive. And the engine comprises more than half the cost of a generator.

The threshold for diesel engines is 600kW and for gas engines it’s 150kW.

3. Can be more practical. Depending on your physical space, it may be easier to fit two or three parallel generators into a room than one oversized unit. Among large commercial generators, smaller capacities can mean the difference in 25 or more square feet per unit.

4. Easier on the generators. Load sharing among two or more generators can extend the life of each generator and avoid the risk of overburdening a single unit. For continuous usage, loads up to 80% generator capacity are ideal.

 If you have purchase plan of diesel generators, please contact us by email sales@dieselgeneratortech.com or call us by phone +8613481024441 ( same as WeChat).

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...