Faults of 800kw Diesel Generator Set

 

What is a Diesel Generator?

A diesel generator is the combination of a diesel engine with an electric generator (often an alternator) to generate electrical energy.  A diesel compression-ignition engine is designed to run on fuel oil, but some types are adapted for other liquid fuels or natural gas.

Diesel generators are used in places without connection to a mains electricity supply, or as an emergency power-supply if the grid fails.

 


How do Diesel Generators Work?

A diesel generator converts diesel fuel into electricity.  The diesel engine burns diesel fuel in order to produce motion for the generator, which converts the motion into electricity by using electromagnets.

Though a number of fuels can be used to power similar engines, diesel is generally preferred for generators because of its ability to burn but not explode. The fuel tank of the diesel engine is filled, and the engine is started. A throttle and governor are used to keep the speed of the diesel engine consistent in order to control the power output of the generator while also preventing damage to components that could be caused by the engine operating at too high a speed.

As the diesel engine turns the crankshaft that connects to the generator, the central axle of the generator is spun within a chamber containing electromagnets. This high-speed motion causes an electric current to be produced, which is then available for use by any equipment that is plugged in to the diesel generator.

What is an Acoustic Enclosure?

Generators are large, noisy and potentially dangerous, so where they are sited and how they are protected demands special care.   Acoustic enclosures protect the machinery and those who work with it from noise, vibration and the risk of fire. They also offer protection from the weather as well as provide security, safe access and ventilation.

Where can Diesel Generators be Used?

 Portable Generators are usually used for residential purposes to power a few domestic appliances during a power failure or at construction sites that have no source of electrical power required to operate tools.

Commercial Standby / Industrial Generators are used in commercial facilities such as hospitals, offices, manufacturing plants, mining operations, nursing homes, emergency services and data centres.  Anywhere that cannot risk its ability to function being discontinued, due to a power failure, usually has a generator in case of such circumstances.

What is a Diesel Engine?

The diesel engine is a type of internal combustion engine, a compression ignition engine. The fuel in a diesel engine is ignited by suddenly exposing it to the high temperature and pressure of a compressed gas containing oxygen (usually atmospheric air), rather than a separate source of ignition energy (such as a spark plug). This process is known as the diesel cycle after Rudolf Diesel, who invented it in 1892.

Types of Diesel Engines

There are two classes of diesel engines: two-stroke and four-stroke. Most diesel engines generally use the four-stroke cycle, with some larger engines operating on the two-stroke cycle.

What is the difference between kW and kVA?

kW – kilowatt

kVA – kilovolt – ampere

The main difference between these two measurements is the power factor.  kW is real power, while kVA is apparent power (real power + reactive power).  The power factor is typically 0.8, however it can range from 0 to 1.  The kVA will value will always be higher than the kW because it includes the reactive power.

Other than the US and a small number of other countries who use kW, the rest of the world tend to use kVA as the primary value, when referring to generators.

The kW unit rating is the power output a generator can supply based on the horsepower of an engine.  Horsepower is a unit of measure of power (the rate at which work is done) equal to 550 foot-pounds per second.  This is equivalent to 745.7 watts.

For example 1 horsepower = 745.7 watts, therefore a 500 horsepower engine has a kW rating of 372,850.

What is a power factor?

The power factor (pf) is defined as the ratio between real power (kW) and apparent power (kVA).

0.8 (pf) x 1500kVA = 1200kW

The standard power factor for a three phase generator is 0.8.  The pf found on the ID place of a generator relates the kVA to the kW rating.  Bearing in mind that power factors are anything between 0 and 1, generators with a higher power factor are more efficient in transferring energy to the connected load, whereas generators with a lower power factor are not as efficient and result in increased power/fuel costs.

We are a diesel generators manufacturer in Jiangsu China, having focused on diesel generator set for more than 45 years. Welcome to contact us by email sales@dieselgeneratortech.com, we will work with you. 

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Silent Cummins 640kw Diesel Generating Sets

Technical data of 800KVA AC diesel generator set The DG Set is skid mounted, directly coupled with Cummins water cooled engine with built in shock absorber for anti vibration. The alternator is Stamford brand with brushless and self excited, with control panel and protection system complete set. Prime power: 640KW/800KVA Standby power:704KW/880KVA Rated voltage: 230/400V Rated current: 1152A Speed/frequency:1500rpm/50Hz ( or 1800rpm/60Hz) Power factory:0.8lag Size: open type genset: 4.2 x1.82x2.25m, silent genset: 6.5 x2.6 x2.78m Net wight: open type genset: 7800kg,   silent genset : 12000kg Technical Data of Diesel Engine Diesel engine brand/model: Chongqing Cummins/ KTA38-G2B( full new) Prime/standby power: 790KW/920KW 4 Stroke Cycle , 60° Vee , 12 Cylinder, Turbocharged &Aftercooled, 1500rpm, 50Hz, bore/stroke: 159/159mm. The Cummins diesel engine is equipped with electronic type governor, over speed shutdown devices to protect against runaway when electronic governor or con...

Guides to Clean VOLVO Diesel Generator Cooling System

VOLVO Engine Cooling System Volvo engine's internal cooling system makes sure the engine works at the right temperature. It is a closed system that must always be filled with a mixture of concentrated coolant and water in order to protect the engine against internal corrosion, cavitation and bursting due to freezing. Coolant of a suitable chemical composition must be used all year round. This also applies in areas where there is never any risk of freezing, to provide the engine of  diesel generator set   with full corrosion protection. The use of anti-corrosion agents alone is not permitted in Volvo Penta engines. Never use water alone as a substitute for coolant. The corrosion protection additives become less effective over time, which means that the coolant must be changed at regular intervals; refer to Maintenance Schedule. The cooling system must be flushed whenever the coolant is changed; Volvo Penta coolants have been prepared to work best ...