The reasons of Cummins genset start difficulty

 1. Diagnosis and treatment of engine starting difficulty or failure to start and exhaust pipe emitting a large amount of ash and white smoke.
The engine is difficult to start, and the exhaust pipe discharges a large amount of gray smoke, which is diesel vapor.
Reason
a. The engine temperature is too low, diesel oil is not easy to evaporate and burn.
b. Poor atomization of injector
c. The oil supply is too late.
d. The oil supply is too small and the mixture is too lean.
e. Cylinder leakage is too much, compression can not reach the ignition temperature.


Diagnosis and treatment
a. If the Cummins generator engine temperature is too low in cold season, check whether the low temperature starting preheating device fails, that is, whether the preheater control circuit has open circuit, short circuit or preheater failure.
b. If the low temperature preheating device is normal, check whether the injection timing is correct. Turn the engine and insert the engine camshaft timing pin, that is, when it is located at the upper dead center of cylinder compression, check whether the fuel pump camshaft lock pin can be inserted. If it cannot be inserted, it indicates that the injection timing is wrong and needs to be adjusted.
c.The spray quality of each cylinder injector should be checked to meet the requirements.
d. If the first two items are normal, check if the oil supply is too small. During cold start, due to the low temperature in the cylinder, the fuel viscosity is large, and the evaporation condition is poor, the starting oil supply is required to be larger than the rated oil supply.
e. Finally check the cylinder pressure and repair it when the pressure difference is very far.
2. Diagnosis and treatment of engine starting difficulty or failure to start and exhaust pipe emitting a lot of black smoke.
The engine is difficult to start, and the exhaust pipe emits a large amount of black smoke, which is the result of incomplete combustion of the diesel oil.
Reason
a. Diesel oil is of poor quality.
b. The air intake is not smooth and the air filter is blocked.
c. The injection timing adjustment is too early.
d. Injector needle valve sealing is poor, there is dripping oil leakage phenomenon.
e. The injection pressure is too low
f. The fuel supply of the fuel injection pump is too large and the combustion is deteriorated.
g. Low cylinder pressure and poor atomization.
Diagnosis and treatment
a. Determine if the diesel quality meets the requirements.
b. Check if the air filter is clogged.
c. Check if the injection timing is too early. Turn the engine and insert the engine camshaft timing pin, that is, when it is located at the upper dead center of cylinder compression, check whether the fuel pump camshaft lock pin can be inserted. If it cannot be inserted, the fuel injection timing is wrong and needs to be adjusted.
d. Check whether the fuel pump supply is too large.
e. Check if the fuel injection pressure and spray condition of the fuel injector are good, and the fuel injector should not have a dripping phenomenon.
f. The working condition of each cylinder shall be checked by the oil-breaking method.
g. If the above inspection is normal, but the fault remains, check whether the cylinder pressure and piston, piston ring and cylinder clearance are abnormal, whether the cylinder gasket is damaged or the valve is not tightly closed, etc.
3. Diagnosis and treatment of engine thermal starting difficulties
The cold start of the engine is good, but after running for a period of, temperature rises and the engine turns off. It is difficult to start again.
Reason
It is mainly caused by serious wear of plunger pair of fuel injection pump and needle valve pair of fuel injector. When the hot car starts, the fuel viscosity is reduced due to the high temperature of the fuel injection pump and fuel filter, and the starting speed is low, and most of the diesel oil leaks from the worn gap, resulting in insufficient starting oil and unable to start.
Diagnosis and treatment
a. The method of emergency elimination is: the car is hung up and driven by other cars. Using the speed of the car to drive the high-speed rotation of the engine, so that the diesel can not leak, to ensure the starting fuel supply (this method is not recommended, because the cylinder pressure of Cummins supercharged engine is relatively large, the impact force on the connecting parts when the trailer starts is large, affecting the vehicle service life).
b. When the plunger pair or needle valve pair is seriously worn, the new product should be replaced after the inspection and debugging of the fuel injection pump test bench.
 
Starlight Power is manufacturer of 20kw-3000kw diesel generator set, all genset has passed CE and ISO certificate. If you have purchasing plan, welcome to contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...