Skip to main content

Archive

Show more

1300kw Electric Generators Supplied by Starlight Power

Recently, Starlight Power received the notice of winning the bid for 1300KW Yuchai diesel generator set. This generator set is used for real estate project, and Starlight Power will start the loitering work in time within the specified time.

Starlight Power is authorized as OEM supplier of Yuchai engine for diesel generator set with long term stable friendly and cooperative relations. Starlight Yuchai series diesel generator set is with good quality and low price, win a good reputation among users.


 1300KW Yuchai diesel generator


Feature of 1300KW diesel generator set powered by Yuchai engine YC12VC2270-D31

1.YC12VC series engine is a classic product independently developed by Yuchai. It has the advantages of energy saving and environmental protection, excellent performance, compact structure, reliability and durability. The emission of pollutants, power, economy and reliability index have reached the international advanced level.

2.It adopts electronic control unit pump, four valves, high-efficiency supercharging and intercooling, Yuchai combustion chamber technology, low fuel consumption, less emissions, excellent speed regulation performance, fast and powerful loading.

3.The machine body is made of high strength material, arc stiffener grid structure, four bolt main bearing structure, high rigidity, low vibration and low noise.

4.The crankshaft is made of high-quality alloy steel all fiber extrusion forging, shaft diameter and fillet quenching heat treatment, anti-wear and long service life.

5.Adopt the world-class equipment and production technology, stable and reliable quality.

6.One cylinder and one cover structure, maintenance window is opened on the side of the machine body, which is convenient for maintenance.

7.Meet the G3 level requirements of generator set performance.

8.Emission standard meet GB 20891-2014 Stage III.

 

Mains technical datasheet of Yuchai engine model YC12VC2270-D31

Type: Vertical, V-type, water-cooled, four stroke

Air intake mode: Turbocharged & Intercooled

Cylinder number: 12 cylinder

Bore x Stroke: 200x210mm

Prime power: 1520KW

Standby power: 1670KW

Fuel consumption: 195g/kW.h

Engine oil capacity: 340L

Coolant capacity: 300L

Max. water radiator temp.: 102℃

Engine fuel oil rate: ≤ 0.3%

Start mode: Electric start

Governor type: Electric speed control

Start motor: 24V

Start motor power: 11KW

Water pump driving mode: Gear drive

Fuel system: Electric unit pump (direct injection)

 

This 1300KW diesel generator is equipped with Starlight Power brand alternator TFW2-1300-4A. The alternator is produced by Starlight Power, copper is 100%, brushless and self-exciting, with AVR.

 

Of course, Starlight Power also have other alternator brands, such as Stamford, Leroy Somer, ENGGA, Marathon, Siemens, Shanghai kepu, Shanghai Stamford etc. Starlight Power is the OEM supplier of these alternators.

 

Yuchai diesel generator set power range is from 20kw to 2500kw(50Hz/60Hz), other series electric generator: Cummins, Volvo, Perkins, Shangchai, Deutz, Weichai, Doosan, MTU, Tongchai etc. Starlight Power only produces good quality and real product, not produces fake product. All of our product has quality warranty. If you need to purchase, welcome to contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...