Skip to main content

Archive

Show more

50KW Silent Diesel Generator-Starlight Power

 

Recently, Starlight signed a contract of 2 sets of 50KW diesel generator set with Beijing Gu Hong Technology Co., Ltd.


Beijing Gu Hong Technology Co., Ltd. Was set up in 2005. 50KW silent diesel genset purchased the customer is equipped with SDEC( Shangchai) H series diesel engine. The engine is a world-class power platform built by Shangchai company according to the characteristics of market demand at home and abroad, referring to the mature technology of international advanced engine, jointly designed with Ricardo of UK, using CPDP development process and SAIC MOTOR manufacturing standard. This series of engines have the characteristics of compact structure, wide range of power, high reliability, good economy and low vibration and noise. In addition, the generator set is equipped a silent rain proof canopy cabinet, which can be directly  outdoor used, and ensure that the generator set is free from the influence of wind, rain, dust and mosquitoes. More importantly, the noise level can be reached to 65dB at 7 meters.


silent genset

 

Shangchai H series diesel engine technical specification (SDEC SC4H95D2)

1.The engine performance is as per GB/T2820.

2.Ratings are based on GB/T1147.1.

3.Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power output over 24 hours of operation shall not exceed 80% of the prime power rating.

4.Standby power is available in the event of a utility power outage or under test conditions for up to 200 hours of operation per year.

5.The permissible average power output over 24 hours of operation shall not exceed 80% of the standby power rating.


Engine model

SC4H95D2

Prime Power

62KW

Standby power

68KW

Speed

50Hz

Frequency

1500rpm

Engine Type

In-line,4 strokes, water-cooled, 4 valves, Turbo charged

Combustion type

Direct injection

Cylinder Type

Dry liner

Number of cylinders

4

Bore × stroke

105x124mm

Displacement

4.3L

Compression ratio

17.3:1

Firing order

1-3-4-2

Injection timing

13.5°BTDC

Rotation

Counter clockwise viewed from Flywheel

Fly wheel housing

SAE NO.3

Fly wheel

SAE NO.11.5 

Fuel system

Injection pump

Beiyou in-line “AD” type

Governor

Electric type

Feed pump

Mechanical type

Injection nozzle

Multi hole type

Opening pressure

250 kg/cm2

Used fuel

Diesel fuel oil

Lubrication system

Lub. Method

Fully forced pressure feed type

Oil pump

Gear type driven by crankshaft

Oil filter

Full flow, cartridge type

Oil pan capacity

 

High level 13 liters

Low level 11 liters

Cooling system

Cooling method

Fresh water forced circulation

Water capacity(engine only)

6.8L

Water pump Capacity

117L

Thermostat

 

Wax–pellet type

Opening temp. 82°C

Full open temp. 95°C

Cooling fan

Blower type, plastic 550 mm diameter, 9 blades 


Electrical system

Charging generator: 24V×55A

Voltage regulator: Built-in type IC regulator

Starting motor: 24V×4.5kW

Battery Voltage :24V

Battery Capacity : 120 AH

 

Engineering data   

Water flow: 117 liters/min @1500 rpm

Heat rejection to coolant: 11.7 kcal/sec @1500 rpm

Air flow: 5 m3/min @1500 rpm

Exhaust gas flow: 11.5 m3/min @1500 rpm

Exhaust gas temp.: 600 °C @1500 rpm

Max. permissible altitude: 2000m


SDEC diesel generator can be 50kw to 1800kw, if you have purchasing plan, welcome to contact us by email sales@dieselgeneratortech.com, we will work with you at any time.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),