Analysis of Common Faults of Volvo Diesel Generator Sets Pistons

 

The piston is an indispensable part of the Volvo diesel generator set. The reciprocating motion in the cylinder transmits the force and completes the working cycle of the diesel engine; the piston, the cylinder head and the cylinder together form the combustion chamber, and the piston group acts as a seal to prevent the gas from penetrating into the crankcase, but also restricts the oil entering the combustion chamber. This paper studies and analyzes the common failures of pistons in diesel engines to make the pistons operate reasonably, efficiently and reliably.


electric diesel generator


1. Piston skirt wear


When the piston is working normally, its skirt and the piston pin seat hole form a vertical working surface. Due to the action of side pressure, it directly rubs with the cylinder wall, and the surface produces regular filamentous wear marks. In general, this wear does not affect the normal fit of the piston to the cylinder wall. When the piston is working, because it is equipped with a piston ring, its head is rarely in contact with the cylinder wall (the diameter of the head is generally smaller than that of the lower part, the difference is about 0.6-0.9mm), and the top is easy to expand because it is heated and the metal is also thicker. Although the skirt is in contact with the cylinder wall, its unit pressure is not large, and the lubrication conditions are good, so the wear is also small. Due to the side pressure generated when the piston and connecting rod are running at high speed, the piston will form radial wear. Therefore, the measure of the availability of the piston depends on the degree of increased clearance between the piston and the cylinder wall. As a result of the increase in the gap between the piston and the cylinder wall, the metal knocking sound (commonly known as the knocking of the cylinder) aggravates the wear of the piston and the cylinder wall, air leakage, poor start-up, unstable speed, decreased power, increased oil consumption, and exhaust gas blue smoke.


2. Piston ring groove wear


The piston ring of the Volvo diesel generator set moves in the ring groove, so that the piston ring groove is subject to maximum wear in the height direction, making it step-shaped or trapezoidal (large outside and small inside). The influence of the unit pressure and high temperature of the piston ring on the groove wall is the main cause of wear, and the wear speed of the ring groove depends to a large extent on the roughness of the piston ring plane and the structure of the piston. The side clearance and backlash of the piston ring increase, the oil channeling (fuel leaks into the oil basin), the pumping action increases (the oil participates in the combustion, and the exhaust emits blue smoke), the oil consumption increases, and the power and economy decrease.


3. Piston pin seat hole wear


The wear of the piston pin seat hole of Volvo diesel generator set is generally smaller than that of the piston ring groove, and the wear speed depends on the roughness of the piston pin seat hole and the fit of the piston pin and the pin seat hole. Due to the action of gas pressure and inertial force, the wear of the piston pin seat hole is not round, and the largest wear occurs in the direction perpendicular to the piston top (upper and lower of the piston pin seat hole). The fit of the pin hole is loose; the pin rattles; the pin jumps out and breaks the cylinder. In addition, the piston will also produce peripheral wall cracks and scratches and other faults. If the above damage is found, it cannot be used.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How Do You Check Diesel Consumption In The Diesel Generator Set?

  Diesel generator sets   are crucial assets in various industries, providing backup power during outages or serving as primary power sources in remote locations. With fuel costs being a significant operational expense, monitoring diesel consumption becomes essential for efficiency and cost-effectiveness. Here's a comprehensive guide on how to effectively check diesel consumption in a generator set. Understanding Diesel Consumption Metrics Before delving into the monitoring process, it's crucial to grasp the key metrics associated with diesel consumption: Fuel Consumption Rate: This indicates the rate at which diesel is being consumed by the generator set, typically measured in liters per hour (L/hr) or gallons per hour (GPH). Load Factor: The percentage of the generator's maximum capacity being utilized at any given time. It directly influences fuel consumption, with higher loads resulting in increased fuel usage. Fuel Efficiency: A measure of how effectively the generator...