Methods to Reduce Wear of Cummins Generator Set Parts

 

If the parts of Cummins generator set are worn, it will seriously affect its performance and service life, so we must master the correct method to reduce the wear of Cummins generator set parts. Specific actions that can be taken include:


Cummins 250 kw diesel generator


Suitable lubrication method. Choose appropriate lubricants and lubrication methods, and replace dry friction with better fluid friction, which is a way to reduce friction and wear. For Cummins generator set accessories, choose which brand of lubricating oil to use according to the specific requirements of different engines and accessories, as well as according to different seasons and regions of use.


Reasonable structural design. The structure should be conducive to the formation and recovery of the surface protective film between the friction pairs, the uniform distribution of pressure, the dissipation of frictional heat, the discharge of wear debris, and the prevention of the entry of external abrasives and dust. in structural design. The displacement principle can be applied, which allows one fitting in the system to wear out to protect another important fitting, or the transfer principle, which allows the other two pieces in the friction pair to wear out quickly while protecting the valuable fitting.


Select the correct part material and finish. According to the form of basic wear, choose the material correctly to improve the wear resistance of Cummins generator set parts. Materials with high fatigue strength, good corrosion resistance, wear resistance and high temperature resistance should be selected in the design and manufacture. At the same time, attention should be paid to the mutual solubility of the paired materials, so that they have a suitable combination, and the wear resistance of the surface can be improved by using various surface treatment methods.


Improve quality. Improving the quality of machining, assembly and installation is an effective measure to prevent and reduce wear.


Create good environmental conditions and correct use and maintenance. Try to avoid excessive load, high movement speed and working temperature, create good environmental conditions, strengthen scientific management, conduct regular personnel training, and strictly implement operating procedures and other relevant rules and regulations. Cummins generator set parts should be properly run-in at the beginning of use. During use, the maintenance of the oil supply system, air intake system and lubrication system should be done well to prevent the generation and intrusion of abrasives. Use monitoring and testing techniques wherever possible.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz