Skip to main content

Archive

Show more

Methods to Reduce Wear of Cummins Generator Set Parts

 

If the parts of Cummins generator set are worn, it will seriously affect its performance and service life, so we must master the correct method to reduce the wear of Cummins generator set parts. Specific actions that can be taken include:


Cummins 250 kw diesel generator


Suitable lubrication method. Choose appropriate lubricants and lubrication methods, and replace dry friction with better fluid friction, which is a way to reduce friction and wear. For Cummins generator set accessories, choose which brand of lubricating oil to use according to the specific requirements of different engines and accessories, as well as according to different seasons and regions of use.


Reasonable structural design. The structure should be conducive to the formation and recovery of the surface protective film between the friction pairs, the uniform distribution of pressure, the dissipation of frictional heat, the discharge of wear debris, and the prevention of the entry of external abrasives and dust. in structural design. The displacement principle can be applied, which allows one fitting in the system to wear out to protect another important fitting, or the transfer principle, which allows the other two pieces in the friction pair to wear out quickly while protecting the valuable fitting.


Select the correct part material and finish. According to the form of basic wear, choose the material correctly to improve the wear resistance of Cummins generator set parts. Materials with high fatigue strength, good corrosion resistance, wear resistance and high temperature resistance should be selected in the design and manufacture. At the same time, attention should be paid to the mutual solubility of the paired materials, so that they have a suitable combination, and the wear resistance of the surface can be improved by using various surface treatment methods.


Improve quality. Improving the quality of machining, assembly and installation is an effective measure to prevent and reduce wear.


Create good environmental conditions and correct use and maintenance. Try to avoid excessive load, high movement speed and working temperature, create good environmental conditions, strengthen scientific management, conduct regular personnel training, and strictly implement operating procedures and other relevant rules and regulations. Cummins generator set parts should be properly run-in at the beginning of use. During use, the maintenance of the oil supply system, air intake system and lubrication system should be done well to prevent the generation and intrusion of abrasives. Use monitoring and testing techniques wherever possible.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...