Skip to main content

Archive

Show more

Dingbo Power Exported A 30KW Yuchai Diesel Generator to Zimbabwe

 Dingbo Power produced and exported a prime power 30KW open type diesel generator set to Zimbabwe in May, 2024. The genset is powered by Yuchai YC4V55Z-D20 engine and coupled with Shanghai Stamford GR180H alternator. It can provide optimum performance, reliability and versatility for stationary standby and prime power applications.


Features of Yuchai 30KW diesel generator set


Yuchai YC4V55Z-D20 Engine – This diesel engine delivers reliable power with low emission, low fuel consumption, low noise and low vibration. The engine is compact in structure, small in size, light in weight and easy to maintain on one side. When below ambient temperature 45 ℃ and below 1000 meters altitude, 1500 RPM engine operation is able to output rated power.


Shanghai Stamford GR180H alternator – It offers superior motor starting capability with low reactance 2/3 pitch windings. Its self-excitation control provides continuous short-circuit current capability. Class H insulation can withstand harsh environmental conditions.


Control System – Manual start, the controller includes indicators such as current, frequency, voltage, opening and closing.


The generator set is equipped with a 63A circuit breaker, which prevents that the electrical installation suffers overloads and short circuits.


Dingbo Power Exported A 30KW Yuchai Diesel Generator to Zimbabwe


Design considerations of the air flue of a generator room


Generally, open type diesel generator sets are installed in dedicated generator rooms. A well-designed generator room should ensure that ventilation airflow (room inlet airflow) is adequate to reject the heat produced during operation and support the engine combustion process. Therefore, it’s essential to ensure the efficient ventilation of the air inlet/outlet opening during the design process.


This not only helps to provide sufficient air for the combustion process of the unit, but also provide an environment for the maintenance/operation personnel so they can work comfortably. A lot of heat, such as engine heat and alternator heat, is generated during operation, so a reasonable exhaust system can effectively reject the heat and help keep the room temperature close to the ambient temperature.


To ensure proper ventilation, the air inlet/outlet opening should be of suitable dimensions. It’s recommended that the generator room adopts inclined top air intake and set it on one side of the control panel of the diesel genset. Louvers and metal protection net should be installed and fitted to the windows to prevent foreign objects from entering and ensure good air convection. The louver fins should have openings of sufficient dimensions to make sure that air circulation is not being blocked. Otherwise, the occurring backpressure might cause the genset to overheat.


To prevent the return of hot air, keep the distance between the air inlet opening and the air outlet opening of the genset as far as possible, and ensure that the air flow in the generator room is smooth. At the same time, the air intake should be protected to avoid the intrusion of rain and other foreign objects.


When installing exhaust outlets or exhaust shafts with shutters and metal shields, ensure that the net area of the exhaust outlet is at least 1.4 times the effective area of the radiator core. The engine crankcase ventilation should be connected to the front of the radiator via a hose. In this way, oil vapor should be easily discharged from the room to the outside. Precautions should be taken so that rain water does not enter the crankcase ventilation line. Automatic louver systems should be used in applications with gaseous fire extinguishing systems.


Dingbo Power is a professional diesel generator manufacturer, which integrates the design, supply, debugging and maintenance of diesel generator sets. Feel free to contact us for any further information or assistance regarding to generator sets.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Silent Cummins 640kw Diesel Generating Sets

Technical data of 800KVA AC diesel generator set The DG Set is skid mounted, directly coupled with Cummins water cooled engine with built in shock absorber for anti vibration. The alternator is Stamford brand with brushless and self excited, with control panel and protection system complete set. Prime power: 640KW/800KVA Standby power:704KW/880KVA Rated voltage: 230/400V Rated current: 1152A Speed/frequency:1500rpm/50Hz ( or 1800rpm/60Hz) Power factory:0.8lag Size: open type genset: 4.2 x1.82x2.25m, silent genset: 6.5 x2.6 x2.78m Net wight: open type genset: 7800kg,   silent genset : 12000kg Technical Data of Diesel Engine Diesel engine brand/model: Chongqing Cummins/ KTA38-G2B( full new) Prime/standby power: 790KW/920KW 4 Stroke Cycle , 60° Vee , 12 Cylinder, Turbocharged &Aftercooled, 1500rpm, 50Hz, bore/stroke: 159/159mm. The Cummins diesel engine is equipped with electronic type governor, over speed shutdown devices to protect against runaway when electronic governor or con...

Guides to Clean VOLVO Diesel Generator Cooling System

VOLVO Engine Cooling System Volvo engine's internal cooling system makes sure the engine works at the right temperature. It is a closed system that must always be filled with a mixture of concentrated coolant and water in order to protect the engine against internal corrosion, cavitation and bursting due to freezing. Coolant of a suitable chemical composition must be used all year round. This also applies in areas where there is never any risk of freezing, to provide the engine of  diesel generator set   with full corrosion protection. The use of anti-corrosion agents alone is not permitted in Volvo Penta engines. Never use water alone as a substitute for coolant. The corrosion protection additives become less effective over time, which means that the coolant must be changed at regular intervals; refer to Maintenance Schedule. The cooling system must be flushed whenever the coolant is changed; Volvo Penta coolants have been prepared to work best ...