Skip to main content

Archive

Show more

The Function of Fuel Filter in Diesel Generator Set Part 2

 This article continues to introduce the function of diesel filters in diesel generator sets.


standby power generator


The fuel filter of a diesel generator set is mainly composed of three parts: filter element, housing, and filter seat. All models are universal, except for overflow valve 8 which has two structures. C0810A or C0810B filters are selected according to different models. A 12 cylinder V-type diesel generator set is installed in parallel with one C0810A and one C0810B.

 

The fuel is sent from the fuel delivery pump to the fuel filter, where impurities are removed from the fuel through a paper filter element before entering the interior of the fuel filter cartridge, and then passing through the oil collection chamber on the filter seat to the fuel injection pump. The filter seat is equipped with a return joint and an overflow valve. When the fuel pressure inside the fuel filter exceeds 78kPa (0.8kgf/C ㎡), excess fuel is returned to the fuel tank through the return joint. Connect the low-pressure fuel pipeline in the direction indicated by the arrow on the seat, and do not connect it incorrectly. The filter seat is connected to the housing by a pull rod and sealed with a rubber ring. There is a vent plug on the upper end of the filter seat, and users can release the screw to clear the air from the fuel filter during use.

 

The fuel filter of the diesel generator set is fixed to the body or bracket with two M8-6H screws. If the user finds that the fuel supply is not smooth during use, there is a possibility of filter blockage. At this point, the vehicle should be stopped to drain the fuel. You can directly loosen the pull rod nut on the diesel generator set, remove the housing, take out the filter element, and then immerse the filter element in gasoline or diesel to gently wash away the dirt with a brush. If the filter element is broken or difficult to clean, it must be replaced, then installed, and filled with clean fuel.

 

A brief introduction to the typical structure of diesel filters in diesel generator sets by Guangxi Dingbo Electric Power. If during use, it is found that the three precision components of the diesel engine fuel system, especially the plunger pair, are severely worn or the fuel supply is not smooth, it may be caused by a malfunction of the fuel filter, and the problem should be promptly disassembled, inspected, and eliminated.

 

Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...