High Quality 580kw/725kva Cummins Diesel Generator Set

580kw/725kva Cummins diesel generator is supplied by Starlight Power factory, having open type, silent container type, trailer type. Here is the technical specifications for your reference before you purchase. 1.Cummins diesel generator data Prime power: 580KW Standby power: 639KW Engine model: KTA38-GA Alternator: Stamford HCI634G1 Controller: Deep Sea DSE7320 Rated voltage: 400/230V( or as you need) Speed/frequency: 1500rpm/50Hz Power factor: 0.8lag 3 phase & 4 wire Fuel consumption @ 1500rpm: 133L/h (100% prime rated load) Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd. 2. Cummins genset diesel engine KTA38-GA data Manufacturer: Chongqing Cummins Engine Co.,Ltd. Model: KTA38-GA Prime power:647KW Standby power:711KW Speed: 1500rpm Displacement : 38L Bore X Stroke : 159X159mm Compress Ratio:14.5:1 Aspiration: Turbocharged Fuel System: Cummins PT No. of Cylinder : V-12 Governor type: electronic EXHAUST SYSTEM Maximum Allowable Back Pressure (1500rpm): 2.3in.Hg(3...

800kw 1000kva Diesel Genset with Cummins Engine Stamford Alternator

500KW Diesel Generator Bearing Standard-Starlight Power

As we know, bearing is an important part of diesel generator set and has a huge influence on the service life of diesel generator set, so what is the requirements of diesel genset bearing? Starlight Power generator manufacturer answers for you. 1.Bearing ring gear Because transmission accuracy of the bearing is low , and diameter of the ring gear and the module of the gear is bigger, the accuracy level of the gear is generally required to be 9 or 10 in GB / t10095.2-2001. However, due to the influence between the pinion and the   bearing ring gear  in the working state, the tooth surface of the bearing ring gear should be hardened, and the hardness of the pinion tooth surface is generally 60 HRC. Considering the equal life design, the hardening hardness of the gear tooth surface of the large gear is specified as no less than 45 HRC. 2.Clearance Yaw and pitch bearings have special requirements on clearance. Compared with the yaw bearing, the impact load of th...

300kw 375kva Cummins Diesel Generators

How to Stop Diesel Generator Sets Normally?

Starlight Power tell you how to stop the diesel generator set normally. 1. Gradually remove the load, and put all the electrical switches on the stop position, and all the adjustment knobs shall be reset to the corresponding position of stop. 2. After unloading, gradually reduce the speed of the diesel engine to 600r / min, and stop the engine according to the requirements of the instructions for use of the diesel engine. After shutdown, the feed pump shall be started to work for no more than two minutes, so as to supplement lubricating oil and heat dissipation in the high temperature area of the diesel engine. 3. For diesel genset with generator excitation switch, turn the excitation switch to the off position first after unloading, and then reduce the speed of the unit. 4. When the ambient temperature is lower than 5 ℃, the accumulated water in the water tank, water pump and diesel engine cooling system shall be completely drained after shutdown to prevent freezing. Adding antifree...

400kw 500kva Cummins Diesel Generator Set with CE ISO Standard

400KW Yuchai diesel gesnet in generator room

300KW Yuchai Diesel Generator Set Commissioning in Generator Room

The reason of high water temperature of 625kva power generator

During the use of 625kva diesel generator, maybe you meet the problem of high water temperature. What causes it? Here Starlight Power answers for you. 1.We use hard water for diesel genset for a long time. When diesel generator running, there is temperature in the water tank. So the water tank and each size of water pipe will form a lot of scale, resulting in poor heat dissipation. 2.There are too many impurities in the water channel between the generator body and the cylinder head, which makes the water circulation not smooth and causes poor heat dissipation. 3.The generator set burns the engine oil seriously, resulting in excessive carbon deposition and poor heat dissipation.   625kva silent power generator 4.Improper operation and use of diesel generator. When starting the diesel generator, it is necessary to preheat it for a period of time with the medium and small throttle. Do not suddenly increase the throttle and load, otherwise the diesel generator...

63kva water-cooled diesel generator set--Starlight Power

We are OEM supplier of Shangchai diesel engine of generator set in China. Prime power capacity 50kw diesel generator set is produced by Starlight Power. 50KW Shangchai Diesel Generator Set technical specifications Genset model: XG-50GF Prime power: 50KW Standby power: 55KW Rated current: Voltage: 230/400V Speed: 50Hz Frequency:1500rpm Power factor: 0.8lag Diesel engine specification Model: SC4H95D2 Prime power:62kw Standby power:68kw The engine performance is as per GB/T2820. Ratings are based on GB/T1147.1. Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power output over 24 hours of operation shall not exceed 80% of the prime power rating. Standby power is available in the event of a utility power outage or under test conditions for up to 200 hours of operation per year. The permissible average power output over 24 hours of operation shall not exceed 80% of the stand...