The reason of fuel injector pump of genset not supply oil

Electric generator fuel supply and its speed control system mainly includes fuel injection pump, fuel injector, fuel delivery pump and regulator, etc. No matter which of the above components fails, the unit will not work normally. Today Starlight generator manufacturer shares the reason why fuel injection pump not supply oil. Hope it is helpful to you. Why does fuel injection pump of   electric generators   not supply oil? 1.There is no fuel in fuel tank or the oil switch did not open. 2.Fuel filter is blocked up. 3.There is a lot of air in the oil way. 4.Fuel injection pump plunger spring is broken. 5.Excessive wear of plunger coupling (plunger and plunger sleeve). 6.Plunger is stuck. 7.The position of the screw groove of the plunger is wrong. 8.The oil outlet valve is excessively worn or the oil outlet valve is covered with dirt. 9.The plane contact between the oil outlet valve and the plunger sleeve is not tight (if there is any impurity), which causes the diesel to l...

New Genset 120KW Yuchai Power & Generating Sets

150kw Cummins Silent Diesel Generator

We are as a leading manufacturer of diesel generator in Jiangsu China, founded in 1974. Our product has sold all over the world, such as Ethiopia, Egypt, Sri Lanka, Philippines, France etc.   On June 16, 2020, we exported 150KW silent diesel generator set to Nigeria. Before shipment, we do test and commissioning at factory, after all qualified, we deliver the   genset   to client. Thanks for the client’s support.   Feature of 150kw silent diesel generator set 1.Soundproof, waterproof and robust silent case, suitable for all-weather 2.Auto start, auto stop and manual change over switch. 3.Easy to access to all major components during routine maintenance 4.Non-slip flooring 5.Emergency battery backup lighting with manual test switch 6.Low fuel consumption, noise level 75dB@7m 7.Base bottom fuel tank for 8 hours operation   Diesel generator set technical data Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd. Genset model: XG-150GF Prime/standby rating...

New 150KW Silent Diesel Genset Made by Starlight Power

250KW Mobile Diesel Generator Set Made by Starlight Power

How to deal with diesel genset room problem

When selecting the plane position of the machine room for plane layout of the machine room, it should be adjacent to the power transformation and distribution room as much as possible, because it is convenient for wiring, reducing the loss of materials and electric energy, and also convenient for management. If conditions permit, the machine room is preferably located on the first floor, which is convenient for ventilation, heat dissipation and smoke exhaust . Genset in machine room However, in high-rise buildings and large and medium-sized commercial buildings, the first floor is usually used as a commercial house, and the owner generally does not agree with this plan, but often places the machine room in the basement. At this time, the following points should be paid attention to in selecting the location of the machine room: (1) The machine room should have one side against the outer wall, so that the equipment ventilation and smoke exhaust are easier to handle. (2) Attention shall ...

1000kw 1250kva Power Generators with Cummins Engine

Yuchai 200KW Silent Diesel Generator Genset

Safety operation of 640KW diesel genset

It is important to ensure 800kva generator set operate safely when using diesel generator. How to do it? Today Starlight Power answers for you. 1. Check all indicating instruments according to the specified time, and pay attention to the pressure of lubricating oil and whether the water temperature changes. The pressure of lubricating oil and the temperature of cooling water must be within the specified value. 2. Check the crankcase oil level, fuel tank oil level and radiator water level, and make up if it is lower than the normal position. 3. Frequently observe whether the instruments and alarm indicators of the distribution panel are normal. Where the red light is on, it means there is a fault, and the green light is the normal operation indicator. 4. Check whether the charger is charging normally. 5. Listen to whether the operation sound of each part of the unit is normal. 6. Check whether the temperature of the shell of the hand mold body, the shell of the bearing part...