Starlight Power Won The Bid For 2 Non Dynamic Diesel Generator Sets

  Recently, Starlight Power and Nanning Ronghe Chenjing Real Estate Co., Ltd. have successfully signed a 292KW and   580KW non-dynamic diesel generator set   each, both of which are used for emergency backup power supply in the south area of Ronghe Wuxiang Academy. In addition, Starlight Power is also responsible for the smoke exhaust, environmental protection and noise reduction projects of the project. It is understood that since the cooperation between Ronghe Group and Starlight Power in 2012, a total of 24 diesel generator sets have been signed, with a power range of 200KW-800KW.   Guangxi Ronghe Enterprise Group Co., Ltd. was established in 1993 and is headquartered in Nanning, the capital of Guangxi. It is a large-scale private enterprise group mainly engaged in real estate development, including hotels, property management, finance, cultural communication and other industries. The cooperative project Ronghe Wuxiang Academy is located a...

600kw Ricardo Cheap Generators for Sale

Maintenance Requirements for Diesel Generator Bearings

The rotors of diesel generators generally use rolling bearings, which are lubricated with grease. Usually, the universal diesel generator uses ZGN-3 calcium-based grease, and the moist heat type diesel generator uses ZL-3 lithium-based bearing grease. Under normal circumstances, when the diesel generator runs continuously for about 1500h, the grease should be replaced to ensure the normal operation of the   diesel generator . The working quality of the bearing directly affects the operation reliability of the diesel generator, so we should pay attention to maintenance. The intact bearing is measured with a thickness gauge under field conditions. The matching clearance between the inner and outer circles of the bearing and the ball (column) is appropriate, and no shaking can be detected. The appearance of each part is good: no damage, no corrosion, no cracks, good roundness and surface roughness of the rolling contact surface, when holding the inner ring to dial the outer ring, the ...

High Quality New 800kw Generators

Jiangsu Starlight Sold 550kw Electric Generator

  On June 6, 2021, Starlight Power and Beihai Yindu Urbanization Construction Co., Ltd. successfully signed a   550KW Yuchai diesel generator set , which is used for the emergency backup power supply of the 4 plot of the Dadu Jincheng project. In addition, Starlight Power is also responsible for the environmental protection and noise reduction project of the generator room.   It is understood that Beihai Yindu Urbanization Construction Co., Ltd. is a subsidiary of Guangxi Dadu Investment Co., Ltd., and Guangxi Dadu Investment is a diversified investment enterprise focused on real estate development by Guangxi Construction Engineering Group. The Dadu Jincheng project in this cooperation is the second project of Guangxi Construction Engineering and Dadu Investment in Beihai, a new regional benchmark real estate. The project is located at No. 66 Yintan Avenue, Yinhai District, Beihai City, adjacent to Fengjiajiang Wetland Park and mangroves, and 8 minutes away from Beihai Yi...

Starlight Power High Quality Mobile Trailer Diesel Generators 50Hz 60Hz

Starlight Power Successfully Signed 656KW Yuchai Generator Set

  On June 26, Starlight Power and Chengdu Tonganda Logistics Co., Ltd. successfully signed a   656KW Yuchai diesel generator set . The unit is used for emergency backup power supply for plots 1 and 2 of Chengdu Baofeng Jiuzhu Project. In addition, Starlight Power is also responsible for the environmental protection and noise reduction project of the generator room of the project.   It is understood that the Baofeng Jiuzhu project is jointly funded and constructed by Chengdu Tonganda Logistics Co., Ltd. and Chengdu Tonganda Industrial Co., Ltd. It is located at the exit of Sanhechang Station of Chengdu Metro Line 3. The community covers an area of 68 mu, with 30% greening and a plot ratio of 2.8. The project is 100 meters away from the subway entrance and exit of Sanhechang Station, and there are many main roads at the entrance. The project is adjacent to a number of ecological parks and is very livable. There are rich educational resources within 3 kilomete...

What To Look For When Buying A Generator Set?

  Correctly sizing a generator is a key factor in avoiding the loss of efficiency and durability. Finding just the right measurement The initial and most basic step is to define which devices will be connected to the power  generator  and to know the necessary power rating for the project. In other words, to know the total power of all the electrical devices which will need to be powered by the genset, applying simultaneity rates wherever possible and always responding to the client’s requirements and needs. However, a simple mathematical operation will not give us enough information. There are other factors which much be taken into account, for they affect the result of this calculation. They have to do with technical aspects, as well as with usage and environmental ones. It is necessary to have a more thorough control over the greater loads in the installation; electric motors, illumination for discharge lamps or LEDs, are all electrical loads which are difficult to pow...

Requirements for Ventilation and Cooling of Diesel Genset

  The cooling and ventilation of diesel generator set is very important. The machine room shall have sufficient air flow to meet the needs of genset combustion, cooling and ventilation. 1.Cooling requirements 1. When installing diesel generator set , make the radiator close to the exhaust outlet as far as possible to prevent the recirculation of hot air. When there is no air duct, it is recommended that the distance between the radiator and the exhaust outlet should not exceed 150mm. If the machine room is difficult to meet the above requirements, it is recommended to install corresponding air ducts. 2. The area of the air outlet shall be 1.5 times that of the radiator. Generally, the air duct and exhaust louver shall be installed in conjunction with the radiator. 3. The bending of the air duct shall pass through the appropriate elbow. If the pipeline is too long, the size shall be increased to reduce the exhaust back pressure. Long distance air duct silencer shall be specially d...

China Diesel Generator Set Factory-Starlight Power

New 600kVA Yuchai Diesel Genset Testing and Commissioning

What are the Internal Causes of Diesel Generator Set Failure?

  As a   Diesel Generator Manufacturer , share with you. Generators are now more practical power generation equipment, but any mechanical equipment may fail. In order for us to use the generator without affecting the efficiency and normal operation, it is necessary to understand some skills and diagnostic knowledge of the generator set. Generator Sets  Internal reasons 1. The nature of materials and oils In the design and manufacturing process, materials should be selected correctly according to the working nature and characteristics of the generator set parts. Inappropriate selection of materials, non-compliance of materials and selection of inappropriate substitutes are the main reasons for the phenomenon of wear, corrosion, deformation, cracking and aging of the parts. The properties of various materials and oil used in the unit can be summed up in three aspects: physical properties, chemical properties and mechanical properties. Many failures of the unit are due to th...

What are the advantages of mobile trailer generator sets?

  The mobile trailer generator set adopts a leaf spring suspension structure with reasonable node selection, high strength and good rigidity. The power station is easy to move, flexible to operate, and has good sealing and safety. And equipped with hand brake, air brake, rear tail lights and other systems, in line with road driving requirements. Widely used in construction sites, highway, railway construction and temporary locations where electricity is used. So what are the advantages of mobile trailer generator sets? Advantages of mobile trailer generator sets : 1. Active hook traction, 180 ° turntable, flexible steering; 2. The round steel pipe is welded with straight-through axles, and is equipped with a leaf spring suspension structure; 3. The four corners of the frame are provided with mechanical support devices; 4. The vehicle is equipped with steering and tail lights; 5. The size of the car box is determined according to the specifications, and the operator can walk around,...

Diagnosis The Inaccurate Fuel Supply Time of Diesel Generator Sets

After the diesel fuel of the diesel generator set is injected into the cylinder, it is mixed with the air to form a combustible mixture. In order to ensure that the combustible mixture is fully burned, and the combustion pressure reaches a large value at a certain moment after the top dead center, to ensure the diesel generator set diesel engine works normally. When the piston reaches a certain angle before the compression top dead center, the fuel injection pump must supply fuel to the fuel injector. The fuel supply time is expressed by the crankshaft rotation angle, which is called the fuel supply advance angle. The fuel supply advance angle is an important factor that affects the combustion process of the diesel engine. A good fuel supply advance angle makes the power and economy of the   diesel generator set   better. In the process of use, due to the wear of the relevant parts or the change of the relative position, the fuel supply advance angle will change. When it excee...

Do you know how to adjust the oil supply of the Cummins diesel generator set

Do you know how to adjust the oil supply of the Cummins diesel generator set? If the oil supply of each cylinder of the Cummins diesel generator set is uneven (some cylinders are too large, some cylinders are too small), it will directly affect the stability of the engine operation. The fuel injection pump can be removed for inspection and adjustment on the test bench. However, if a test stand is not available, it is necessary to check for uneven oil supply and also to roughly check the oil supply of the suspect cylinder. Check the adjustment method and prepare two glass graduated cylinders for later use. If you can't find the graduated cylinder at this point, you can use two identical vials instead, and in the case of an oversized (or undersized) fuel supply, remove the high-pressure fuel line fitting that connects to the 1-cylinder injector. Remove the high-pressure pipe joint connecting the first cylinder with normal fuel supply and the fuel injector, and insert the two fuel pip...