Advantages of DEUTZ gensets

1. Products have compact structures, reasonable design, excellent and reliable performance, long service life and low usage cost.
2. From the view of product structures, the generators have three product platforms: C, E, D products,with the power range covering 85~340 horsepower.There are more than 300 kinds of products with various forms and adaptability, and these can provide power products with higher technology level and stronger specialization degree for those fields with different demands, such as medium-duty trucks, light vehicles, buses and engineering machiner.
3. Generator products have a series of significant advantages such as advance, efficiency, readability, energy saving and environmental protection.
4. With functions of backflow, well adapt to the plateau and high altitude regions.
5. Starlight series DEUTZ Gensets are the officially authorized products of DEUTZ company. With better performance, better quality and more guaranteed services compared with similar products, they are products recommended by the Diesel Genset Department.

Product overview of DEUTZ gensets

1, DEUTZ engine have advanced technology, reasonable design, excellent and reliable performance and long service life.
2. The emissions of DEUTZ diesel gensets have reached the Europe | | or | | | standard.
3. Equipped with a new type of supercharger, with functions of backflow, well adapt to the plateau and high altitude regions
4. DEUTZ company provides quality assurance for all series of products.
5. DEUTZ company has built a professional service network all over the country, which provides after-sales services and supply spare parts for 24 hours a day.

Instructions for DEUTZ generator set maintenance

1. We should discharge water in oil-water separator and check the level of the start-up battery electrolytic liquid after DEUTZ gensets runs for every 50 hours;
2. We should check the valve clearance and check the fuel injectors after DEUTZs new generators run for 200~300 hours,;
3. We need to check and adjust the transmission belt, replace them when necessary, check and clean the radiator chips and discharge the mud in fuel tank after DEUTZ gensets run for every 50 hours;
4. We need to replace lubricating oil and lubricating oil filter after DEUTZ gensets run for every 600 hours or at least every 12 months; the frequency of replacing the lubricating oil depends on the quality of the lubricating oil, the content fuel sulfur and consumption of lubricating oil by the generating unit.
5. We need to replace the oil-water separator and fuel filter, check whether the supercharger is leak, check whether the air inlet pipeline leaks, check and clean the fuel pipe after DEUTZ gensets run for every 800 hours;
6. Adjust the valve clearance after DEUTZ gensets run for every 1200 hours; replace the air filter and cooling fluid, thoroughly clean the water tank radiator chips and channels after DEUTZ gensets run for every 2000 hours;
7. Check the fuel injector, wash the turbocharger overhaul and overhaul engine equipment after DEUTZ gensets run for every 2400 hours.

Application of DEUTZ gensets

The installed capacity of Deutz engines has achieved rapid development in China. The application scope of DEUTZ engines is broad, including the commercial vehicles, engineering machinery, forklifts, agricultural machinery, compressor and ship, etc.

Installation and chamber design of DEUTZ generators

1. DEUTZ gensets are installed on the concrete floor.
1) We should pour a reinforced concrete base over the floor.
2) The concrete base should pass one month pressure test of over 173 kpa.
3) The concrete base should be at least 150 mm above the floor, with an extension of at least 150 mm per side along the chassis of the set,
4) The cement base should be embedded with the "J" or "L" type anchor bolt.
2. DEUTZ gensets are fixed on the chassis type fuel tank:
1) The shock absorber must be equipped between engine and fuel tank.
2) The structure and strength of the tank must be able to support static load and dynamic load of the sets.
3) We must keep a certain distance between the bottom of the tank and the ground, so as to facilitate the maintenance.

Chamber design of DEUTZ gensets

1) The sets should be in horizontal layout, and they can be in longitudinal layout when they are limited by the building site.
2) When the chamber is adjacent to the control chamber, the outlet end of the generator and the cable trench should be close to the transformer chamber.
3) The battery should be close to the side of the start-up motor
4) The chamber should have enough inlets for fresh air. The duct of the hot air and smoke should be stretched out to the outdoor, air inlet should be placed by the side of the motor, and the air outlet should be installed in the side of the tank.
5) The chamber should adopt comprehensive control measures for the noise removal of sets and sound insulation of chambers.


Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz