Skip to main content

Archive

Show more

Portable power solutions by DEUTZ at MEE 2017





From 14-16 February, DEUTZ will be exhibiting its latest portable power generation solutions at Middle East Electricity 2017 in Dubai

DEUTZ DPSGensetThe DEUTZ Power Solutions genset that will be on stand at MEE 2017. (Image source: DEUTZ)

Under the banner FUTURE DRIVEN engine technology for tomorrow, DEUTZ will be presenting its new DPS (DEUTZ Power Solutions) genset portfolio on a 42 sq m stand in the German Pavilion. These diesel gensets deliver up to 1,000kVA of electrical power for a wide variety of applications.

The highlight at this fair will be the world premiere of the DEUTZ DPS-Hybrid 13 and DPS 20 genset systems, which generate 13kVA and 20kVA respectively. These complete genset systems consist of a diesel engine plus all the other components (generator, control panel, frame) and can be supplied either as free-standing sets or as containerised units.

The DPS-Hybrid 13 also offers an advanced hybrid operating mode, either battery-driven or powered by a solar module. The concept is that if the engine generates more electricity than needed, any excess energy is stored in the battery. If required, this energy can then either boost the engine or even act as the sole power supply source, resulting in fuel savings of up to 65 per cent. If the diesel engine fails, the battery is also able to keep the genset operational for up to 24 hours.

The solar hybrid variant has a solar collector which, in particularly sunny parts of the world, is capable of providing most of the power needed by itself. The diesel engine starts up occasionally, providing additional support at power consumption peaks or on days when the sun does not shine. This allows extremely efficient operation as regards fuel consumption and maintenance plus a long service life. In addition to cost savings, DPS hybrid solutions also represent an environmentally sustainable source of energy.

In Dubai, DEUTZ will also be showing its well-proven DEUTZ BF4M 2011 Telcoengine; with outputs of up to 64 kVA, it is ideal for use in the strongly growing African mobile phone sector. Particular features are its 1,000-hour oil change interval and low fuel consumption.

DEUTZ has its gensets fitted locally by MagiDEUTZ, its Moroccan subsidiary. Africa and the Middle East are among our most important genset markets,explains Georg Diderich, DEUTZ Senior Vice President for Sales & Service in EMEA (Europe, Middle East & Africa).

Being on the spot in Morocco, we can provide our customers with rapid and immediate support for everything from sales and equipment supplies to servicing. Our complete made by DEUTZ gensets are designed precisely to meet market requirements, combining top OEM quality at reasonable overall cost.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...