Marathon MP Series Brushless Three Phase AC Generator




Description of Marathon MP Series Generator

Marathon MP series three phase AC synchronous brushless generator is a new generation brushless generator, which based on MAGNA PLUS generator of Marathon electric co. USA.

MP generator may be combined with diesel engine (internal-combustion engine) to make fixed or movable electrical power. It is suited for commercial buildings, hospitals, factories, farms, fields, etc, as power and lighting. The generating set may be used for the prime power or stand by.

MP series generators are of unique design, advanced construction, excellent performances, reliable operation, easy use, small volume and light weight.

Features:

1. MP series generators are manufactured in accordance with NEM ODP type. It consists of main generator, AC brushless exciter, rotating rectifiers, AVR, conduit box, etc.

2. Class H or Class F insulation system.

3. The frame is made by steel plate. the design of stator lamination is unique. If necessary, 12 lead wires may be supplied.

4. Main rotor apply the single piece 4-pole salient pole lamination, coupled with die cast or welding damping winding, field winding to form a unirotor construction. The field winding is a layer wound with thermo settings epoxy for high mechanical and electrical integrity.

Performance:

1. MP series generator may be operated continually at rated load under following conditions:
a. Ambient: Air temperature 40, well ventilation, marine use, 45
b. Elevation 1000m over sea level

2. Electrical performances

a. Steady voltage regulation 1.0%
b. transient voltage regulations +20%, -15% (60% in, cos= 0.4 lag)
c. Adjustable Voltage range 95-105% Un
d. Waveform distortion at no-load, 5% (line voltage)
e.  Starting motor ability, (no-load, three phase, 4p, cage motor

Principle of Operation:
MagnaPlus generators are a brushless, self excited, extremely voltage regulated, synchronous AC generator. The generator is made of six major components: main stator (armature), main rotor (field), exciter stator (field), exciter rotor (armature), rectifier assembly, and voltage regulator. In understanding the above terminology, note the following: stators are stationary, rotors rotate, a field is an electrical input, and an armature is an electrical output.

The generator's exciter consists of a stationary field and a rotating armature. The stationary field (exciter stator) designed to be the primary source of the generator's residual magnetism. This residual magnetism allows the exciter rotor (armature) to produce AC voltage even when the exxciter and fed directly to the main rotor (field). As the generator shaft continues to rotate, the main rotor (field) induces a voltage produced by the residual magnetism of the exciter allows the automatic voltage regulator to function. The regulator provides voltage to the exciter resulting in a build-up of generator terminal voltage. This system of using residual magnetism eliminates the need for a special field flashing circuit in the regulator. After the generator has established the initial residual voltage, the regulator provides a controlled DC field voltage to the exciter stator resulting in a controlled generator terminal voltage.

Stroage

In the event that the generator is not to be installed on its prime mover immediately, it is recommended that the unit be stored in a cleaned, fry area which is not subject to rapid changes in temperature and humidity.

In the event of long term storage, the generator should be tested cleaned and dried as required, before being put into service. See the maintenance section of this manual for further.

Installation and adjustment

1. Generator must be mounted at the clean, dry and well ventilation place. The prime mover and generator should be installed on a public frame, never put them on the cement floor, and ensure the public frame underformed.

2. Single bearing generators.

Single bearing units are provided a SAE flywheel housing adapter and flexible drive discs to match the engine. Close tolerances are maintained in the manufacture of the generator to promote ease of alignment.

Special stell drive discs are bolted the shaft. In some case spacer are used to achieve the proper :XG" dimension. Holes are provided in the periphery of the coupling discs which correspond to tapped holes in the engine flywheel. The outside diameter of the drive discs fit in a rabbet in the flywheel so that concentricity is assured.

CAUTION: Grade 12.9 place to the flywheel. Do not use split type lock washers, they will cause stress rises, and may result in disc failure.

The SAE flywheel housing adapter and the engine flywheel housing are designed to match each other, with no further alignment necessary.

Shims may be necessary under the generator feet to insure a solid mounting. Do not force the feet to an uneven mounting surface, serious problems could result. ENDPLAY TEST PROCEDURES:

After the generator has been assembled to the engine, check for endplay of the assembled set. Using a suitable lever, force the engine flywheel forward so that the crankshaft is pressed against its thrust bearing. When force is removed, the engine crankshaft should remain in position. Apply force in the opposite direction forcing the crankshaft towards the generator, and observe if the crankshaft remains in the position after force has been removed, refer to the engine manual for proper or recommended endplay. If the crankshaft springs away in either direction after force has been removed. It is an indication that the generator shaft is not moving freely, and normal life of the thrust bearing could be impaired. Probably cause of this problem are:

a. Improper "XG" dimension of either the generator or the engine flywheel, or both. Generator bearing may be bottoming out in its bearing bracket.

b. Misalignment.

a) Improper seating of generator drive discs in the engine flywheel.
b) Improper mating of the generator frame to the engine flywheel housing.
c) Set sub-base is not true. Generator and or engine feet repair shims. See mounting instructions.

3. Two bearing generators.

If generator couples with engine by flange rabbet. It is easy to mount. If it coupled by other way, should pay more attention to installation, it may be necessary to shim the generator feet for proper support and alignment. Aligning the generator and engine as accurately as possible will reduce vibration, increase bearing life, and minimize coupling wear.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...