How To Make Cummins Diesel Generators Service Life Longer




200kw Cummins diesel generator manufacturer solves problem for you.

Because the price of diesel generator usually is high, the use frequency is not good. To reduce production cost, many users are trying to extend the service life of the diesel generator . Any equipment all has a life cycle, which is generally achieved under specific conditions ( under ideal working conditions, strictly in accordance with the requirements of the use instructions for maintenance).

While in practical application, due to changes in environmental conditions and negligence of users, it is impossible to operate machines 100% in accordance with the requirements of operation instructions, especially diesel generators.

So, what we should do to make Cummins generator service life longer? We will give you some suggestions from some problems, as follows:

1.Generator Start-up Preheating Time Problem

Whatever in Summer or Winter, the generator should not run at high speed or with load immediately after starting, especially in winter. After the start-up of the generator set, it should run without load for 3 minutes (summer) to 5 minutes (winter) at idle or low speed (800-1000r/min), and then start working with load. If after starting diesel generator, immediately working under heavy load, at this time temperature of the diesel engine is low, the clearance of friction pairs is relatively small, and the relative lag of lubricating oil at the beginning will cause abnormal wear and tear of these parts. Regular repeated use may lead to abnormal damage of the diesel engine. 



2.Heat insulation problem of intake temperature.
Under normal conditions, the intake temperature of diesel generator should not be higher than 45 ℃. If the intake temperature is too high, we should try to reduce it. In particular, it is necessary to eliminate or reduce the thermal radiation and direct heating effect of exhaust outlet nozzle on intake air. It should be ensured that the distance between intake pipe nozzle and exhaust pipe nozzle is not less than 150 mm, and the interface between exhaust pipe and intake pipe should not leak. Otherwise, should measure to eliminate it. If the generator exhaust pipe nozzle can not be far away from the intake pipe nozzle because of structural constraints, or the exhaust joint leakage can not be eliminated temporarily due to structural restrictions, temporary measures must be taken to separate the two with thin steel plate to minimize the influence of exhaust heat on the intake. When the intake temperature is too high, the air density of the intake cylinder decreases, and the intake volume is relatively insufficient, the diesel generator will emit black smoke when working under heavy load. If the intake temperature is too high, the diesel engine works at high intake temperature for a long time, which may cause serious problems such as piston "top burning" and "cylinder pulling".

3.Cooling problem of diesel generator before shutdown

Diesel generator can not work under whole load after starting up, also can not shut down immediately after work under whole load, especially in summer. The generator set can not be shut down until the temperature of the generator set decreases. If the diesel generator shuts down immediately after full load operation, it is easy to cause "cylinder pulling" and other faults due to the regenerative effect of combustion temperature in the cylinder. Air-cooled generators should pay special attention to cooling before shutdown.


4.Other problems that should be paid attention.

A.In winter, when the generator set starts, should use start-up preheating device according to the requirements. In addition to installing water jacket heater, heating equipment should be installed at the room where conditions permit to ensure high ambient temperature. When starting is difficult, do not use the start-up preheating device for a long time, because when starting the preheating device, the preheating plug installed on the intake pipe will flow out of fuel. The longer the start-up preheating time is, the more fuel the preheating plug will flow out, which will lead to rough start-up or more difficult start-up of diesel engine.

B.For air-cooled diesel generators, after the roof of the air chamber is removed, can not work for a long time under full load operation. If the air chamber of an air-cooled diesel generator does not have a top cover, it is equivalent to that of a water-cooled generator without a radiator. If the diesel generator works at full load for a long time, serious faults will occur.

C.When diesel generator is used in winter, after starting, the idle speed without load or low speed operation time should not exceed 30 minutes. Because of the low ambient temperature in winter, the wear of moving parts such as piston rings will be aggravated when diesel engine runs at low speed and low temperature for a long time.

D.According different seasons to select different viscosity grades of lubricants. If choose If lubricating oil Inappropriately, the generator will be seriously damaged. The General requirements for selecting lubricants are: after confirming the quality grade of lubricants, high temperature lubricants (such as 40, 50, 60, etc.) are used in high temperature areas in summer and low temperature lubricants (such as 0W, 5W, 10W, etc.) are used in cold areas in winter. Mixed lubricants (15W/40, 20W/40, etc.) can be used in other areas.

E.Regularly check the fastening condition of the support, shock absorber rubber block and bolts in each fastening part of the whole set of Volvo diesel generator set. If the diesel generator support shock absorber rubber is damaged quickly, the support bolt is loosened or the main fastening part of the bolt is loosened, the vibration of the diesel generator will be increased, and long-term operation may lead to serious damage to the diesel engine.
F.Regularly clean dust deposits on the heat dissipation surfaces of Volvo generators, check the status of heat dissipation system and fan system, so that the cooling system of diesel generators is always in good working condition, which is also one of the effective ways to extend the service life of Cummins diesel generators.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...