Skip to main content

Archive

Show more

Ignition Delay Period of Mixture for 50kw Deutz Diesel Generator



The period from the injection of diesel oil into the cylinder to the beginning of the ignition is called the ignition delay period.

Today 50kw Deutz diesel generators manufacturer shares ignition delay period of mixture with you.

During the ignition delay period, the mixture in the combustion chamber undergoes physical and chemical preparation.

Physical preparation process: crushing, dispersing, evaporating, vaporizing and mixing of fuel;

Chemical preparation process: the initial chemical reaction of the mixture until spontaneous combustion begins

Characteristics: pressure does not deviate from the compression line.
The length of ignition delay period of diesel engine will affect the amount of fuel injection and prefabricated mixture in this stage, thus affecting the combustion characteristics, power, economy, emission characteristics and noise and vibration of diesel engine. We should control it.

Main factors affecting ignition delay:
The higher the temperature and pressure in the cylinder, the shorter the ignition delay.
Diesel oil has better spontaneous combustion (higher cetane number) and shorter ignition delay.

The shape and wall temperature of combustion chamber.
Injection advance angle: from the beginning of injection to the piston reaching the top dead center, the corresponding crankshaft rotation angle is the injection advance angle.

Cetane number: it is the index of spontaneous combustion of diesel oil when it is burned in a diesel engine. The spontaneous combustion of pure hexadecane is good, and the cetane number is set at 100.

Pure alpha-methylnaphthalene is not easy to burn, and its cetane number is set to zero. When mixed in different proportions, standard fuels with different explosion resistance grades of cetane number 0 to 100 can be obtained, and compared with diesel oil to be tested on a single cylinder test machine with certain structure.

The ignition retardation period is from pressure point to temperature point. At the beginning of the retardation period, although combustion products have been formed in the cylinder, a large amount of mixture is still burning.

Flame retardation characteristics:
The fuel injection process ended basically, and the combustion rate decreased (the concentration of oxygen and diesel oil decreased, and the exhaust gas increased).
Pressure start to reduce( Cylinder Volume Increasing). The temperature reaches a high point. Generally, the temperature can reach about 2000K, which usually appears at the 200 crankshaft corner after the top dead-end point.


Reimbursement period
From the high point of temperature until the fuel is almost burnt out, it called reimbursement period. It is difficult to accurately determine the end point of the reimbursement period. Generally, the end of the reimbursement period can be considered when the heat release reaches 95% to 99% of the total heat release in the cycle.

The combustion of internal combustion oil during the supplementary combustion period can be called afterburning. Due to the burning time is short, mixture is not very uniform, there is always a small amount of fuel delayed to continue burning during expansion. Especially in high-speed and high-load conditions, because of the small excess air coefficient, the time of mixture formation and combustion is shorter, and this phenomenon of afterburning is more serious.
During the reimbursement period, because the piston goes down a considerable distance, the volume of the cylinder increases a lot, and the pressure and temperature in the cylinder decrease rapidly, the combustion speed is very slow, the heat emitted is difficult to use effectively, and the exhaust temperature rises, resulting in an increase in heat loss, which is not conducive to the economy of the diesel engine.

In addition, the afterburning also increases the heat load of the parts concerned. Therefore, the supplementary combustion period should be shortened as far as possible to reduce the amount of fuel burned in the supplementary combustion period.

Above is the ignition delay period of mixture for 50kw Deutz diesel generator.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz