Water cooling method for 1300kw Cummins Generators


When we use 1300kw Cummins diesel generator, we need to do some work to cool down it and generator room. There are water cooling and air cooling methods. Today Starlight power factory mainly talks about water cooling station.


When the water source is sufficient and the water temperature is low, the cooling mode of the power station should be water-cooled, that means using water as refrigerant to cool the air in the generator room of diesel generating sets. The conditions for designing water-cooled power stations are that there should be sufficient natural water sources, such as well water, spring water, River water, lake water or other available water sources, good water quality, non-toxic, tasteless, non-pathogenic bacteria, non-corrosive to metals, and the contents of inorganic and organic substances such as sediment in water should meet the standards.


If water-cooled, the temperature should be low. The difference between the room temperature of diesel generator set and that of water-cooled water should be greater than 15 degrees Celsius, and generally not less than 10 degrees Celsius. If the water temperature is high, the temperature difference between the return air and the supply air is small and the air supply system is large, so the construction investment and operation cost must be increased.

Compared with other cooling modes, the advantages of water-cooled power station are that the air intake and exhaust volume are smaller, so the air intake and exhaust pipes are smaller. Water-cooled power station is less affected by the external atmospheric temperature of the project, and can ensure the air cooling of the generator room in any season. The disadvantage is that the water consumption is large and limited by the water source conditions. When there is no sufficient low-temperature water source in the project, the cooling method can not be adopted.

The cooling mode of water-cooled power station can adopt the sprinkler cooling mode, also called water-washed air. Because the hot air in the machine room is directly in contact with the water droplets, the cooling and heat exchange effect is better. At the same time, the harmful dust in the machine room can be washed by the water to make it clean.

Surface cooling can also be used in water-cooled power plants, that means the hot air in the generator room exchanges heat with the cooling water on the surface of the metal cooler. The advantage of this cooling method is flexible cooling system, which can be configured according to the need, and does not occupy or occupy less the area of diesel generator room. For example, some diesel generating units with closed cycle cooling are equipped with head radiators, which can not be used in the closed power plant room. The cooling water of diesel engine can be changed into an open system, and cooling water is introduced into the head radiator to reduce the temperature of the engine room and eliminate the waste heat of the power plant.

Starlight manufacturer was set up in 1974. We focus on high quality diesel generator set. Brands cover Cummins, Volvo, Perkins, Deutz, Mtu, Yuchai, Shangchai, Wechai, Wuxi power, Ricardo etc. If you are interested, please contact sherly@dieselgeneratortech.com.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz