The Ways to Prevent Sand from 600kw Diesel Generator Set in Desert Area

The desert area is short of water all the year round, the temperature in summer is super high, and the temperature difference between day and night is big, but these are not enough to defeat 600kw diesel generator set. However, there is a large amount of sandstorm in the desert area. If the sand control measures are not taken properly, it is likely to affect the working efficiency of the unit. Even cause unit wear, reduce unit life. Therefore, it is necessary to take sand control measures and pay special attention.

How to control sand for 600kw diesel generator set in desert area?
The sand control measures are mainly aimed at the air inlet end of the unit, that is, the air intake valve. There is an air filter element at the air inlet end of the unit, but this can only be satisfied with the general environment. In order to avoid the large amount of dust into the engine body, causing early wear of diesel generator set. We can cover the cap of the air filter element with a fine hole gauze to prevent sand.

diesel generator set

What should we pay attention to the use of 600kw diesel generator set in desert area?
When operating the unit.
1.After starting the diesel engine, it should idle for 3-5 minutes, and then rise to the rated speed, do not suddenly make it run at high speed.
2.When the diesel generator set is in working condition (with high temperature), it is forbidden to open the water tank cover to avoid scalding.
3.To prevent the components from getting involved in the machine. It is forbidden to start the generator set after the protective net of the generator set is removed.
4.Observe the water temperature and oil pressure at any time during the operation of the unit. Stop the unit if the water temperature is higher than 100 ℃ or the oil pressure is lower than 0.1.
When stopping the unit.
1.Slow down the speed and stop the unit after idling for 3-5 minutes.
2.When the ambient temperature is lower than 0 ℃, drain the water in the water tank, diesel engine body and oil cooler.
Special attention.
1.The generator air switch (circuit breaker) must be disconnected before starting and stopping. It is strictly prohibited to start or stop the unit when it is loaded.
2.It is forbidden to operate the diesel engine for too long time(no more than 15 minutes) without load.

Some users think that although in desert area, but the generator set is used in the machine room and will not be affected by the wind and sand, so they do not protect the unit against sand. In fact, this is a unilateral idea. Even indoors, the amount of windblown sand in the air in desert areas is much higher than that in general areas. The air filter element of the unit can not completely isolate these sandstorms, so in order to protect your unit, you must carefully implement the above sand prevention measures.
Our diesel generator sets are sold to all over the world, also many clients buy unit for desert areas. Therefore, we recommend more suitable units to customers according to the site where they use diesel generators.

How to configure parts of diesel engine and alternator in desert areas?
1.Heavy duty air filter. To prevent excessive dust in the air from affecting the engine.
2.Alternator filter net. Prevent the dust in the air from entering the electric ball, which will reduce the power by 5%.
3.Diesel filter and primary filter. To prevent dust in the air from entering the fuel system.
The above optional products can effectively prevent dust damage to the alternator or engine.

Diesel generator set for desert is one of many special condition generator sets. In addition, we should pay attention to the selection and matching of diesel generator set under high temperature and high altitude conditions. For these conditions, we also can provide effective solutions.

Starlight Power is a manufacturer of diesel generators with more than 43 years’ experience. If you plan to purchase generator set for desert areas or others, but do not know how to do, welcome to contact us(sales@dieselgeneratortech.com). Professionals will answer for you.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...