Skip to main content

Archive

Show more

The Ways to Prevent Sand from 600kw Diesel Generator Set in Desert Area

The desert area is short of water all the year round, the temperature in summer is super high, and the temperature difference between day and night is big, but these are not enough to defeat 600kw diesel generator set. However, there is a large amount of sandstorm in the desert area. If the sand control measures are not taken properly, it is likely to affect the working efficiency of the unit. Even cause unit wear, reduce unit life. Therefore, it is necessary to take sand control measures and pay special attention.

How to control sand for 600kw diesel generator set in desert area?
The sand control measures are mainly aimed at the air inlet end of the unit, that is, the air intake valve. There is an air filter element at the air inlet end of the unit, but this can only be satisfied with the general environment. In order to avoid the large amount of dust into the engine body, causing early wear of diesel generator set. We can cover the cap of the air filter element with a fine hole gauze to prevent sand.

diesel generator set

What should we pay attention to the use of 600kw diesel generator set in desert area?
When operating the unit.
1.After starting the diesel engine, it should idle for 3-5 minutes, and then rise to the rated speed, do not suddenly make it run at high speed.
2.When the diesel generator set is in working condition (with high temperature), it is forbidden to open the water tank cover to avoid scalding.
3.To prevent the components from getting involved in the machine. It is forbidden to start the generator set after the protective net of the generator set is removed.
4.Observe the water temperature and oil pressure at any time during the operation of the unit. Stop the unit if the water temperature is higher than 100 ℃ or the oil pressure is lower than 0.1.
When stopping the unit.
1.Slow down the speed and stop the unit after idling for 3-5 minutes.
2.When the ambient temperature is lower than 0 ℃, drain the water in the water tank, diesel engine body and oil cooler.
Special attention.
1.The generator air switch (circuit breaker) must be disconnected before starting and stopping. It is strictly prohibited to start or stop the unit when it is loaded.
2.It is forbidden to operate the diesel engine for too long time(no more than 15 minutes) without load.

Some users think that although in desert area, but the generator set is used in the machine room and will not be affected by the wind and sand, so they do not protect the unit against sand. In fact, this is a unilateral idea. Even indoors, the amount of windblown sand in the air in desert areas is much higher than that in general areas. The air filter element of the unit can not completely isolate these sandstorms, so in order to protect your unit, you must carefully implement the above sand prevention measures.
Our diesel generator sets are sold to all over the world, also many clients buy unit for desert areas. Therefore, we recommend more suitable units to customers according to the site where they use diesel generators.

How to configure parts of diesel engine and alternator in desert areas?
1.Heavy duty air filter. To prevent excessive dust in the air from affecting the engine.
2.Alternator filter net. Prevent the dust in the air from entering the electric ball, which will reduce the power by 5%.
3.Diesel filter and primary filter. To prevent dust in the air from entering the fuel system.
The above optional products can effectively prevent dust damage to the alternator or engine.

Diesel generator set for desert is one of many special condition generator sets. In addition, we should pay attention to the selection and matching of diesel generator set under high temperature and high altitude conditions. For these conditions, we also can provide effective solutions.

Starlight Power is a manufacturer of diesel generators with more than 43 years’ experience. If you plan to purchase generator set for desert areas or others, but do not know how to do, welcome to contact us(sales@dieselgeneratortech.com). Professionals will answer for you.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz