Why is Voltage Transformer of Generator Set Failure?

Some users may not know about voltage transformer of Perkins generator set. Voltage transformer is a special transformer with limited structure and use form. 

What causes voltage transformer failure in Perkins diesel generator set?
1.Winding turn to turn short circuit
Fault phenomenon: During operation, the temperature rises, there is discharge sound, the high-voltage fuse is blown, the secondary side voltmeter indication is unstable.
Reason: System over-voltage, long-term overload operation, aging insulation, poor manufacturing process.

2.Insulation damage between iron chips
Fault phenomenon: temperature rise during operation.
Reason: Poor insulation between iron chips; Poor service environment; Long term operation at high temperature promotes aging of insulation between iron chips.
3.Poor contact between grounding lug and iron core of diesel engine
Fault phenomenon: There is discharge sound between iron core and oil tank during operation.
Reason: The grounding plate is not inserted tightly, and the mounting screw is not tightened.
4.Core loosening
Fault phenomenon: There is abnormal vibration or noise during operation
Reason: The iron core clamp is not clamped, and the iron chip is loose.

Perkins generator set
5.Winding break.
Fault phenomenon: During operation, there may be arc and discharge noise at the disconnection. The voltmeter indication of the broken phase is reduced or zero.
Reason:The winding leads are broken due to poor welding process, insufficient mechanical strength or unqualified outgoing wires.
6.Winding to ground insulation breakdown.
Fault phenomenon: The fuse on the high voltage side of the diesel engine is continuously blown, which may cause discharge noise.
Reason: The winding insulation is aging or there are conductive sundries in the winding, the insulating oil is damped, over-voltage breakdown, serious oil shortage, etc.
7.Short circuit between winding.
Fault phenomenon: The fuse on the high-voltage side is blown, the oil temperature is increased sharply, and even the fuel injection is smoking.
Reason: he winding insulation is aging, the insulating oil is damped, and there is serious oil shortage.
8.Discharge flashover between casings.
Fuse on high voltage side is fused and bushing flashover is discharged.
Reason: Mechanical damage of casing due to external force. There are foreign matters or small animals entering between casings, the casings are seriously polluted and the insulation is poor.

When using voltage transfer, what should we pay attention to?
1.We should operate with a suitable transformation ratio, rated capacity, accuracy level. And consider that the voltage drop caused by the secondary wiring will affect the measurement results, so the length can not be too long.

2.The primary winding of the voltage transformer is connected to the line, and the secondary winding is connected to the measuring instrument and relay. When wiring, pay attention to polarity group and phase, and do not connect them wrong.

3.The primary and secondary sides of the voltage transformer shall be equipped with fuses to prevent short circuit accidents. When working on the secondary circuit, pay attention not to short circuit the secondary side of the voltage transformer, otherwise it will cause overheating and burn the transformer.
4.One end of secondary side of voltage transformer shall be grounded for the same reason as current transformer.

When voltage transformer of Perkins generator set failure, we must find out the reasons and remove the problem. 

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz