Skip to main content

Archive

Show more

250kw/312.5kva diesel generators powered by Cummins engine NTA855-G1

250kw diesel generator set is assembled by Jiangsu Starlight Electricity Equipments Co.,Ltd. in China, our factory was founded in 1974, as one of the biggest supplier, we have focused on high quality generators for more than 43 years.

1.General Features of the 250kw diesel genset
All qualified generator sets are subjected to a comprehensive performance test which includes 50% load, 75% load, 100% load, 110% load and to check, verify that all control systems, alarm and shut-down protection.
Equipped with battery charger and 24V high performance maintenance-free lead-acid starting batteries and connecting cables.
Stainless galvanized zinc plates with strong corrosion-proof.
Vibration isolators between the engine/alternator and base frame.
Equipped with industrial silencer and flexible exhaust hose.
Designed to comply with ISO8528/GB2820.
Powered by Cummins engine NTA855-G1 and Stamford alternator HCI444C1
Water jacket preheater, oil heater and double air cleaner, etc. are available.
2. Technical data of 250kw Cummins diesel generator set
Prime power/capacity: 250kw/312.5kva
Engine make: Cummins
Standby power/capacity: 275kw/344kva
Engine model: NTA855-G1
Alternator made: Stamford Control panel: SmartGen HGM6110
Alternator model: HCI444C1 Speed/frequency: 1800rpm/60Hz
Voltage: 220~480V Noise level
open type: 100dBA at 7 meters
soundproof type: 75dBA at 7 meters
Start up time: 5~6s
Voltage Regulation: ≥±5%
Sudden Voltage Warp (100% Sudden Reduce): ≤+25%
Sudden Voltage Warp (Sudden Increase): ≤-20%
Voltage Stable Time (100% Sudden Reduce): ≤6s
Voltage Stable Time (Sudden Increase): ≤6s
Frequency Recovery Time(100%Sudden Reduce): ≤6s
Frequency Regulation: ≤5%
Voltage Stable Time (100% Sudden Reduce): ≤5s
3.Cummins Technical Specifications
Prime power/capacity: 287kw/358.75kva
Engine Model: NTA855-G1
Standby power/capacity:317kw/396.25kva
Manufacturer: Cummins( CCEC China)
Speed: 1800rpm
Cylinder Arrangement: In-line
Cylinder quantity: 6
Cycle: 4
Aspiration: Turbocharged and After-cooled
Displacement: 14L
Bore x Stroke : 140×152mm
Compression Ratio: 14.5:1
Type Injection System: Direct injection Cummins PT
Friction Energy Output: 44kw
Piston Speed: 9.1 m/s
Total Lubrication System Capacity: 38.6L
Coolant Capacity: 49.2L
Starter motor: DC24V
Fuel Consumption at 100% load: 74 L/h
75% load: 56L/h,
50% load: 40L/h
4.Alternator technical specifications
Alternator model:HCI444C1
Exciter type Single bearing, Brushless,Self-excited
Alternator manufacturerSTAMFORD
Rated output prime power312.5KVA
Rated speed1800 rpm
Number of phase3
Rated frequency60Hz
Rated voltage (Available with custom requirements)230/400V
Power factor0.8lag
Insulation gradeH
Voltage regulation NL-FL ≤±1%
Protection gradeIP23
(PS: alternator options: Leroy Somer, Engga, Marathon, Siemens, Shanghai Kepu, as well as our own brand Starlight)
5.Control panel technical specification
SmartGen HGM6110 automatic controller, integrating digital, intelligent and network techniques, is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and three ―remote‖ (remote control, remote measure and remote communication). The controller uses LCD display, optional display interface including Chinese, English, Spanish, Russian,Portuguese, Turkish, Polish and French with easy and reliable operation.
Jiangsu Starlight series Cummins generators power range is 20kw-2000kw, if you have purchase plan, welcome to contact us by email sales@dieselgeneratortech.com, or call us by phone +8613481024441. We will work with you.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...