The diesel generator and voltage regulator have been had matching test at the factory. Therefore, when loading and using, the 200kw Cummins genset and voltage regulator shall be installed and used together with the same number and the same ex factory date. 

Only acceptance test shall be carried out by the user. If the generator and voltage regulator are overhauled, the components affecting the electromagnetic performance have changed, or the number of the generator and voltage regulator are different, the matching test must be carried out. The test steps are as follows:

1.Appearance inspection: the generator and voltage regulator shall be intact, all screws shall be free of looseness, and the rotor shall rotate flexibly without friction, otherwise, they shall be disassembled for inspection.

2.Connect the steam pipe, connect the high-pressure steam, no-load for several minutes, and measure the speed within the rated range. Measure the voltage between the two terminals (two thick wires) of the generator, which should be above I V, and below 1 V, which should be magnetized.

3.Connect the wiring of each part. It is recommended to connect the AC ammeter in series at the load end and the AC voltmeter on the terminal board and terminal of the voltage regulator.

Diesel generator set is generally composed of diesel engine, AC synchronous generator and control panel (power distribution and control system).
The diesel engine and the three-phase AC synchronous generator are generally rigidly connected and directly installed on the trailer frame or fixed bracket through the shock absorber. The control panel, diesel box and battery box of the mobile diesel generator set are directly installed on the frame; the common base of the fixed diesel generator set is generally fixed on the specially designed reinforced concrete foundation, and the battery is placed on the starter side of the diesel engine.

Some of the control panels of the fixed unit are installed on the upper part of the alternator through the triangular iron bracket, and the smaller control panel is installed on the upper part of the control component shell of the alternator.

Starlight Power diesel generator power range is from 20kw to 3000kw, if you are interested, please contact us by sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz