Harms caused by small faults and untimely maintenance of diesel generator sets



As we all know, the service life of diesel generator set is closely related to correct operation and reasonable use. When the unit breaks down, it needs to be repaired in time, but some users think that some minor faults do not affect the use of the unit, so they ignore them, and they will not repair until the unit "strikes", which is extremely incorrect. Today, I'll talk about the harm of diesel generator set's small failure and untimely maintenance.


1.If the maintenance of small faults of diesel generators is not timely, there will be short-circuit between turns of stator winding, which will generate ring current under the action of short-circuit voltage, which may cause turn to turn short circuit to develop into single-phase ground short circuit and phase to phase short circuit. When the multi-phase phase to phase short circuit occurs in the stator winding, it is the most harmful to the unit, and the short circuit current will cause the unit to burn down.

2.If the generator set is not maintained in time, the excitation current will drop sharply or disappear. The unit will absorb a lot of reactive power from the system, and the unit will change from synchronous operation to asynchronous operation. The system voltage will also drop, which will cause the system to collapse in serious cases.
3.If there is a small fault that is not repaired in time, the excitation circuit will be grounded. The excitation circuit of the unit is grounded in one point and two points respectively. Generally speaking, when the excitation circuit is grounded at one point, there is no serious harm to the unit. However, if the maintenance is not carried out in time, two-point grounding may occur, which will destroy the balance of the rotor flux, cause strong vibration of the generator, and finally burn the rotor winding.
4.If the diesel generator set is not maintained in time, the unit will over-voltage. When the unit is in operation and load rejection occurs suddenly, over-voltage may occur due to the large inertia of the speed control system, resulting in the breakdown of the insulation layer of the unit.
5.If the unit fails to be repaired in time, the unit will be overloaded. Generator overload refers to the operation of the unit beyond the rated capacity. If it is a short-term overload operation, it will generally cause the stator winding temperature rise and accelerate the aging of the insulation part, affecting the normal service life of the unit. If it is overloaded for a long time, it is possible to burn down the stator winding, and the final result is that the unit cannot generate electricity.
6.If the small fault of the unit is not repaired in time, the stator will be over-current. Stator overcurrent is generally caused by external short circuit or system oscillation. When it is slight, the stator temperature will rise to accelerate the aging of the insulation part of the winding; when it is serious, other major faults will occur.

In order to prevent large failures of the unit, the user should stop the unit immediately after finding small failures, check and eliminate the failures, and put the unit into use after repair. In addition, the corresponding protection device can be set on the diesel generator set to play a better role in protecting the diesel generators.


Starlight Power is diesel generator manufacturer in China, founded in 1974. We have focused on high quality product for more than 43 years, covering Cummins, Volvo, Perkins, Yuchai, Shangchai, Deutz, Ricardo, Weichai, Wuxi etc. Power range is from 25kva-3125kva, welcome to contact us for inquiry.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Silent Cummins 640kw Diesel Generating Sets

Technical data of 800KVA AC diesel generator set The DG Set is skid mounted, directly coupled with Cummins water cooled engine with built in shock absorber for anti vibration. The alternator is Stamford brand with brushless and self excited, with control panel and protection system complete set. Prime power: 640KW/800KVA Standby power:704KW/880KVA Rated voltage: 230/400V Rated current: 1152A Speed/frequency:1500rpm/50Hz ( or 1800rpm/60Hz) Power factory:0.8lag Size: open type genset: 4.2 x1.82x2.25m, silent genset: 6.5 x2.6 x2.78m Net wight: open type genset: 7800kg,   silent genset : 12000kg Technical Data of Diesel Engine Diesel engine brand/model: Chongqing Cummins/ KTA38-G2B( full new) Prime/standby power: 790KW/920KW 4 Stroke Cycle , 60° Vee , 12 Cylinder, Turbocharged &Aftercooled, 1500rpm, 50Hz, bore/stroke: 159/159mm. The Cummins diesel engine is equipped with electronic type governor, over speed shutdown devices to protect against runaway when electronic governor or con...

Guides to Clean VOLVO Diesel Generator Cooling System

VOLVO Engine Cooling System Volvo engine's internal cooling system makes sure the engine works at the right temperature. It is a closed system that must always be filled with a mixture of concentrated coolant and water in order to protect the engine against internal corrosion, cavitation and bursting due to freezing. Coolant of a suitable chemical composition must be used all year round. This also applies in areas where there is never any risk of freezing, to provide the engine of  diesel generator set   with full corrosion protection. The use of anti-corrosion agents alone is not permitted in Volvo Penta engines. Never use water alone as a substitute for coolant. The corrosion protection additives become less effective over time, which means that the coolant must be changed at regular intervals; refer to Maintenance Schedule. The cooling system must be flushed whenever the coolant is changed; Volvo Penta coolants have been prepared to work best ...