Harms caused by small faults and untimely maintenance of diesel generator sets



As we all know, the service life of diesel generator set is closely related to correct operation and reasonable use. When the unit breaks down, it needs to be repaired in time, but some users think that some minor faults do not affect the use of the unit, so they ignore them, and they will not repair until the unit "strikes", which is extremely incorrect. Today, I'll talk about the harm of diesel generator set's small failure and untimely maintenance.


1.If the maintenance of small faults of diesel generators is not timely, there will be short-circuit between turns of stator winding, which will generate ring current under the action of short-circuit voltage, which may cause turn to turn short circuit to develop into single-phase ground short circuit and phase to phase short circuit. When the multi-phase phase to phase short circuit occurs in the stator winding, it is the most harmful to the unit, and the short circuit current will cause the unit to burn down.

2.If the generator set is not maintained in time, the excitation current will drop sharply or disappear. The unit will absorb a lot of reactive power from the system, and the unit will change from synchronous operation to asynchronous operation. The system voltage will also drop, which will cause the system to collapse in serious cases.
3.If there is a small fault that is not repaired in time, the excitation circuit will be grounded. The excitation circuit of the unit is grounded in one point and two points respectively. Generally speaking, when the excitation circuit is grounded at one point, there is no serious harm to the unit. However, if the maintenance is not carried out in time, two-point grounding may occur, which will destroy the balance of the rotor flux, cause strong vibration of the generator, and finally burn the rotor winding.
4.If the diesel generator set is not maintained in time, the unit will over-voltage. When the unit is in operation and load rejection occurs suddenly, over-voltage may occur due to the large inertia of the speed control system, resulting in the breakdown of the insulation layer of the unit.
5.If the unit fails to be repaired in time, the unit will be overloaded. Generator overload refers to the operation of the unit beyond the rated capacity. If it is a short-term overload operation, it will generally cause the stator winding temperature rise and accelerate the aging of the insulation part, affecting the normal service life of the unit. If it is overloaded for a long time, it is possible to burn down the stator winding, and the final result is that the unit cannot generate electricity.
6.If the small fault of the unit is not repaired in time, the stator will be over-current. Stator overcurrent is generally caused by external short circuit or system oscillation. When it is slight, the stator temperature will rise to accelerate the aging of the insulation part of the winding; when it is serious, other major faults will occur.

In order to prevent large failures of the unit, the user should stop the unit immediately after finding small failures, check and eliminate the failures, and put the unit into use after repair. In addition, the corresponding protection device can be set on the diesel generator set to play a better role in protecting the diesel generators.


Starlight Power is diesel generator manufacturer in China, founded in 1974. We have focused on high quality product for more than 43 years, covering Cummins, Volvo, Perkins, Yuchai, Shangchai, Deutz, Ricardo, Weichai, Wuxi etc. Power range is from 25kva-3125kva, welcome to contact us for inquiry.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...