Specifications of 200KW Perkins engine Genset-Starlight Power

200KW/250KVA prime Perkins diesel generator is supplied by Starlight Power manufacturer.
Generator set information:
Genset model: XG-200GF
Prime power: 200KW/250KVA
Standby power: 220KW/275KVA
Rated speed: 1500rpm
Rated frequency: 50Hz
Rated voltage:230/400V
Power factor: 08.lag
Electric phase: 3 phases & 4 wires
Diesel engine information:
Perkins engine: 1506A-E88TAG3
Number of cylinders: 6 vertical in-line
Bore and stroke: 112 x 149 mm
Displacement:8.8L
Aspiration: Turbocharged aftercooled
Cycle: 4 stroke
Combustion system: Direct injection
Compression ratio: 16.1:1
Total lubricating capacity: 41L
Cooling way: water-cooled
Features and benefits
1.Dependable power
2.The 1506A-E88TAG3 delivers greater productivity through an improved power to weight ratio
3.The world-class power density has been achieved from an 8.8 litre turbocharged engine using a hydraulic actuated
unit injection (HEUI) fuel system; making this engine robust for all markets due to its ability to cope with the variation
of fuel quality around the world
4. In its class, the 1506A-E88TAG3 has been designed to provide dependable power even in extreme ambient
climates
Low operating costs
1.Oil change service intervals are set at 500 hours as standard
2.Designed to provide low cost of ownerhsip, simple maintenance and reduced downtime
3.12 months unlimited warranty with 24 months on Major items. For low use applications <500 hours per year
warranty is extended by a further 12 months. See Perkins Warranty Policy for further details
4.Extended service contracts – protect and plan the cost of ownership.
5.The 1506-E88TAG3 has been designed to hit the power node requirements of our customers.
6.Switchability functionality from 50Hz/1500rpm to 60Hz/1800 rpm and vice versa is available to provide greater flexibility for frequency selection
World class product support
Our experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their disposal, covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine.
Perkins actively pursues product support excellence by insisting our distribution network invest in their territory to provide customers with a consistent quality of support across the globe
Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts giving 100% reassurance that you receive the very best in terms of quality for lowest possible cost, wherever your Perkins powered machine is operating in the world.
More specifications and price of 200KW/250KVA Perkins generator, welcome to contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...