Skip to main content

Archive

Show more

Specifications of 200KW Perkins engine Genset-Starlight Power

200KW/250KVA prime Perkins diesel generator is supplied by Starlight Power manufacturer.
Generator set information:
Genset model: XG-200GF
Prime power: 200KW/250KVA
Standby power: 220KW/275KVA
Rated speed: 1500rpm
Rated frequency: 50Hz
Rated voltage:230/400V
Power factor: 08.lag
Electric phase: 3 phases & 4 wires
Diesel engine information:
Perkins engine: 1506A-E88TAG3
Number of cylinders: 6 vertical in-line
Bore and stroke: 112 x 149 mm
Displacement:8.8L
Aspiration: Turbocharged aftercooled
Cycle: 4 stroke
Combustion system: Direct injection
Compression ratio: 16.1:1
Total lubricating capacity: 41L
Cooling way: water-cooled
Features and benefits
1.Dependable power
2.The 1506A-E88TAG3 delivers greater productivity through an improved power to weight ratio
3.The world-class power density has been achieved from an 8.8 litre turbocharged engine using a hydraulic actuated
unit injection (HEUI) fuel system; making this engine robust for all markets due to its ability to cope with the variation
of fuel quality around the world
4. In its class, the 1506A-E88TAG3 has been designed to provide dependable power even in extreme ambient
climates
Low operating costs
1.Oil change service intervals are set at 500 hours as standard
2.Designed to provide low cost of ownerhsip, simple maintenance and reduced downtime
3.12 months unlimited warranty with 24 months on Major items. For low use applications <500 hours per year
warranty is extended by a further 12 months. See Perkins Warranty Policy for further details
4.Extended service contracts – protect and plan the cost of ownership.
5.The 1506-E88TAG3 has been designed to hit the power node requirements of our customers.
6.Switchability functionality from 50Hz/1500rpm to 60Hz/1800 rpm and vice versa is available to provide greater flexibility for frequency selection
World class product support
Our experienced global network of distributors and dealers, fully trained engine experts deliver total service support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their disposal, covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine.
Perkins actively pursues product support excellence by insisting our distribution network invest in their territory to provide customers with a consistent quality of support across the globe
Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts giving 100% reassurance that you receive the very best in terms of quality for lowest possible cost, wherever your Perkins powered machine is operating in the world.
More specifications and price of 200KW/250KVA Perkins generator, welcome to contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz