Skip to main content

Archive

Show more

The parallel cabinet for 250KW generator set

The parallel cabinet for 250KW generator set is basically equipped with electronic speed regulation module, synchronous module, load distribution module, interface card and other control modules, circuit breaker, display instrument and other configurations.
 
The parallel cabinet is generally the size of international electrical standard cabinet, and can also be processed according to the size required by users.
 
All indicating instruments on the cabinet, all control relays, change-over switches and potentiometers of the parallel generator set are imported or domestic high-quality products, and the protection level of the cabinet conforms to IP22 standard.
 
Parameter display: current, voltage, frequency, power, power factor meter
 
Today Starlight Power tell you how to install parallel cabinet for 250kw generator set.
 
1.Install the diesel generator set and parallel cabinet in place.
2.Connect the primary output cable of the diesel generator set with the corresponding parallel cabinet one by one according to the correct phase sequence (the output terminal of the generator and the incoming terminal of the parallel cabinet are marked with corresponding phase sequence) and tighten it according to the regulations.
3.Connect the load directly to the bus bar of the parallel cabinet, such as the outgoing cabinet when ordering. It is connected to the outgoing cabinet of corresponding capacity, and the user does not need to add the combiner cabinet and busbar.
 
Hope above information is helpful to you. Starlight Power not only supply technical support, but also supply diesel generator set, if you have purchase plan, welcome to contact us by sales@dieselgeneratortech.com or call us +8613481024441.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz