Skip to main content

Archive

Show more

High quality 220kw Cummins diesel generator set

220KW Cummins silent diesel genset is produced by Jiangsu Starlight factory. It it soundproof, rainproof type, equipped with Cummins diesel engine NT855-GA, alternator Stamford HCI444D1 and control panel SmartGen 6110.

 

1. Description/technical specification

Genset model: XG-220GF

Genset Output: 275KVA/220KW

Voltage output: 400/230VAC ( can also made as you need)

Frequency: 60Hz

Power factor: 0.8 lagging

Operating mode:Standby power

Mounting: Skid base with anti-vibrating mountings

Country of origin: China

Certificate: ISO, CE

Fuel tank: The set comes with high capacity base integral fuel tank complete with a fuel gauge

The period of validity of the warranty for 220KW Cummins silent genset is 12 months or 1000 run hours whichever comes first after delivery, installed and accepted and commissioned at the final destination.

Supply together with detailed user manual, engine parts catalog, maintenance & repair manual etc.


 Starlight diesel genset


2. General diesel engine data

Engine model: CCEC Cummins NT855-GA

Engine output power: standby power 257kw

Aspiration: Turbocharged

Cylinders: 6

Speed: 1800 r/min

Displacement: 14L

Bore x stroke: 140x152mm

Fuel System: Cummins PT

Fuel consumption: 100%: 59.4L/h, 75%: 45.5L/h, 50%: 32.3L/h

Standard: ISO3046

All data is based on :

Engine Operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer, fan, and optional driven components.

 

EXHAUST SYSTEM

Maximum Allowable Back Pressure: 3.0in.Hg (10kPa)

Standard Exhaust Pipe Diameter: 5.0 in. (127mm)

AIR INDUCTION SYSTEM

Maximum Allowable Intake Air Restriction

With Clean Filter Element: 15 in. H2O (3.74kPa)

With Dirty Filter Element: 25in. H2O (6.22kPa)  

Minimum Dirt Holding Capacity: 25 g/CFM ( 53g/L/s )

Maximum Allowable Intake Air Temperature ∆T: 30°F (17°C)

 

COOLING SYSTEM

Coolant capacity - engine only 5.5 U.S. gal (20.8L)

 - With radiator 16.0 U.S. gal (60.6L)

 - With heat exchanger 13.0U.S. gal (49.2 L)

Max. coolant friction head external to engine 7PSI (48kPa)

Max. coolant pressure (exclusive of pressure cap) 40 PSI (276kPa)

Max. static head of coolant above engine crank centerline 46ft. (14.0m)

Standard thermostat (modulating) range 180~202 °F (82~ 94 °C)

Min. allowable pressure cap7.0PSI (48.2kPa)

Max. coolant temperature 205 °F (96°C)

Max. top tank temperature 212 °F (100°C)

Min. top tank temperature 160 °F (71°C)

Max. allowable top tank temperature for standby / prime power 220/212°F (104/100°C)

Min. recommended top tank temperature 160 °F (71°C)

Min. coolant expansion space 5 % of system capacity

Min. coolant makeup capacity 1.1 U.S. gal (4.2L)

Max. raw water pressure at engine outlet 15PSI (103kPa)

Max. inlet restriction at raw water pump 10in.Hg (34kPa)

Max. raw water pump initial suction lift3.05 ft. (10m)

Min. raw water pipe size 2 in. (51mm)

Allowable pressure drop across keel cooler 4PSI (28kPa)

 

LUBRICATION SYSTEM

Oil Pressure @ idle speed min. 15PSI (103kPa), @ Governed Speed 35~50 PSI (241~345kPa)

Max. allowable oil temperature 250 °F (121°C) 250 ( 121 )

Oil pan capacity - low / high 7.5/9.5 U.S. gal. (28.4/36.0L)

Total system capacity 10.2 U.S. gal. (38.6L)

 

FUEL SYSTEM

Type injection system direct injection Cummins PT

Max. allowable restriction to fuel pump

 -- With clean fuel filter 4.0in.Hg (13.5kPa)

 -- With dirty fuel filter 8.0in.Hg (27.1kPa)

Max. allowable head on injector return line

 -- With check valve 6.5 in.Hg (22.0kPa)

 -- Without check valve 2.5 in.Hg (8.5kPa)

Min. fuel supply line size 0.625in. (16mm)

Min. fuel return line size 0.5in. (13mm)

Max. fuel pump supply 69 U.S.gal/h (261L)

Fuel rail pressure 184 PSI (1271.5kPa)

Max. fuel temperature 160°F (71°C)


Open type Cummins genset


3. Original Stamford alternator HCI444D1

Stamford Alternator is made in complying to the norms: BS EN60034/ BS 5000/ IEC34 etc.

Excitation: Brushless self-excited. AVR controlled.

4. SmartGen controller 6110

SmartGen Control Module 6110: Stillage mounted control panel incorporating an engine control module. Off- Auto- Manual control is selected, via push buttons on the front panel.

Readouts of the Module:

Generator Voltage;

Generator Current;

Generator Frequency;

Engine speed;

Oil Pressure;

Engine coolant temperature;

Engine Hours Run.

Shutdown protection is provided for:

Low Oil Pressure;

High Engine Temperature;

Over and Under Speed;

Emergency Stop;

Failure to start.

 

5. Supply Key Services Parts:                                                                                        

Oil Filters

Fuel filters                                                                                                                         

Fuel Water separators                                                                                                     

Air Filters

AVR                                                                                      

Starter Module

 

We have focused on high quality product for more than 43 years, our genset has sold to all over the world every year and get good feedback from customers. If you are have purchase plan of generator recently, welcome to contact us by email (sales@dieselgeneratortech.com) with your order details, we will give your the best price according to your details.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz