Skip to main content

Archive

Show more

High quality 220kw Cummins diesel generator set

220KW Cummins silent diesel genset is produced by Jiangsu Starlight factory. It it soundproof, rainproof type, equipped with Cummins diesel engine NT855-GA, alternator Stamford HCI444D1 and control panel SmartGen 6110.

 

1. Description/technical specification

Genset model: XG-220GF

Genset Output: 275KVA/220KW

Voltage output: 400/230VAC ( can also made as you need)

Frequency: 60Hz

Power factor: 0.8 lagging

Operating mode:Standby power

Mounting: Skid base with anti-vibrating mountings

Country of origin: China

Certificate: ISO, CE

Fuel tank: The set comes with high capacity base integral fuel tank complete with a fuel gauge

The period of validity of the warranty for 220KW Cummins silent genset is 12 months or 1000 run hours whichever comes first after delivery, installed and accepted and commissioned at the final destination.

Supply together with detailed user manual, engine parts catalog, maintenance & repair manual etc.


 Starlight diesel genset


2. General diesel engine data

Engine model: CCEC Cummins NT855-GA

Engine output power: standby power 257kw

Aspiration: Turbocharged

Cylinders: 6

Speed: 1800 r/min

Displacement: 14L

Bore x stroke: 140x152mm

Fuel System: Cummins PT

Fuel consumption: 100%: 59.4L/h, 75%: 45.5L/h, 50%: 32.3L/h

Standard: ISO3046

All data is based on :

Engine Operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer, fan, and optional driven components.

 

EXHAUST SYSTEM

Maximum Allowable Back Pressure: 3.0in.Hg (10kPa)

Standard Exhaust Pipe Diameter: 5.0 in. (127mm)

AIR INDUCTION SYSTEM

Maximum Allowable Intake Air Restriction

With Clean Filter Element: 15 in. H2O (3.74kPa)

With Dirty Filter Element: 25in. H2O (6.22kPa)  

Minimum Dirt Holding Capacity: 25 g/CFM ( 53g/L/s )

Maximum Allowable Intake Air Temperature ∆T: 30°F (17°C)

 

COOLING SYSTEM

Coolant capacity - engine only 5.5 U.S. gal (20.8L)

 - With radiator 16.0 U.S. gal (60.6L)

 - With heat exchanger 13.0U.S. gal (49.2 L)

Max. coolant friction head external to engine 7PSI (48kPa)

Max. coolant pressure (exclusive of pressure cap) 40 PSI (276kPa)

Max. static head of coolant above engine crank centerline 46ft. (14.0m)

Standard thermostat (modulating) range 180~202 °F (82~ 94 °C)

Min. allowable pressure cap7.0PSI (48.2kPa)

Max. coolant temperature 205 °F (96°C)

Max. top tank temperature 212 °F (100°C)

Min. top tank temperature 160 °F (71°C)

Max. allowable top tank temperature for standby / prime power 220/212°F (104/100°C)

Min. recommended top tank temperature 160 °F (71°C)

Min. coolant expansion space 5 % of system capacity

Min. coolant makeup capacity 1.1 U.S. gal (4.2L)

Max. raw water pressure at engine outlet 15PSI (103kPa)

Max. inlet restriction at raw water pump 10in.Hg (34kPa)

Max. raw water pump initial suction lift3.05 ft. (10m)

Min. raw water pipe size 2 in. (51mm)

Allowable pressure drop across keel cooler 4PSI (28kPa)

 

LUBRICATION SYSTEM

Oil Pressure @ idle speed min. 15PSI (103kPa), @ Governed Speed 35~50 PSI (241~345kPa)

Max. allowable oil temperature 250 °F (121°C) 250 ( 121 )

Oil pan capacity - low / high 7.5/9.5 U.S. gal. (28.4/36.0L)

Total system capacity 10.2 U.S. gal. (38.6L)

 

FUEL SYSTEM

Type injection system direct injection Cummins PT

Max. allowable restriction to fuel pump

 -- With clean fuel filter 4.0in.Hg (13.5kPa)

 -- With dirty fuel filter 8.0in.Hg (27.1kPa)

Max. allowable head on injector return line

 -- With check valve 6.5 in.Hg (22.0kPa)

 -- Without check valve 2.5 in.Hg (8.5kPa)

Min. fuel supply line size 0.625in. (16mm)

Min. fuel return line size 0.5in. (13mm)

Max. fuel pump supply 69 U.S.gal/h (261L)

Fuel rail pressure 184 PSI (1271.5kPa)

Max. fuel temperature 160°F (71°C)


Open type Cummins genset


3. Original Stamford alternator HCI444D1

Stamford Alternator is made in complying to the norms: BS EN60034/ BS 5000/ IEC34 etc.

Excitation: Brushless self-excited. AVR controlled.

4. SmartGen controller 6110

SmartGen Control Module 6110: Stillage mounted control panel incorporating an engine control module. Off- Auto- Manual control is selected, via push buttons on the front panel.

Readouts of the Module:

Generator Voltage;

Generator Current;

Generator Frequency;

Engine speed;

Oil Pressure;

Engine coolant temperature;

Engine Hours Run.

Shutdown protection is provided for:

Low Oil Pressure;

High Engine Temperature;

Over and Under Speed;

Emergency Stop;

Failure to start.

 

5. Supply Key Services Parts:                                                                                        

Oil Filters

Fuel filters                                                                                                                         

Fuel Water separators                                                                                                     

Air Filters

AVR                                                                                      

Starter Module

 

We have focused on high quality product for more than 43 years, our genset has sold to all over the world every year and get good feedback from customers. If you are have purchase plan of generator recently, welcome to contact us by email (sales@dieselgeneratortech.com) with your order details, we will give your the best price according to your details.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...