Skip to main content

Archive

Show more

Starlight Power Sold Canopy 2250kva MTU engine generator

Recently, Starlight Power signed a contract with an engineering construction company for 1800kw MTU silent diesel generator set. Thanks for the customer's support in this cooperation.


The engineering construction company was founded in 1993, business scope includes construction engineering, municipal engineering, mechanical and electrical equipment installation, decoration engineering contracting, etc. Over the past 43 years, Starlight Power company has always provided good product and technical support and good after-sales service for our customers. 

 

The 1800KW MTU silent genset has reasonable structure design, modular structure design, convenient maintenance, excellent engine load response characteristics, and meets the national emission standard. There is no need to do additional purification and dust removal treatment. The noise level is 80dB @7m, which meets the National noise index. Our technicians will be responsible for installation, commissioning and technical operation training.


 1800KW silent diesel generator set


The supply list of 1800KW MTU silent diesel generator set includes 1800kw genset, MTU engine, Marathon alternator, Deep Sea controller, rubber shock absorber, water tank( 50℃), 200AH battery(4 pcs), 220V battery charger, silencer, bellows, Oil water separator, water jacket heating equipment(2KW), silent case, fuel tank 2000L, output cabinet switch, ABB circuit breaker, accessories: instrument, transformer, etc.

 

Technical specifications for silent type 1800KW MTU diesel generator set

Manufacturer: Jiangsu Starlight Electricity Equipments Co.,Ltd.

Genset model: XG-1800GF

Type: silent type ( weather & soundproof)

Prime power: 1800KW

Rated voltage: 230/400V

Rated frequency: 50Hz

Rated current: 3240A

Overall size: 9x2.6x2.78m

Net weight: 15000kg

 

The special treatment technology of MTU/DDC on cylinder block can completely avoid the influence of high sulphur content of domestic diesel oil on diesel engine. It also ensures that in a large number of practical use in China, the MTU continuous operation failure time record is more than 10 times higher than that of other international advanced EFI diesel engines.

 

MTU/DDC's unique electronic management system can detect the hidden trouble of diesel engine all the time. It can show 385 fault codes.The type of fault diagnosis is several times higher than that of other international advanced EFI diesel engines.

 

Max. availability, minimum downtime and max. efficiency in 24/7 continuous use. Compared with the EU stage III A / EPA Tier 3, the series 1600, 2000 and 4000 save 5% fuel and the engine's life is up to 20%.

 

Technical specifications for MTU diesel engine

Manufacturer: MTU

Engine model: 16V4000G23

Engine power: prime/standby: 1980KW/2475KW

Number of cylinder: 16

Capacity of oil: 300L

Fuel consumption: 192g/KW.h

 

Technical specifications for Marathon alternator

Manufacturer: Marathon

Model: MX-1800-4

Rated speed: 1500rpm

Type: Brushless self excitation

Bearing: single bearing

Alternator efficiency: above 95%

Protection level: IP23

Insulation class:H

 

Technical data for Deep Sea controller

Manufacturer: Deep Sea    make: UK

Model: DSE7320

  

Starlight power generator set power range is from 20KW to 2750KW, if you interested in diesel generator set, welcome to contact us by email sales@dieselgeneratortech.com.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...