Skip to main content

Posts

Archive

Show more

Generator Training

50KW Silent Diesel Generator-Starlight Power

  Recently, Starlight signed a contract of 2 sets of 50KW diesel generator set with Beijing Gu Hong Technology Co., Ltd. Beijing Gu Hong Technology Co., Ltd. Was set up in 2005. 50KW silent diesel genset purchased the customer is equipped with SDEC( Shangchai) H series diesel engine. The engine is a world-class power platform built by Shangchai company according to the characteristics of market demand at home and abroad, referring to the mature technology of international advanced engine, jointly designed with Ricardo of UK, using CPDP development process and SAIC MOTOR manufacturing standard. This series of engines have the characteristics of compact structure, wide range of power, high reliability, good economy and low vibration and noise. In addition, the generator set is equipped a silent rain proof canopy cabinet, which can be directly  outdoor used, and ensure that the generator set is free from the influence of wind, rain, dust and mosquitoes. More importantly, the nois...

Starlight Power Wishes Everyone Merry Christmas

2000KW diesel generator set specifications

  Today Starlight Power shares the structure and design of 2000KW diesel generator set, which also supplied by Starlight Power. 1.The generator set can start and operate with load quickly. In the case of unattended operation, the unit can start automatically within 10 seconds after receiving the start command. Under normal site condition, the success rate of one-time self starting of the unit shall not be less than 99%. 2.The start-up battery can restart after failure starting 5s, and can provide six consecutive starts without affecting the use of the start-up battery in the future. The starting battery has redundant starting system. Provide two sets of battery device: one is static charging device after long-term shutdown of the unit(automatic battery charger); another is charger device during unit running(maintenance free battery). When battery charger has fault, The genset control unit can send out alarm signal. 3.Automatic start-up device can send out self-start command after m...

1500KVA Diesel Generating Set Electric Generator

The reason of electric generator tripping

  Tripping phenomenon A.If diesel genset operates under rated conditions for a few minutes, the automatic air switch trips, after recloses, then trips a few minutes later with a burning odor. The cause: The main contact of the automatic air switch is not well contacted or the spring pressure is insufficient. and the lead-out wire of the switch is not well contacted. The above two reasons will increase the contact resistance of the main circuit of the automatic air switch and cause serious fever, which will lead to the action of the thermal release and lead to wrong tripping. Methods of resolution: At this time, we should clean the main contacts of the automatic air switch and flatten them with a fine file or fine sandpaper; Adjust contact spring pressure to make good contact; clean contacts, apply conductive paste if necessary, and lock connection screw. B.Diesel generator trips immediately after connecting load. After the unit starts, the generator terminal voltage is ...