What are the advantages of mobile trailer generator sets?

  The mobile trailer generator set adopts a leaf spring suspension structure with reasonable node selection, high strength and good rigidity. The power station is easy to move, flexible to operate, and has good sealing and safety. And equipped with hand brake, air brake, rear tail lights and other systems, in line with road driving requirements. Widely used in construction sites, highway, railway construction and temporary locations where electricity is used. So what are the advantages of mobile trailer generator sets? Advantages of mobile trailer generator sets : 1. Active hook traction, 180 ° turntable, flexible steering; 2. The round steel pipe is welded with straight-through axles, and is equipped with a leaf spring suspension structure; 3. The four corners of the frame are provided with mechanical support devices; 4. The vehicle is equipped with steering and tail lights; 5. The size of the car box is determined according to the specifications, and the operator can walk around,...

Diagnosis The Inaccurate Fuel Supply Time of Diesel Generator Sets

After the diesel fuel of the diesel generator set is injected into the cylinder, it is mixed with the air to form a combustible mixture. In order to ensure that the combustible mixture is fully burned, and the combustion pressure reaches a large value at a certain moment after the top dead center, to ensure the diesel generator set diesel engine works normally. When the piston reaches a certain angle before the compression top dead center, the fuel injection pump must supply fuel to the fuel injector. The fuel supply time is expressed by the crankshaft rotation angle, which is called the fuel supply advance angle. The fuel supply advance angle is an important factor that affects the combustion process of the diesel engine. A good fuel supply advance angle makes the power and economy of the   diesel generator set   better. In the process of use, due to the wear of the relevant parts or the change of the relative position, the fuel supply advance angle will change. When it excee...

Do you know how to adjust the oil supply of the Cummins diesel generator set

Do you know how to adjust the oil supply of the Cummins diesel generator set? If the oil supply of each cylinder of the Cummins diesel generator set is uneven (some cylinders are too large, some cylinders are too small), it will directly affect the stability of the engine operation. The fuel injection pump can be removed for inspection and adjustment on the test bench. However, if a test stand is not available, it is necessary to check for uneven oil supply and also to roughly check the oil supply of the suspect cylinder. Check the adjustment method and prepare two glass graduated cylinders for later use. If you can't find the graduated cylinder at this point, you can use two identical vials instead, and in the case of an oversized (or undersized) fuel supply, remove the high-pressure fuel line fitting that connects to the 1-cylinder injector. Remove the high-pressure pipe joint connecting the first cylinder with normal fuel supply and the fuel injector, and insert the two fuel pip...

Full New Diesel Generator 250KW China Manufacturer

Buying a Standby Generator , what should you know?

  Power outages can happen at any time for a variety of reasons, from simple electrical failures to severe weather to natural disasters. Having an emergency backup power source like a Standby Generator   should be very important. A Standby Generator can keep you comfortable and safe. 5 characteristics of Standby Generator s to be aware of. 1. Automatic shutdown Don't underestimate this important safety feature of a large-capacity Standby Generator . If the device starts to overheat, the automatic shutdown will turn it off. Likewise, generators with this switch will automatically turn on in the event of a power outage, so you don't have to manually turn on the generator yourself in the dark. 2. Shell type Standby Generator s   are usually placed outside your house and need to be made of sturdy materials that can withstand years of use and severe weather or environmental damage. Look for brands with steel casings or corrosion-resistant composites. If you are concerned about...

High Quality Diesel Generator Set Manufacturer

Nowadays, there are many generator set manufacturers. How to select high-quality generator set manufacturers is very important. Let me tell you how to choose high-quality generator manufacturers. You can refer to it when purchasing generator sets. 1. Price factor The   diesel generator sets price   directly affects the cost of the company, and the price that is too high or too low can not be taken. If the price of the generator set is too high, it will certainly harm the interests of consumers. If another manufacturer is much lower, then this situation is nothing more than to confuse the false with the true. If it is a genuine configuration, the price of the same generator set and the same power should not be very different. Not all machines have the same load, that is, 2-3 times the total. The load of the top three machines is mainly considered. Of course, this situation refers to the situation that someone can start the machine one by one. If you want to start at the sa...

50KW Yuchai Diesel Power Generating Set with CE ISO certificate

How to maintain the mobile trailer generator set

  Diesel generator sets are limited to the following maintenance methods: Check the four-leakage phenomenon, surface, starting battery, engine oil and fuel oil of the unit; Clean and improve the environment of the computer room, and replace the three filters regularly; Carry out no-load maintenance every month, and carry out maintenance of loading and test machine every six months; Use power monitoring to observe power quality parameters in real time. Limitations of existing maintenance methods: The load test in the existing maintenance is only the load test of the existing back-end electrical equipment, which has certain risks and low power; There is no scientific basis for replacing the three filters or undergoing major repairs; After replacing the three filters or undergoing major repairs, there is no special load for loading test machine, and it is not clear whether the expected purpose can be achieved; A large amount of carbon deposits produced by no-load test machine and low-...

Installation skills of mobile generator sets

  Mobile generator set, also known as trailer generator set, can be moved freely and is suitable for large and unfixed workplaces, such as construction sites, large-scale breeding sites, field mining, media outdoor interviews, etc., and can be used as the main power source It can also be used as a backup power supply. Its cover is made of high-quality galvanized sheet, which has the characteristics of corrosion resistance and good sealing. The windows and doors on all sides are supported by automatic hydraulic pressure, which is easy to open. The chassis wheels can be customized according to user needs. The Trailer Generator   is mainly installed on a movable platform such as a car, a trailer or a trailer. The installation and layout requirements are as follows. 1. The platform should be located in a solid, flat and dry place. Under normal circumstances, the platform and the ground do not need to take fixing measures, but the chassis of the unit should be stable. 2. Comprehens...

Full New 600kva Diesel Generators Powered by CCEC Cummins Engine QSK19-G4

Three Tips for a Successful Installation of a Diesel Generator Set

  What can it cost to set up a   Diesel Generator Set ? That is always the first issue our clients ask. There are lots of things that will dictate the price of an installment, and it is important your installer is acquainted with these variables. Where will the generator be found? Can there be landscaping required? The number of feet of conduit will be required? An preliminary site-walk and load observation are a first measure. Our qualified local electricians can collect onsite information for suitable load sizing, inspection prospective installation places, and gather any information required to permit us to create a proposal for your job. Different towns have very different procedures and requirements. When it's codes, structure, transport, flood zones or after-hour job demands - these affect virtually every aspect of a project deadline. There are many factors that affect permit approvals. We are experienced in dealing with municipalities throughout the nation, so we are ab...

What are the Precautions for the Start-Up and Use of Diesel Generator Sets?

  As a   Diesel Generator Manufacturer , share with you. Before starting the diesel generator set, we should first check whether all the switches and corresponding conditions of the generator set are ready, and start the engine set when the conditions are all feasible. Diesel Generator 1. The continuous working time of each start of the generator set should not exceed 10S, and the interval between two starts should be more than 2min to prevent the armature coil from overheating and burning out. If it fails to start successfully three times, you should find out the reason before starting. 2. When you hear the drive gear rotating at high speed and cannot mesh with the ring gear, you should quickly release the start button. After the starter stops working, start the second time to prevent the drive gear and the flywheel ring from colliding with each other and damage .  3. When using diesel generators to supply power in cold areas, switch to antifreeze oil; when starting, use...

STARLIGHT SILENT DIESEL GENSET

  STARLIGHT SILENT DIESEL GENSET Starlight silent diesel generator adopts vibration isolation, noise reduction, sound insulation, sound absorption, fireproof, high temperature resistance, rainproof, anticorrosion and so on noise reduction technical measures, which greatly reduces its noise index. This series of genset has remarkable low noise performance, multi-layer shielding impedance mismatch type soundproof cover, reducing the impact of noise on users. Starlight silent generator noise level can reach 75 dB, with low fuel consumption, reliable performance and easy operation features. Starlight silent gensets   are manufactured by adopting international advanced technology of generating sets. The gensets we manufactured comply with national standards GB/T2820-1997 or GB12786-91 and also have been put into the market. This series of gensets have significant low noise performace, multi-layer shieding impedance mismatch type acoustic shield, which greatly reduce the influence o...

New Genset 375KVA Diesel Generating Set with Yuchai Engine

Starlight Engineer Guides the User to Operate Ricardo Diesel Generator

24KW 30KVA WEICHAI DIESEL GENERATOR SET

  24KW 30KVA WEICHAI DIESEL GENERATOR SET Diesel Generator Set Data Set Type: XG-24GF Output Power: 24KW/30KVA Rated Current: 43.2 ( A ) Rated Frequency: 50 ( Hz ) Start-up time: 5 ~ 6 ( s ) Weichai Diesel Generator Set   Power Factor: 0.8 ( Lag ) Rated Voltage: 400/230 ( V ) Starlight Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS a...