Diesel Generator with Stamford Alternator and InteliLite Controller



As the leading manufacturer of diesel generator, we are really professional in distinguishing the high quality alternator and controller. Thus, in this post, we are going to introduce Stamford generator and InteliLite controller.






Stamford Generator (U.S.A)
Starlight Stamford generator series adopt the Stamford alternators produced by Cummins Generator Technologies (China) Co.,Ltd. (formerly as Wuxi New Era Ac Generator Co.,Ltd.).The company is the only wholly owned enterprise of cummins generator technology system in China, wiht the first phase of investment of 17.6 million dollars.Founded in February 1996, it was officially opened in November 1997.The current annual production capacity is 50000 sets of generators.

Cummins generator technology system is leader of AC generator technology in the world, with a global sales and service network In Britain, the United States, China and India, it all has production plants, and 50 years of its experience can successfully meet customer needs.Wuxi plant produces the Stamford alternator completely according to the design and process standards of cummins generator technology system. Product design, material, production and test are directly managed and controlled by the British personnel.Small volume, light weight, advanced technology, and reliable performance are all important characteristics of Stamford generators.



Stamford generators produced by Cummins Generator Technologies (China) Co.,Ltd. can be matched with all diesel engines in the world, such as cummins, perkins, VOLVO, MTU, Deutz, Caterpillar and domestically produced 95, 130, 135, 130, 190 series diesel engines, etc.Various series products are successfully supplied to manufacturers in complete gensets, and they are widely used in railway, ship, post and telecommunication, military industry, oil field, traffic, high-rise buildings, refrigerated container, etc. Cummins Generator Technologies (China) Co.,Ltd.have these generator series: BC16, BC18, UC224, UC274, HC4 and HC5, LV6, HC7.The scope of power is: 6.5 KW - 1600 KW.

Brief introduction of InteliLite controllers:
InteliLite COMAP controllers adopt micro processing technology. Through the algorithm writing software which is suitable for gensets, they have improved the control over the output voltage, phase voltage, active power and reactive power of the sets.

The AMF series InteliLite controller is a single genset used as a backup power supply, which meets the requirements of most of the detection system of mains supply faults, including the mediator connection.AMF25 module is featured by an extensible support for efi engine.Being easy to use and install, its a typical configuration in advance for applications, which is is available just like the configuration for the special applications defied by users.



Technical parameters of Czech InteliLite AMF25 control modules

1.The general Chinese/English version of AMF25C is a single generator controller with three-phase mains detection;

2. Self start-up sets for mains supply faults;

3. and control ATS switch;

4. With alternating current (ac) display and protection;

5. Display and protection of analog of three-channel and speed sensor;

6. Can be monitored directly by a computer;

7. support Modbus monitoring;

8. Support remote monitoring of data machine

Operation Interface of Intelilite Controller
Button:

1. Operation mode of forward choosing gensets in cycle (closemanualautomatictesting)

2. Operation mode of backward choosing gensets in cycle (close-manual- automatic- testing)

3. HORN RESET Alarm and buzzer are all-clear

4. FAULT RESET confirmation of FAULT and alarm

5. START generator start-up

6. STOP genset stop

7. MCB ON/OFF manual open/close of breakers of mains supply circuits

8. GCB ON/OFF manual open/close of breakers of generating circuits

9. PAGE cyclical selection of display mode (measure-adjust-history records)

10.Select setting-poinst, select screen or increase the value of the setting point

11.Select setting-poinst, select screen or decrese the value of the setting point

12, ENTER Confirmation of value of setting points



indicating lamp:

13. Existence of mains supply:if the mains supply exists and its within the scope of the limit, the green light will be on.

14.Faults of mains supplywhen the mains supply fails, the red light begins to shine. After pressing the FAULT RESET button, the light becomes stable (if fault warning still exists) or goes out (if alarm is all-clear).

15. Existence of power voltage:if the power voltage exists and its within the scope of the limit, the green light will be on.

16Faults of gensets: when the gensets fail, the red light begins to shine. After pressing the FAULT RESET button, the light becomes stable (if fault warning still exists) or goes out (if alarm is all-clear).

17, GCB closed: if the breaker of the generator circuit is closed, the green light will be on. Driven by GCB feedback signals.

18, MCB closed:If the breaker of the mains supply is closed, green light will be on. Driven by GCB feedback signals.


Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...