Skip to main content

Archive

Show more

Diesel Generator with Stamford Alternator and InteliLite Controller



As the leading manufacturer of diesel generator, we are really professional in distinguishing the high quality alternator and controller. Thus, in this post, we are going to introduce Stamford generator and InteliLite controller.






Stamford Generator (U.S.A)
Starlight Stamford generator series adopt the Stamford alternators produced by Cummins Generator Technologies (China) Co.,Ltd. (formerly as Wuxi New Era Ac Generator Co.,Ltd.).The company is the only wholly owned enterprise of cummins generator technology system in China, wiht the first phase of investment of 17.6 million dollars.Founded in February 1996, it was officially opened in November 1997.The current annual production capacity is 50000 sets of generators.

Cummins generator technology system is leader of AC generator technology in the world, with a global sales and service network In Britain, the United States, China and India, it all has production plants, and 50 years of its experience can successfully meet customer needs.Wuxi plant produces the Stamford alternator completely according to the design and process standards of cummins generator technology system. Product design, material, production and test are directly managed and controlled by the British personnel.Small volume, light weight, advanced technology, and reliable performance are all important characteristics of Stamford generators.



Stamford generators produced by Cummins Generator Technologies (China) Co.,Ltd. can be matched with all diesel engines in the world, such as cummins, perkins, VOLVO, MTU, Deutz, Caterpillar and domestically produced 95, 130, 135, 130, 190 series diesel engines, etc.Various series products are successfully supplied to manufacturers in complete gensets, and they are widely used in railway, ship, post and telecommunication, military industry, oil field, traffic, high-rise buildings, refrigerated container, etc. Cummins Generator Technologies (China) Co.,Ltd.have these generator series: BC16, BC18, UC224, UC274, HC4 and HC5, LV6, HC7.The scope of power is: 6.5 KW - 1600 KW.

Brief introduction of InteliLite controllers:
InteliLite COMAP controllers adopt micro processing technology. Through the algorithm writing software which is suitable for gensets, they have improved the control over the output voltage, phase voltage, active power and reactive power of the sets.

The AMF series InteliLite controller is a single genset used as a backup power supply, which meets the requirements of most of the detection system of mains supply faults, including the mediator connection.AMF25 module is featured by an extensible support for efi engine.Being easy to use and install, its a typical configuration in advance for applications, which is is available just like the configuration for the special applications defied by users.



Technical parameters of Czech InteliLite AMF25 control modules

1.The general Chinese/English version of AMF25C is a single generator controller with three-phase mains detection;

2. Self start-up sets for mains supply faults;

3. and control ATS switch;

4. With alternating current (ac) display and protection;

5. Display and protection of analog of three-channel and speed sensor;

6. Can be monitored directly by a computer;

7. support Modbus monitoring;

8. Support remote monitoring of data machine

Operation Interface of Intelilite Controller
Button:

1. Operation mode of forward choosing gensets in cycle (closemanualautomatictesting)

2. Operation mode of backward choosing gensets in cycle (close-manual- automatic- testing)

3. HORN RESET Alarm and buzzer are all-clear

4. FAULT RESET confirmation of FAULT and alarm

5. START generator start-up

6. STOP genset stop

7. MCB ON/OFF manual open/close of breakers of mains supply circuits

8. GCB ON/OFF manual open/close of breakers of generating circuits

9. PAGE cyclical selection of display mode (measure-adjust-history records)

10.Select setting-poinst, select screen or increase the value of the setting point

11.Select setting-poinst, select screen or decrese the value of the setting point

12, ENTER Confirmation of value of setting points



indicating lamp:

13. Existence of mains supply:if the mains supply exists and its within the scope of the limit, the green light will be on.

14.Faults of mains supplywhen the mains supply fails, the red light begins to shine. After pressing the FAULT RESET button, the light becomes stable (if fault warning still exists) or goes out (if alarm is all-clear).

15. Existence of power voltage:if the power voltage exists and its within the scope of the limit, the green light will be on.

16Faults of gensets: when the gensets fail, the red light begins to shine. After pressing the FAULT RESET button, the light becomes stable (if fault warning still exists) or goes out (if alarm is all-clear).

17, GCB closed: if the breaker of the generator circuit is closed, the green light will be on. Driven by GCB feedback signals.

18, MCB closed:If the breaker of the mains supply is closed, green light will be on. Driven by GCB feedback signals.


Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...