Engga Generator End For Diesel Generator


Starlight Engga Generator EG series uniaxial and biaxial brushless AC generators are designed by guangzhou Engga Generator Co.,Ltd.The scope of its power:40 kw to 3000 kw. Frequency:50 hz or 60 hz. Guangzhou Engga Generator Co.,Ltd. is a sino-foreign joint venture integrated with scientific research, development, manufacturing, sales and specialized management of generators, and it is committed to the development of new energy products and vigorously promoting the industrialization of various specifications of the wind generators and high voltage generators. At present, Engga Generator Co.,Ltd. is one of the most powerful generator manufacturers in the world.





Engga EG series generators have been widely matched with import engines such as those from Volvo, Mitsubishi, cummins, Deutz, MTU, Daewoo, John Deere, MAN and Jones and domestic engines such as SDEC, Jinan Diesel Engine, Weichai, Xichai, Wudong, Deutz, Steyr and Shengdong. It is the right alternator for diesel generator.

As EG generator exports and domestic sales continue to increase, in order to better meet the OEM customers, the company developed the series 160 (power from 16 kw ~ 32 kw) and series 500 (power from 1200 kw to 2000 kw), and it also optimized and improved the original series, which is a full launch of the new series generators with the suffix N.

Advantages of Engga generators:

They adopt registered patent technology, and Engga EG series of generators are significantly enhanced in the mechanical strength and end insulation of the stators, with a improved.overall life.

1) Structure of stator end:

Stator coil end adopt the Class H insulation film and insulating tape to conduct a half-lapped tapping along the wire root for different phase coil end that sticks out of the notch,so as to improve the insulating strength and mechanical strength of the end. The end of the stator and the each bundle of the extended coils are processed, and the end of each bundle of the extended coil get shaped. and then on the stator end of each Engga generator, an insulation end ring is added, and each bundle of the extended coil shaped by the special process will all be effectively fixed on the insulation end ring, which makes the the end coil form an entity with an excellent strength.This effectively prevents and resists the impact of the stator end falling apart caused by because of the sudden loading and short circuit.
Patented rotor coil wires, structure with triple-insulated treatment:

Bottom: lapped tapping of Class H insulation film;

Middle: Insulating-glass wrapping;

Outside: immersion and drying of high quality insulating paint;

Effectively improve the insulation between rotor's different bundles and different layers, and effectively enhance the moistureproof and anticorrosive ability, and also effectively improve the life, reliability, environmental adaptability of the generator accordingly. Especially to adapt to the bad environment such as high heat and humidity, subtropics, island, chemical industry, textile, etc.

Advantages of adoption of patented rotor wire:
If ordinary enameled wires are used to wind the rator, it could easily cause short circuit between bundles and layers which result from the painting cracks and falling off. This kind of fault is a major cause of the damage of a generator. By comparison in said experiment, due to the special structure, the flat copper wires which adopt the amido film half-lapped tapping and glass fiber lapping absolutely will not lead to problems and hidden dangers because of insulation layer during the winding.Improvment in the insulation reliability of EG generator is especially suitable for the bad working environment.

The production technology of the Engga EG generator rotor which adopts the registered patent technology results in a qualitative leap in its reliability and service life:

A. Automatic voltage regulation system:

In the design of the EG series generators, the extension phenomenon due to the high temperature when the flat copper wire of the generator stator is running has already been considered. It adopts the design of sectional supporting block, with sufficient space reserved, so as to prevent the insulation from damages because of the contraction principle of flat copper wire, which could burn generators.

Because there is no consideration of the heat expansion of the rotor winding at work, so other brand generators in the long tiem workload could easily cause the damage to the insulation structure because of the above reasons, thus leading to the generator damage.


Generators use Brushless self-excitation automatic voltage regulation system:

use the fundamental wave and third harmonic at the same time as the excitation power to supply excitation, build stable output voltage with an excellent dynamic performance, give a consideration on the function of built-in sudden loading buffer of the fully plastic-filmed electronic AVR module (LAM) working under bad environment

In addition to the above four advantages, carefully designed EG series also have some other advantages:

1. They adopt backward type high-efficiency cooling fans which greatly reduce the noise of generator during running, with an average running noise decreased by 3-5 db.


2. They use the bearing structure of sealed dust-proof ball bearings which greatly extends the service life of the generator. The design of flange seam allowance under the S.A.E standard and domestic engine connection standard make them easier to connect with imported or domestic engines.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...