Do You Know Active Power and Reactive Power of Diesel Generator Set?

In the AC circuit of the diesel generator set, there are two kinds of electric power supplied by the power source, one is active power and the other is reactive power.

Active power is the electrical power required to keep a consumer operating normally, that is, the electrical power that converts electrical energy into other forms of energy (mechanical, optical, thermal). Various lighting devices convert electrical energy into light energy for people to live and work with. The sign of active power is denoted by P and is expressed in watts (W), kilowatts (kW), megawatts (MW).

Reactive power is relatively abstract, it is used to exchange electric and magnetic fields in the circuit, and is used to establish and maintain the electrical power of the magnetic field in electrical equipment. It does not work externally, but instead transforms it into other forms of energy. For electrical equipment with electromagnetic coils, reactive power must be consumed to establish a magnetic field. Because it does not work outside, it is called "reactive." The sign of reactive power is represented by Q, and the unit is either Var or kVar.

Reactive power is by no means useless power, and it is very useful. The motor needs to establish and maintain a rotating magnetic field to rotate the rotor, thereby driving the mechanical motion. The rotor magnetic field of the motor is established by taking reactive power from the power source. The transformer also needs reactive power to generate a magnetic field in the primary coil of the transformer and induce a voltage in the secondary coil. Therefore, without reactive power, the motor will not rotate, the transformer will not be transformed, and the AC contactor will not pull.

Under normal circumstances, the powered device not only needs to obtain active power from the power supply, but also needs to obtain reactive power from the power supply. If the reactive power in the power grid is in short supply, the power equipment does not have enough reactive power to establish a normal electromagnetic field. Then, the power equipment cannot be operated under the rated condition, and the terminal voltage of the power equipment is lowered. Thereby affecting the normal operation of the electrical equipment. Reactive power has certain adverse effects on supply and use of electricity, mainly in:

1. Reduce the output of the generator's active power.
2. Reduce the power supply capacity of transmission and transformation equipment.
3. This causes an increase in line voltage loss and an increase in power loss.
4. This results in low power factor operation and voltage drop, resulting in insufficient electrical equipment capacity.

The reactive power supplied from the generator and the high-voltage transmission line can not meet the needs of the load, so some reactive power compensation devices should be set in the power grid to supplement the reactive power to ensure the user's need for reactive power. Electrical equipment can operate at rated voltage. This is the reason why the grid needs to install reactive power compensation devices.

Relationship between active power and reactive power of diesel generator

Principle of power generation

Generators are divided into two major categories: DC generators and alternators. The latter can be divided into synchronous generators and asynchronous generators. The most commonly used in modern power stations is synchronous generators. This type of generator is characterized by DC current excitation, which can provide both active power and reactive power to meet the needs of various loads. Synchronous generators are classified into three types: turbine generators, hydroelectric generators and diesel generators according to the different prime movers used. By installing the brushless synchronous alternator coaxially with the diesel engine crankshaft, the rotor of the generator can be driven by the rotation of the diesel engine. By using the principle of 'electromagnetic induction', the generator will output an induced electromotive force, and a current can be generated through the closed load circuit. .

Synchronous generator power calculation

When the terminal voltage of the generator is kept at the rated value and the active power of the output is P, the relationship between the maximum reactive power Q of the allowable output and the active power P is Q=f(P), which is called the output capacity of the generator curve.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Technical Parameters of Boduan 500KW Weichai Generator Set 6M33D572E200

  The 6M33D633E200 diesel engine is a special-purpose diesel engine for land-based power generation in the M33 series. It is a new-structure power generation diesel engine with a centrally - located turbocharger developed by Weichai Power Co., Ltd. in 2016. Continuous Power (COP): The maximum power at which the diesel engine can run continuously under a constant load with no limit on the annual operating hours. It is the ISO standard power. Prime Power (PRP): The maximum power at which the diesel engine can run continuously under variable loads with no limit on the annual operating hours. It is an ISO standard power that allows a 10% overload. Standby Power (ESP): The maximum power in a certain variable - power series that the diesel engine can operate for up to 200 hours per year. It is an ISO standard power with limited fuel consumption.   Operating Conditions and Applications of Baudouin  500KW Weichai Generator Set  Diesel Engine Power Classification Operating Co...

How to know and solve faults of genset voltage transformer

 Today Starlight Power shares the common faults for voltage transformer of diesel generator set. Hope it is helpful to you. 1) The insulation between iron chips is damaged. Fault phenomenon: temperature rises during operation. The possible causes of the failure are: poor insulation between iron chips, bad use of environmental conditions or long-term operation under high temperature, which promote the insulation aging between iron chips. (2) Poor contact between grounding plate and iron core. Fault phenomenon: there is discharge sound between iron core and oil tank during operation. Cause of failure: the grounding plate is not inserted tightly, and the mounting screw is not tightened. (3) The iron core is loose. Fault phenomenon: abnormal vibration or noise during operation. The cause of failure: the iron core clamp is not clamped, and the iron chip is loose. (4) Turn to turn short circuit of winding. Fault phenomenon: during operation, the temperature rises, there is ...