Do You Know Active Power and Reactive Power of Diesel Generator Set?

In the AC circuit of the diesel generator set, there are two kinds of electric power supplied by the power source, one is active power and the other is reactive power.

Active power is the electrical power required to keep a consumer operating normally, that is, the electrical power that converts electrical energy into other forms of energy (mechanical, optical, thermal). Various lighting devices convert electrical energy into light energy for people to live and work with. The sign of active power is denoted by P and is expressed in watts (W), kilowatts (kW), megawatts (MW).

Reactive power is relatively abstract, it is used to exchange electric and magnetic fields in the circuit, and is used to establish and maintain the electrical power of the magnetic field in electrical equipment. It does not work externally, but instead transforms it into other forms of energy. For electrical equipment with electromagnetic coils, reactive power must be consumed to establish a magnetic field. Because it does not work outside, it is called "reactive." The sign of reactive power is represented by Q, and the unit is either Var or kVar.

Reactive power is by no means useless power, and it is very useful. The motor needs to establish and maintain a rotating magnetic field to rotate the rotor, thereby driving the mechanical motion. The rotor magnetic field of the motor is established by taking reactive power from the power source. The transformer also needs reactive power to generate a magnetic field in the primary coil of the transformer and induce a voltage in the secondary coil. Therefore, without reactive power, the motor will not rotate, the transformer will not be transformed, and the AC contactor will not pull.

Under normal circumstances, the powered device not only needs to obtain active power from the power supply, but also needs to obtain reactive power from the power supply. If the reactive power in the power grid is in short supply, the power equipment does not have enough reactive power to establish a normal electromagnetic field. Then, the power equipment cannot be operated under the rated condition, and the terminal voltage of the power equipment is lowered. Thereby affecting the normal operation of the electrical equipment. Reactive power has certain adverse effects on supply and use of electricity, mainly in:

1. Reduce the output of the generator's active power.
2. Reduce the power supply capacity of transmission and transformation equipment.
3. This causes an increase in line voltage loss and an increase in power loss.
4. This results in low power factor operation and voltage drop, resulting in insufficient electrical equipment capacity.

The reactive power supplied from the generator and the high-voltage transmission line can not meet the needs of the load, so some reactive power compensation devices should be set in the power grid to supplement the reactive power to ensure the user's need for reactive power. Electrical equipment can operate at rated voltage. This is the reason why the grid needs to install reactive power compensation devices.

Relationship between active power and reactive power of diesel generator

Principle of power generation

Generators are divided into two major categories: DC generators and alternators. The latter can be divided into synchronous generators and asynchronous generators. The most commonly used in modern power stations is synchronous generators. This type of generator is characterized by DC current excitation, which can provide both active power and reactive power to meet the needs of various loads. Synchronous generators are classified into three types: turbine generators, hydroelectric generators and diesel generators according to the different prime movers used. By installing the brushless synchronous alternator coaxially with the diesel engine crankshaft, the rotor of the generator can be driven by the rotation of the diesel engine. By using the principle of 'electromagnetic induction', the generator will output an induced electromotive force, and a current can be generated through the closed load circuit. .

Synchronous generator power calculation

When the terminal voltage of the generator is kept at the rated value and the active power of the output is P, the relationship between the maximum reactive power Q of the allowable output and the active power P is Q=f(P), which is called the output capacity of the generator curve.

Comments

Popular posts from this blog

Yuchai Is Super Confident in Its Innovation

Founded in 1951, with 30 wholly-owned, holding and joint-stock subsidiaries, Guangxi Yuchai Machinery Group Co., Ltd. (hereinafter referred to as the Yuchai Group) is an internal combustion engine manufacturing base with the most complete spectrum of products in the country. In recent years, machinery manufacturing industry has been dropped off influenced by domestic and foreign economic situations, especially domestic overcapacity and unreasonable product structure. Reversely, Yuchai has sold over 3 million engines with the annualized revenues amount to RMB 40 billion. Over the years, as China ’ s largest engine R&D manufacturing base, Yuchai adjusts and optimizes its industrial structure and constantly strengthens its capacity for independent innovation. Therefore, the key technology continues to be the top in the sector for further keeping its own top leader in the industry. Innovation-Driven In 2013, seven world-class diesel-engine products for high-s...

How to Read Alarm Codes From SmartGen Genset Controller

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu, such as SmartGen controller. Features:   1. SmartGen 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 2. SmartGen 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation.  3. SmartGen 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. The alarm of diesel generator controller is not the amount of stop alarm, which does not affect the normal operation of diesel generator. When the alarm occurs, the unit will not stop, and when the alarm conditions do not exist, the amount of warning will automatically disappear.  Today Starlight manufacturer mainly shares alarm codes for diesel generato...

How Do You Check Diesel Consumption In The Diesel Generator Set?

  Diesel generator sets   are crucial assets in various industries, providing backup power during outages or serving as primary power sources in remote locations. With fuel costs being a significant operational expense, monitoring diesel consumption becomes essential for efficiency and cost-effectiveness. Here's a comprehensive guide on how to effectively check diesel consumption in a generator set. Understanding Diesel Consumption Metrics Before delving into the monitoring process, it's crucial to grasp the key metrics associated with diesel consumption: Fuel Consumption Rate: This indicates the rate at which diesel is being consumed by the generator set, typically measured in liters per hour (L/hr) or gallons per hour (GPH). Load Factor: The percentage of the generator's maximum capacity being utilized at any given time. It directly influences fuel consumption, with higher loads resulting in increased fuel usage. Fuel Efficiency: A measure of how effectively the generator...