Skip to main content

Archive

Show more

The Reasons for High Water Temperature in Diesel Generators

The high water temperature of diesel generator set is mainly caused by the following reasons:

1. The diesel generator unit uses hard water for a long time. When the generator unit is used, the water tank will generate temperature, so a large amount of scale will be formed in the water tank and water channels, resulting in poor heat dissipation.

2. There are too many impurities in the water channel between the generator body and the cylinder head, which makes the water circulation not smooth and causes poor heat dissipation.



3. The generator set burns engine oil seriously, resulting in excessive carbon deposition and poor heat dissipation.

4. Improper operation and use of diesel generator. When starting the diesel generator, it is necessary to preheat it for a period of time with the medium and small throttle. Do not suddenly increase the throttle and load, otherwise the diesel generator will work rough and the temperature will increase sharply. Or the long-term overload operation of the diesel generator will also cause the temperature of the diesel generator to be too high.

5. Too late oil supply time causes overheating of diesel generator.

6. Put into full load operation immediately after maintenance, resulting in overheating of moving parts or jamming due to too small fitting clearance.

7. The diesel generator is overheated due to insufficient cooling water.

If the temperature of the generator set is too high, it will reduce the fit clearance, strength and lubrication of the moving parts. In serious cases, it may cause cylinder pulling and shaft holding accidents. Therefore, when the temperature of the diesel generator set is too high, it should be repaired in time to avoid irreparable loss.

Jiangsu Starlight Electricity Equipments Co., Ltd. is an important manufacturer of diesel generators. Starlight generator set manufacturers mainly product and sell diesel generator sets, The power of generator set is 20-3000kw, mobile power station is 24-600kw, emergency diesel generator is 24-3000kw, diesel generator set are engaged in generator set maintenance and after-sales service of generator set accessories at the same time. Welcome to contact us by email sherly@dieselgeneratortech.com if you have purchase plan recently.

Comments

Popular posts from this blog

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz

Silent Cummins 640kw Diesel Generating Sets

Technical data of 800KVA AC diesel generator set The DG Set is skid mounted, directly coupled with Cummins water cooled engine with built in shock absorber for anti vibration. The alternator is Stamford brand with brushless and self excited, with control panel and protection system complete set. Prime power: 640KW/800KVA Standby power:704KW/880KVA Rated voltage: 230/400V Rated current: 1152A Speed/frequency:1500rpm/50Hz ( or 1800rpm/60Hz) Power factory:0.8lag Size: open type genset: 4.2 x1.82x2.25m, silent genset: 6.5 x2.6 x2.78m Net wight: open type genset: 7800kg,   silent genset : 12000kg Technical Data of Diesel Engine Diesel engine brand/model: Chongqing Cummins/ KTA38-G2B( full new) Prime/standby power: 790KW/920KW 4 Stroke Cycle , 60° Vee , 12 Cylinder, Turbocharged &Aftercooled, 1500rpm, 50Hz, bore/stroke: 159/159mm. The Cummins diesel engine is equipped with electronic type governor, over speed shutdown devices to protect against runaway when electronic governor or con...

Guides to Clean VOLVO Diesel Generator Cooling System

VOLVO Engine Cooling System Volvo engine's internal cooling system makes sure the engine works at the right temperature. It is a closed system that must always be filled with a mixture of concentrated coolant and water in order to protect the engine against internal corrosion, cavitation and bursting due to freezing. Coolant of a suitable chemical composition must be used all year round. This also applies in areas where there is never any risk of freezing, to provide the engine of  diesel generator set   with full corrosion protection. The use of anti-corrosion agents alone is not permitted in Volvo Penta engines. Never use water alone as a substitute for coolant. The corrosion protection additives become less effective over time, which means that the coolant must be changed at regular intervals; refer to Maintenance Schedule. The cooling system must be flushed whenever the coolant is changed; Volvo Penta coolants have been prepared to work best ...