The Reasons for High Water Temperature in Diesel Generators

The high water temperature of diesel generator set is mainly caused by the following reasons:

1. The diesel generator unit uses hard water for a long time. When the generator unit is used, the water tank will generate temperature, so a large amount of scale will be formed in the water tank and water channels, resulting in poor heat dissipation.

2. There are too many impurities in the water channel between the generator body and the cylinder head, which makes the water circulation not smooth and causes poor heat dissipation.



3. The generator set burns engine oil seriously, resulting in excessive carbon deposition and poor heat dissipation.

4. Improper operation and use of diesel generator. When starting the diesel generator, it is necessary to preheat it for a period of time with the medium and small throttle. Do not suddenly increase the throttle and load, otherwise the diesel generator will work rough and the temperature will increase sharply. Or the long-term overload operation of the diesel generator will also cause the temperature of the diesel generator to be too high.

5. Too late oil supply time causes overheating of diesel generator.

6. Put into full load operation immediately after maintenance, resulting in overheating of moving parts or jamming due to too small fitting clearance.

7. The diesel generator is overheated due to insufficient cooling water.

If the temperature of the generator set is too high, it will reduce the fit clearance, strength and lubrication of the moving parts. In serious cases, it may cause cylinder pulling and shaft holding accidents. Therefore, when the temperature of the diesel generator set is too high, it should be repaired in time to avoid irreparable loss.

Jiangsu Starlight Electricity Equipments Co., Ltd. is an important manufacturer of diesel generators. Starlight generator set manufacturers mainly product and sell diesel generator sets, The power of generator set is 20-3000kw, mobile power station is 24-600kw, emergency diesel generator is 24-3000kw, diesel generator set are engaged in generator set maintenance and after-sales service of generator set accessories at the same time. Welcome to contact us by email sherly@dieselgeneratortech.com if you have purchase plan recently.

Comments

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz