Introduction of Diesel Generator SmartGen HGM9510 Parallel Control Panel

Today Starlight manufacturer introduces SmartGen HGM9510 Parallel Control Panel of diesel generator set

HGM9510 controller is designed for manual/auto parallel system generators with similar or different capacity. Additionally, it is suitable for single unit constant power output and mains paralleling. It allows automatic start/stop, parallel running, data measurement, alarm protection as well as remote control, remote measurement and remote communication function. It fits with LCD display, optional Chinese, English and other languages interface, and it is reliable and easy to use.

Utilizing the GOV (Engine Speed Governor) and AVR (Automatic Voltage Regulator) control function, the controller is able to synchronize and share load automatically; it can be used to parallel with other HGM9510 controller.

HGM9510 controller also monitors the engine, indicating the operational status and fault conditions accurately. When abnormal condition occurs, it splits bus and shuts down the genset, simultaneously the exact failure mode information is indicated by the LCD display on the front panel. SAE J1939 interface enables the controller to communicate with various ECU (ENGINE CONTROL UNIT) which fitted with J1939 interface.

The powerful 32-bit Microprocessor contained within the module allows for precision parameters measuring, fixed value adjustment, time setting and set value adjusting and etc..Majority parameters can be configured from front panel, and all parameters can be configured by USB interface (or RS485) to adjust via PC. It can be widely used in all types of automatic gen-set control system with compact structure, advanced circuits, simple connections and high reliability.

SmartGen HGM9510 generator controller

Power Supply: DC(8-35)V
Case Dimensions: 266*182*45(mm)
Panel Cutout: 214*160(mm)
Operating Temp. : (-25~+70) °C
Weight: 0.95kg

Performance and Charateristics

1. With ARM-based 32-bit SCM, high integration of hardware and more reliable;
2. 480x272 LCD with backlight, multilingual interface (including English, Chinese or other languages) which can be chosen at the site, making commissioning convenient for factory personnel;
3. Improved LCD wear-resistance and scratch resistance due to hard screen acrylic;
4. Silicon panel and pushbuttons for better operation in high/low temperature environment;
5. RS485 communication port enable remote control, remote measuring, remote communication via ModBus protocol.
6. Fitted with CANBUS port and can communicate with J1939 genset. Not only can you monitoring frequently-used data (such as water temperature, oil pressure, engine speed, fuel consumption and so on) of ECU machine, but also control start, stop, raising speed and speed droop via CANBUS port.
7. Suitable for 3-phase 4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with voltage 120/240V and frequency 50/60Hz;
8. Collects and shows 3-phase voltage, current, power parameter and frequency of Bus/mains.
9. For Bus, controller has loss of phase and phase sequence wrong detection functions; For generator, controller has over voltage, under voltage, over frequency, under frequency, over current, over power, reverse power, loss of phase, phase sequence wrong detection functions;
10. Synchronization parameters: Voltage Difference Between Bus and Mains, Frequency Difference Between Bus and Mains, Phase Difference Between Bus and mains;
11. Multiple running modes in auto state: with load running, off load running, demand parallel running;
12.Ramp on and ramp off function;
a. 3 fixed sensors (temperature, oil pressure and liquid level);
b. 2 configurable sensors can be set as sensor of temperature, oil pressure or fuel level;
13. More kinds of curves of temperature, oil pressure, fuel level can be used directly and users can define the sensor curves by themselves;

14. Precision measure and display parameters about Engine,
Temp. (WT)    °C/°F (unit) both be displayed
Oil pressure (OP)   kPa/psi/bar(unit) all be displayed
Fuel level (FL)   %(unit)
Speed (SPD)   r/min(unit)
Battery Voltage (VB)   V (unit)
Charger Voltage (VD)   V (unit)
Hour count (HC) can accumulate Max. 65535 hours.
Start times can accumulate Max. 65535 times

15. Protection: automatic start/stop of the gen-set, ATS(Auto Transfer Switch) control with perfect fault indication and protection function;
16. All output ports are relay output;
17. Parameter setting: parameters can be modified and stored in internal EEPROM memory and cannot be lost even in case of power outage; most of them can be adjusted using front panel of the controller and all of them can be modified using PC via USB or RS485 ports;
18. Multiple crank disconnect conditions (speed sensor, oil pressure, generator frequency) are optional;
19. Widely power supply range DC(8~35)V, suitable to different starting battery voltage environment;
20. Event log, real-time clock, scheduled start & stop generator (can be set as start genset once a day/week/month whether with load or not);
21. Accumulative total run time and total electric energy of A and B. Users can reset it as 0 and re-accumulative the value which make convenience to users to count the total value as their wish.
22. Can control engine heater, cooler and fuel pump.
23. With maintenance function. Actions (warning, trip and stop, shutdown) can be set when maintenance time out;
24. All parameters used digital adjustment, instead of conventional analog modulation with normal potentiometer, more reliability and stability;
25. IP55 waterproofness level can be achieved with the help of rubber-ring gasket between shell and control panel.
26. Metal fixing clips enable perfect in high temperature environment;
27. Modular design, self-extinguishing ABS plastic shell, pluggable terminal, built-in mounting, compact structure with easy installation;

Starlight Power is authorized as the OEM of SmartGen for generator set. For parallel operation genset, we use SmartGen HGM9510 controller. For common genset, we use HGM6110 control module

Comments

  1. This is truly moving!! The manner in which your vocation began sounds precisely like mine, I'm simply trusting it closures like it and use-roused me to never under any circumstance abandon my objective. Diesel generator

    ReplyDelete

Post a Comment

Popular posts from this blog

Components of Cummins PT Fuel System

When it comes to Cummins generator, it is well known that the gensets have good quality, low fuel consumption, low noise, big output power and reliable performance. The reliable stability, economy, power performance, durability and environmental safety is welcomed by customers. In last article, we talk about CCEC Cummins diesel engines operating principles. Well, in this article, you will learn what are the major components of its PT Fuel System. Fuel System The PT fuel system is used exclusively on Cummins Diesels. The identifying letters, “ PT ” are an abbreviation for “ pressure-time ” . The operation of the Cummins PT Fuel System is based on the principle that the volume of liquid flow is proportionate to the fluid pressure, the time allowed to flow and the passage size through which the liquid flows. To apply this simple principle to the Cummins PT Fuel System , it is necessary to provide: 1. A fuel pump. 2. A means of controlling pressure of

Leroy-Somer Alternator AVR R450

1 - GENERAL INFORMATION of Leroy-Somer Alternator AVR R450 1.1 - Description The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers. - Operating temperature: - 30°C to + 65°C. - Storage temperature: - 55°C to + 85°C. - Shocks on the base: 9 g depending on the 3 axes. - Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g. The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection. 1.2 - Characteristic The connection is realised by “Faston” connectors and the voltage sensing is single - phase. 2 - POWER SUPPLY Both the SHUNT/AREP & PMG excitation systems are controlled by the AVR. 2.1 - AREP excitation system With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit. The first winding has a voltage proportional to the   alternator   main voltage (Shunt characteristic),

New Yuchai engine YC6K600-D30 power for diesel generator 50Hz